APC SUA1000-BR manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of APC SUA1000-BR, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of APC SUA1000-BR one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of APC SUA1000-BR. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of APC SUA1000-BR should contain:
- informations concerning technical data of APC SUA1000-BR
- name of the manufacturer and a year of construction of the APC SUA1000-BR item
- rules of operation, control and maintenance of the APC SUA1000-BR item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of APC SUA1000-BR alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of APC SUA1000-BR, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the APC service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of APC SUA1000-BR.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the APC SUA1000-BR item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Inst allation and Operatio n Smart- UPS ® SUA1000- BR/SUA1500 -BR 120 V AC Eng lish[...]

  • Page 2

    This manu al and th e safet y guide are avai labl e in Englis h on th e enclos ed CD and the APC W eb sit e, www .ap c.com . Este man ual e o g uia d e se guranç a est ão d isponíve is e m p ortugu ês no CD i nclus o e n o w ebsite da A PC, www .apc .com.[...]

  • Page 3

    1 I ntroduct ion Th e AP C ® by Sch n ei d er Elect r i c Smar t - UPS ® is a hig h pe r fo rmance u ninterruptib le pow er supply (UP S) . It pr ovi d es pr ot e ct i on for el ect r on i c eq ui p m en t fr om ut i li t y po wer bl a ck ou t s , br own ou t s , sa g s , and surge s; smal l utility fluctuations a n d l ar ge d isturba n ces . T [...]

  • Page 4

    2 Conne cti ng Eq uipme nt and P ower to the UP S S M ART -UPS R E AR P ANEL 1. Pl ug in th e battery connector n . 2. Conn ect equ i pmen t to th e UPS. No te : D o no t con nect a las er print er to the UP S. A las er printer d raws si gnificantly m ore po wer than other typ e s of equ ipm e nt and may o verload the UPS . 3. Add an y opti on al a[...]

  • Page 5

    3 B ASIC C ONN ECT ORS Seria l P ort USB Port Pow er man a gem en t soft war e and int er face k i t s can be used w ith t h e U PS. U se o nly in terf ac e ki ts s u pp lied o r app rov ed by APC. Us e the AP C s u pplied ca ble to con nect to th e S eria l Po rt. DO N OT u se a sta nda rd seria l inte rfa ce ca ble sin ce it is inco m patib le w [...]

  • Page 6

    4 On Ba tte ry Wh en th e on bat te r y pow e r LED is lit the UP S is supply in g b att e r y pow er t o t h e c onnected e quipme nt. Whe n o n ba ttery , the U P S so un ds an alar m— four beep s e ver y 30 secon d s. Ove rload The LED il lum inate s a nd the U PS e mits a s usta i n ed al arm to n e w h e n an o v erlo ad co n ditio n oc cu r[...]

  • Page 7

    5 3: U SER C ON FI GURAB LE I TEM S N OTE : S ETTINGS ARE M A D E THROUG H SUPPLIED P OWE R C HUTE SOFTWA RE OR OP TIONA L S MA R T S LOT A CCESS O RY CA RDS . F UNC TI ON F ACTORY D EFAUL T U SER S ELE CT ABL E C HO ICE S D ESCRI PT ION A uto m atic S elf -T est Ev ery 14 d ay s (336 ho urs) E v e r y 7 d a ys (168 ho urs), On Sta rtu p On l y, No[...]

  • Page 8

    6 N OTE : S ET TIN G S AR E M ADE TH RO UG H SU P PLIED P OWER C HUT E SOFTWA RE OR OPTI O N A L S MA R T S LO T A CCESS O RY CA RDS . F UNC TI ON F ACTORY D EFAUL T U SER S ELE CT ABL E C HO ICE S D ESCRI PT ION Shutdown Delay 90 seco nds 0, 90, 180, 270 , 360, 450, 540, 6 30 sec onds Sets the int erv al be tw een th e time wh en the UPS rec eiv e[...]

  • Page 9

    7 4: S TORA G E , M AINT E N AN C E , AND T RAN SPORTIN G Storage Sto r e t he U PS co ve red a nd p os itione d as fo r pro pe r f unc tio ning , i n a co o l, dry locatio n, w ith t he b a t- ter i es full y ch ar g ed. At - 1 5 t o + 3 0 ° C ( +5 to + 8 6 ° F ), ch ar ge th e UPS bat t ery ever y six m on th s. At +30 to +45 ° C ( +86 to + 11[...]

  • Page 10

    8 1500VA Model Step 3 Pu ll t h e b atte r y mo dule ou t of th e co mpa rtmen t un t il th e ba ck of th e modu l e i s f l u sh with th e out er ed g es of t h e UPS . Di scon n ect th e ba tt er y c onn ect or . 1000VA Model Ste p 3 Di scon n ect th e ba tt er y cable t er min al s befor e r e m ovi n g th e ba t t er y mod u l e fr om th e UPS [...]

  • Page 11

    9 R EPLACI NG THE B ATTERY M ODULE To r epla ce th e batt er y m odu l e, rever s e th e dir ect i on s above f or Remo ving the Front Be z e l and Battery Mo dule . Disconnec ting th e Batter y for Tr ansport 1. Sh ut down and d is conn ect an y eq ui p men t att a ched t o th e UPS. 2. Shut dow n and disc onnec t the UP S from ut i lity powe r . [...]

  • Page 12

    10 5: T ROUBLES HOOT IN G Use t h e char t belo w to sol ve min or Smar t- UPS in s ta lla ti on an d oper at i on pr oblem s. Refer t o th e AP C We b s ite, www. a p c . c om , for a s si stan ce wi th com pl ex UPS pr oblem s. P ROBLE M AND P OSSI BL E C AU S E S OLU T ION UPS WILL NOT TURN ON Battery not co nnected prop- erly . Ch e ck th at t [...]

  • Page 13

    11 P ROBLE M AND P OSSI BL E C AU S E S OLU T ION T HE O V ERL OAD LED IS LIT A ND THE UPS EMI T S A SU S T AIN E D AL AR M TO N E Th e U PS i s ove r l oa d e d. The co nnected equi pmen t exceed s the spec ifi ed “max i mum load” as defi ned i n Spe cificat i o ns at th e APC w e b si te , www.a pc. com . Th e al a r m re ma in s on u nt i l [...]

  • Page 14

    12 P ROBLE M AND P OSSI BL E C AU S E S OLUTI O N UTILITY CIRCUIT BREAKER TRI PS Util it y c i r cui t bre a ker trip s dur ing no r mal o pera t ion. Reduc e the load o n t he U PS by unplug ging equipmen t and rese t ting t he circ ui t b reaker (on t he bac k of UPS ) by pressing the plung er in. UPS OPER ATES ON B ATTER Y ALTH OU GH NO RM AL L [...]

  • Page 15

    13 Ser vice If the uni t req ui res se r v ice , do no t retu rn it to t he de ale r . F o llow th es e s tep s: 1. Re vi e w t h e Troubleshoo ting se c tion o f the man ual to elim ina te c ommo n pro b lems . 2. If the prob lem persists, co ntact AP C Custo mer Suppo rt throu gh the APC We b site, www.a pc.c om . a. No te th e mo del numb er a n[...]

  • Page 16

    14 6: R AD I O F REQ UENCY W AR N I NG S AND W AR R ANT Y This de v ice comp lies w ith FCC Par t 15 Clas s A r eq ui reme nt s. Op e r atio n is sub j ect to the fo llow in g tw o conditio ns: ( 1) t his dev ice may n ot c aus e harmf ul inte rfe re n ce and (2) t his de v ice must a ccept an y in t er fer ence r ecei ved, in cl u din g int er fer[...]

  • Page 17

    15 REME DY FOR ANY BRE ACH OF SUCH W ARRANTIES. APC WARRANTIE S RUN ONLY TO PURCHASER AND ARE NOT EXTENDED TO ANY T H IRD PARTIES. IN NO EV EN T SH AL L AP C, IT S OF F ICE RS, D I RE CT O RS, A FF IL I AT ES O R EM PL OY EE S B E LI AB L E FO R ANY FO RM O F IN DI RE CT, S PE C IAL, CO NSE Q UE NT IAL OR P UN IT I VE DAMA GES, ARISIN G OUT OF THE [...]

  • Page 18

    12/20 09 990- 3828[...]