APC SURT8000XLI+LE600I manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of APC SURT8000XLI+LE600I, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of APC SURT8000XLI+LE600I one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of APC SURT8000XLI+LE600I. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of APC SURT8000XLI+LE600I should contain:
- informations concerning technical data of APC SURT8000XLI+LE600I
- name of the manufacturer and a year of construction of the APC SURT8000XLI+LE600I item
- rules of operation, control and maintenance of the APC SURT8000XLI+LE600I item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of APC SURT8000XLI+LE600I alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of APC SURT8000XLI+LE600I, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the APC service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of APC SURT8000XLI+LE600I.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the APC SURT8000XLI+LE600I item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Smart-UPS ® RT Uninterruptible Power Supply SURT 8000/10000 VA 200-240 VAC Tower/Rack-Mount 6U English © 2012 APC by Schneider Electric. APC, the APC logo, Sm art-UPS and PowerChute are owned by Schneider Electric Industries S.A.S., American Power Conversi on Corporation, or affiliated companies. All other trademarks are the property of their res[...]

  • Page 2

    [...]

  • Page 3

    Introduction The APC ® by Schneider Electric Sm art-UPS ® RT is a high-performance, uninterruptible power supply (UPS) that provides protection for electronic equipment from utility power blackouts, brownouts, sags and su rges. The UPS filters small utility line fluctuations an d isolates electronic equipment from large disturbances by internally[...]

  • Page 4

    Hardwiring Wiring must be performed by a qualified electrician. 1. Install a utility circuit breaker in accordance with local electrical codes (see tables below) for input wiring. 2. Switch the UP S input circui t breaker (see A ) and utility circuit breakers OFF. 3. Remove the ac cess panel (see B ). 4. Remove circ ular knoc kouts. 5. Run wires th[...]

  • Page 5

    7. XLI mo del only: For three-phase input, set the Input Phase Selector switch (see C ) to ‘3’. For single-phase input, leave switch in default position of ‘1’. 8. Switch the circuit breakers ON. 9. Check line voltages. 10. Replace the ac cess panel. XLT/XLJ/XLTW M ODELS O UTPUT L1A L2A I NPUT L1 L2 A B XLI M ODEL O UTPUT L1A N1 I NPUT L1 L[...]

  • Page 6

    Installing and Connecti ng the Batteries and Attaching the Front Bezel       4[...]

  • Page 7

    C ONNECTING P OWER AND E QUIPMENT TO THE UPS 1. Hardwire the UPS (see Hardwiring ). 2. Connect equipment to th e UPS (cables not included for XLT/XLJ/XLTW models). 3. Turn on all connected equipm ent. To use the UPS as a m aster on/off switch, be sure that all connected equipm ent is switched ON. 4. Press the button on the front panel to power up t[...]

  • Page 8

    B ASIC C ONNECTORS Serial Port Power m anagement software and inte rface kits can be used with the UPS. Use only inter face kits suppli ed or approved b y APC. Ethernet Port Co nnect the UPS to the network. (Located on th e Network Managem ent Card .) EPO Terminal The o ptional Emergency Power Off (EPO) feature allows connected loads to be immediat[...]

  • Page 9

    O PERA TION F RONT D ISPLAY P ANEL Indicator Description Online The UPS is drawing utility power and performin g double conversion to sup ply power to connected equipm ent (see Troubl eshootin g ). On Battery The UPS is supplying batter y powe r to the connected equi pment. Bypass The UPS is in bypass mode, sending utility power directly to connect[...]

  • Page 10

    Feature Function Normal /Bypass Manually switch connected eq uipment to bypass mode, so that utility power is sent directly to connected equipment. Battery op eration is not available while the UPS is in bypass mode. (See Troubleshooting. ) Cold Start This is not a normal condition. Supply imm ediate battery p ower to th e UPS and connected equipme[...]

  • Page 11

    U SER C ONFIGURABLE I TEMS N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OWER C HUTE SOFTWARE , N ETWORK M ANAG E ME NT CAR D , OPTIONAL S MA RT S LOT A CCESSORY CARDS OR T ERMINA L M ODE . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Automatic Self-Test Every 14 days (336 hours) Every 7 d ays (168 hours), Every 14 days (336 [...]

  • Page 12

    N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OWER C HUTE SOFTWARE , N ETWORK M ANAG E ME NT CAR D , OPTIONAL S MA RT S LOT A CCESSORY CARDS OR T ERMINA L M ODE . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION High Bypass Point +10% of output voltage setting +5%, +10%, +15%, +20% Maximum voltage that the UPS will pass to connec[...]

  • Page 13

    EPO (Emergency Power Off) Option The output power can be disabled i n an emerge ncy by closing a switch connected to t he EPO. Adhere to national an d local electrical codes when wiring. The switch should be connected in a normally open switch contact. External voltage is not required; the switch is driven by 12V internal supply. In closed conditio[...]

  • Page 14

    Terminal Mode to Configure UPS Parameters Terminal Mode is a me nu driven interface that enables enhanced c onfiguration of the UPS. Connect the serial cable to the se rial port on the back of the UPS. 1. Open a term inal program . Exampl e: HyperTerm inal  From the Desktop, go to Start => Programs => Accessories => Com munication =>[...]

  • Page 15

    M AINTENANCE , S ERVICE , W ARRANTY , AND T RANS PORTING Replacing the Battery Module(s) This UPS has e asy to replace, hot -swappable ba ttery m odules. Replacement is a sa fe procedure, isolated from electrical hazards. You may leave the UPS and connected eq uipment on during the procedure. See your dealer or contact APC at the Web site, www.apc.[...]

  • Page 16

    T ROUBLESHOOTING Use the table below to solve minor installation and operation problems. Refer to the APC Web site, www.apc.com for assistance with complex UPS problems. P ROBLEM AND P OSSIBLE C AUS E S OLUTION UPS WILL NOT TURN ON Batteries are not connected properly. Check that the battery connectors ar e fully engaged. button not pushed. Press t[...]

  • Page 17

    15 P ROBLEM AND P OSSIBLE C AUS E S OLUTION BYPASS LED ILLUMINATES The bypass switch has been turned on manually or through an accessory. If bypass is the chosen mode of ope ration, ignore the illuminated LED. If bypass is not the chosen mode of operation move the bypass switch on the back of the UPS, to the normal position. FAULT AND OVERLOAD LED [...]

  • Page 18

    Service If the UPS requires service do not return it to the dealer. Follow these step s: 1. Review the pr oblems di scussed in the Tr oubleshoot ing section of this manual to eliminate common pr oblems. 2. If the pro blem persists, co ntact APC C ustomer Su pport thro ugh the APC Web site, ww w.apc.com .  Note the m odel number of the UPS, t he [...]

  • Page 19

    17 R ADIO F REQU ENCY W ARNINGS This equipment has been tested and found to comply with the li m its for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable pr otection against harmful interf erence when the equipment is operated in a commercial environment. T his equipment generates, uses[...]