A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of APC AP9475, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of APC AP9475 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of APC AP9475. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of APC AP9475 should contain:
- informations concerning technical data of APC AP9475
- name of the manufacturer and a year of construction of the APC AP9475 item
- rules of operation, control and maintenance of the APC AP9475 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of APC AP9475 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of APC AP9475, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the APC service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of APC AP9475.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the APC AP9475 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Inst allation Manual InfraS truXure® Central AP9465 AP9470 AP9475[...]

  • Page 2

    This manual is available in English on the enclosed CD. Dieses Handbuch ist in Deutsch auf der beiliegenden CD-ROM verfü gbar . Este manual está disponible en español en el CD-ROM adjunto . Ce manuel est disponible en français sur le CD-ROM ci-inclus. Questo manuale è disponibile in italian o nel CD-ROM alleg ato. 本マニュアルの日本?[...]

  • Page 3

    Content s InfraStruXure Centra l Installation Manual i Product Description .................. ...................................... 1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Inventory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Re[...]

  • Page 4

    InfraStruXure Centra l Installation Manual ii Initial Configuration............... ....................... ................. 10 Configure the InfraStruXure Central Server . . . . . . . . . . . . . . . . . . . 10 System and Web bro wser prerequisites . . . . . . . . . . . . . . . . . . . . . 10 Configuring the InfraStruXure Centr al server from a re[...]

  • Page 5

    1 InfraStruXure Central I nstallation Manual Product Description Overview Inventory • APC ® InfraS truXure ™ Central se rve r — A 1U or 2U management device. The InfraStruXure Central server works with your APC devices, NetBotz appliances, and other third-party SNMP devices to provide a co mprehensive monitoring solution for your IT environm[...]

  • Page 6

    InfraStruXure Centra l Installation Manual 2 Safety Rack-mounting safety The InfraStruXure Central server is shipped with rack-mounting rails. In stall the rails at the appropriate position in your rack, and mount the unit. If the unit is mounte d in an enclosure instead of an open rack, the maximum ambient temperature in the enclosure should be no[...]

  • Page 7

    3 InfraStruXure Central I nstallation Manual Inst allation Inst allation Instructions This installation guide provides in structions for trained service technicians installing one or more systems in a rack. The provided Rapi dRails rack kit can be installed w ithout tools in any enclosure that has square holes. One rack kit is required for each sy [...]

  • Page 8

    InfraStruXure Centra l Installation Manual 4 RapidRails Rack Kit Content s The RapidRails rack kit includes the following items: • One pair of RapidRails slide assemblies Inst allation T asks T o install a rack kit, perform the following tasks in order: 1. Remove the rack doors. 2. Select a location within the rack. 3. Install the RapidRails slid[...]

  • Page 9

    5 InfraStruXure Central I nstallation Manual Inst al l the RapidRai ls sli de ass emblies 1. At the front of the rack cabin et, position one of the RapidRails slide assemblies so that its mounting-bracket flange fits in one U-space in the rack. The top mounting hook on the slide assembly’ s front mounting bracket flange should enter the top hole [...]

  • Page 10

    InfraStruXure Centra l Installation Manual 6 Inst al l the system in the ra ck 1. Pull the two slide assemblies out of the rack until th ey lock in the fully exte nded position. Lift the system into position in front of the extended slid es (see below). 2. Place one hand on th e front-bottom of the system and the other hand on the back-bottom of th[...]

  • Page 11

    7 InfraStruXure Central I nstallation Manual 6. Press up on the slide release latch at the side of each slide to slide the sy stem completely into the rack. 7. Push in and turn the captive thumbscrews on each side of the front chassis panel to secure the system to the rack. Replace the rack doors See the procedures for replacing doors in th e docum[...]

  • Page 12

    InfraStruXure Centra l Installation Manual 8 Route network cables to the InfraStruX ure Central server and switch (or hub) Overhead rout ing. This section is for InfraStru Xure system installations. 1. Ensure that the APC Shielding Partitions an d Cable Ladders are installed on the NetShelter enclosures and the InfraS truXure PDUs. 2. Run the Cat-5[...]

  • Page 13

    9 InfraStruXure Central I nstallation Manual Connect the InfraStruXure Centra l server to your Public LAN For InfraStruXure system in stallations, connect the Infra StruXure Central server ’ s Gb1 port (S tandard version shown) to any network p o rt on the user ’ s Public LAN, using a network jumper cable, or a standard network cable, if necess[...]

  • Page 14

    InfraStruXure Centra l Installation Manual 10 Initial Configuration Configure the InfraS truXure Central Server T o configure the public LAN network settings on the InfraS truXure Central server for the first time, you must connect to the InfraStruXu re Central server as follows: • Connect the private n etwork port (Gb2) with a computer connected[...]

  • Page 15

    11 InfraStruXure Central Ins tallation Manual Enable Remote Monitoring APC can remotely monitor your InfraStruXure Cent ral server and the devices it manages, and notify you of events via e-mail, pager, or phone. If you decide to use APC’ s Remo te Monitoring Service (RMS), follow these steps:. 1. From the Settings menu, select Server Administrat[...]

  • Page 16

    InfraStruXure Centra l Installation Manual 12 Product Information InfraS truXure Central Front Panel Basic model (front) Item Function  Diagnostic Indicators The four diagno stics indicators on the system fron t pa nel di splay error codes during system startup.  Power-on Indicator , Power Button The power-on indicator lights when the system [...]

  • Page 17

    13 InfraStruXure Central Ins tallation Manual St andard model (front) Item Function  DVD Drive Allows CD/DVD-b ased updates for soft ware and fi rmware. (Not available on the Basic model)  Diagnostic Indicators The four diagno stics indicators on the system fron t pa nel di splay error codes during system startup.  Power-on Indicator , Pow[...]

  • Page 18

    InfraStruXure Centra l Installation Manual 14 Enterprise model (front) Item Function  Power-on Indicator , Power Button The power-on indicator lights when the system power is on. The power-on indicator blinks when the system is not turned on but power is available. The power bu tton controls the power supply output to the system.  NMI Button [...]

  • Page 19

    15 InfraStruXure Central Ins tallation Manual InfraS truXure Central rear p anel Basic model (rear) Item Function  Power Socket Receptacle for power cord.  Mouse PS/2 Mouse port  Kbd PS/2 Keyboard port  USB Ports (2) Used to connect USB 2.0-compliant devices to the system .  Serial 9-pin  Monitor External monitor port  System S[...]

  • Page 20

    InfraStruXure Centra l Installation Manual 16 St andard Model (rear) Item Function  Power Socket Receptacle for power cord.  Mouse PS/2 Mouse port  Keyboard PS/2 Keyboard port  USB Ports (2) Used to connect USB 2.0-compliant devices to the system .  Serial Port 9-pin  Monitor VGA monitor po rt  System Status LED and button The [...]

  • Page 21

    17 InfraStruXure Central Ins tallation Manual Enterpris e Model (rear) Item Function  Serial Port 9-pin  Monitor External monitor port  USB Ports (2) Used to connect USB 2.0-compliant devices to the system .  Gb1 Gigabit Ethernet port for connectin g to the pu bli c LAN.  Gb2 Gigabit Ethernet port for connect ing to a private LAN. ?[...]

  • Page 22

    InfraStruXure Centra l Installation Manual 18 Specifications InfraStruXure Central server Electrical Input 100 – 240 V AC; 50/60 Hz; 0.7 A to 0.5 A Physical Dimensions (H × W × D) Unit Basic: 4.5 × 48.3 × 54.6 cm (1.7 × 19 × 21.5 in) Standard: 4.5 × 48.3 × 54.6 cm (1.7 × 19 × 21.5 in) Enterprise: 7.6 × 48.3 × 68.6 cm (3 × 19 × 27 in[...]

  • Page 23

    19 InfraStruXure Central Ins tallation Manual Appendix A: LED Error Codes Error Code Listing Overview The four diagnostics indicators on the system front panel disp lay error codes during system startu p. The following table lists the causes associated with these codes. Code Causes Possible processor failure. Memory failure. Possible expansion card[...]

  • Page 24

    InfraStruXure Centra l Installation Manual 20 Possible expansion card failure. Other failure. The system is in a normal operating condition after POST .[...]

  • Page 25

    21 InfraStruXure Central Ins tallation Manual Appendix B: Diagnostic Messages Message Listing Overview The system's control panel LCD provides status m essages to signify when the system is operating correctly or when the system needs attention. The LCD lights blue to indicate a normal operatin g condition, and lights amber to indicate an erro[...]

  • Page 26

    InfraStruXure Centra l Installation Manual 22 E1618 PS # Predictive Power supply voltage is out of acceptable range; specified power supply is improperl y instal led or faulty . E161C PS # Input Lost Power source for specified power supply is unavailable, or out of acceptable range. E1620 PS # Input Range Power source for specified power supply is [...]

  • Page 27

    23 InfraStruXure Central Ins tallation Manual E2017 Timer Fail T imer r efresh failure. E2018 Prog Timer Programmable interval timer erro r . E2019 Parity Error Parity error . E201A SIO Err SIO failure. E201B Kybd Controller Keyboard controller failure. E201C SMI Init System management i nterrupt (SMI) initiali zation failure. E201D Shutdown Test B[...]

  • Page 28

    InfraStruXure Centra l Installation Manual 24 W arranties and Policies T wo-Y ear Factory W arranty This warranty applies only to the products you purchase for your use in accordance with this manual. T erms of warranty APC warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase[...]

  • Page 29

    25 InfraStruXure Central Ins tallation Manual IN NO EVENT SHALL APC, ITS OFFICERS, DIRECTORS, AFFILIA TES OR EMPLOYEES BE LIABLE FOR ANY FORM OF INDIRECT , SPECIAL, CONSEQUENTIAL OR PUNITIVE DAMAGES, ARISING OUT OF THE USE, SER VICE OR INST ALLA TION, OF THE PRODUCTS, WHETHER SUCH DAMAGES ARISE IN CONTRACT OR TOR T , IRRESPECTIVE OF F AUL T , NEGLI[...]

  • Page 30

    InfraStruXure Centra l Installation Manual 26 Hospital-grade wiring devices and leakage current protection may be ordered as opti ons on many APC UPS systems. APC does not claim that units with th ese modifications are certified or listed as hospital- grade by APC or any o ther organization. Therefore th ese units do not meet the requirements for u[...]

  • Page 31

    [...]

  • Page 32

    06/2008 990-3321-0 01 *990-1636D-001* APC W orldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways: • V isit the APC W eb site to acce ss documents in the APC Knowledg e Base and to submit customer support requests. – www .apc.com (Corporate Headquarters) Connect to lo[...]