Go to page of
Similar user manuals
-
Humidifier
Aprilaire 360
4 pages 0.61 mb -
Humidifier
Aprilaire 558
20 pages 0.24 mb -
Humidifier
Aprilaire 600A
11 pages 0.83 mb -
Humidifier
Aprilaire 1952
12 pages 0.19 mb -
Humidifier
Aprilaire 500
2 pages 0.99 mb -
Humidifier
Aprilaire 360
20 pages 0.4 mb -
Humidifier
Aprilaire 550
20 pages 0.12 mb -
Humidifier
Aprilaire 500
16 pages 0.36 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Aprilaire 110, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Aprilaire 110 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Aprilaire 110. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Aprilaire 110 should contain:
- informations concerning technical data of Aprilaire 110
- name of the manufacturer and a year of construction of the Aprilaire 110 item
- rules of operation, control and maintenance of the Aprilaire 110 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Aprilaire 110 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Aprilaire 110, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Aprilaire service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Aprilaire 110.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Aprilaire 110 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
READ AND SA VE THESE INSTRUCTIONS Owner ’ s Manual For Models 110, 112, 220, 224, 350, 360, 440, 445, 448, 558, 560, 568, 760 & 768 Includes Safety & Operating Instructions and W arranty Information Humidifiers[...]
-
Page 2
T ABLE OF CONTENTS WARNING 120 volts may cause injury from electrical shock. Disconnect power and shut off water supply before servicing. CAUTION Sudden operation may cause personal injury or property damage. Turn humidistat or Humidifier Control to “OFF” or lowest setting before servicing Introduction . . . . . . . . . . . . . . . . . . . . . [...]
-
Page 3
- 1 - Thank you for your recent Aprilaire ® Humidifier purchase. We sincerely appreciate your business and are pleased to add your name to our growing list of customers. With this purchase, you have invested in the highest quality equipment currently available. Research Products Corporation is the largest manufacturer of whole house humidifiers, a[...]
-
Page 4
- 2 - With your purchase of a humidification system, you have invested in a humidifier that operates on the evaporative principle – nature’s own way of adding moisture – and will provide the proper relative humidity all during the heating season. It is very possible that you have questions concerning your humidifier – questions on what it c[...]
-
Page 5
- 3 - Capacity is high because an average home (10,000 cu. ft.) requires the addition of approximately 9 gallons of water per day to maintain 35% relative humidity when the outside temperature is 20°. The smallest Aprilaire Humidifier under most operating conditions, has this humidifying capacity. Trouble-free performance and minimum maintenance a[...]
-
Page 6
TABLE 1 – Operation Guide - 4 - There are two possible modes of operation of your Aprilaire Humidifier Control - Automatic and Manual. An explanation of both follows: Automatic Mode: (Manual Mode-see pg 6) Your Humidifier Control is installed in the cold air return. During the first heating season, your Humidifier Control needs to be set initiall[...]
-
Page 7
- 5 - Your Aprilaire Automatic Humidifier, is a high precision system that will accurately maintain the relative humidity in your home. For every 1° change in outdoor temperature, the control will automatically adjust the indoor relative humidity (RH) by 1 / 2 %. If you would like to determine the RH in your home, follow these steps: 1. Determine [...]
-
Page 8
TABLE 3 – Outdoor-Indoor Relative Humidity - 6 - Manual Mode: (Automatic Mode – see pg 4) Your Aprilaire Humidifier is controlled by a Humidifier Control installed either in the living area or in the cold air return. It is important to anticipate a drop in outdoor temperature and reduce the setting accordingly to avoid excessive condensation. F[...]
-
Page 9
- 7 - V . EFFECT OF W A TER CHARACTERISTICS Your humidifier will operate effectively using either hot, cold, hard or mechanically softened water. Whether to use available tap water, even though it may be quite hard, or chemically softened water, is a common concern to homeowners when installing a humidifier. III. OPERA TING INSTRUCTIONS- 110, 112, [...]
-
Page 10
- 8 - VI. ANNUAL MAINTENANCE VII. ANNUAL SUMMER SHUTDOWN For best performance, we recommend that you replace the water panel evaporator in your Aprilaire Humidifier annually. See individual model instructions for additional maintenance. To purchase a Water Panel: • Call the installer of your Aprilaire Humidifier. This information is often found o[...]
-
Page 11
- 9 - NOTE: Periodic inspection and preventive maintenance of your total heating system is important for efficient and safe operation. Your heating contractor should include humidifier service at the same time. All models, except No’s. 448 and 445, are equipped with an in-line water strainer and orifice as shown below. These parts should be inspe[...]
-
Page 12
- 10 - 1. Note Humidistat setting and turn dial to the “off” position. 2. Disconnect electrical power and turn off water supply. 3. Disconnect: a) 120 volt electrical service. b) Copper water supply line (1) & feed tube (2). c) Drain line. d) 24 volt leads. 4. Turn two swing locks (3), one at either side of lower housing off humidifier flan[...]
-
Page 13
- 11 - 1. Note Humidistat setting and turn dial to the “off” position. 2. Turn off water supply and turn down humidistat. 3. Remove three “Z” clips (1) that hold top half of unit to furnace plenum. 4. Slide off four closure clips (2 & 3) that hold two halves of unit together. 5. Loosen compression fitting (4) on copper feed tube (6) and[...]
-
Page 14
- 12 - 1. Note Humidistat setting and turn dial to the “off” position. 2. Disconnect electrical power and turn off water supply. 3. Remove screws of the inlet grille (1). The grille can now be removed from the metal housing (8). 4. Lift the complete plastic framed evaporative section out of the humidifier housing. 5. To remove the distribution [...]
-
Page 15
- 13 - MAINTENANCE INSTRUCTIONS for APRILAIRE HUMIDIFIER MODEL 440 CAUTION! Sudden operation may cause personal injury or property damage. Turn humidistat to “off” or lowest setting before servicing. 1. Note humidistat setting and turn dial to the “Off” position. 2. Remove two aluminum knobs (1), swing up and remove top cover (2) from humid[...]
-
Page 16
- 14 - MAINTENANCE INSTRUCTIONS for APRILAIRE HUMIDIFIER MODELS 445-448 WARNING! 120 volts may cause serious injury from electrical shock. Disconnect power and shut off water supply before servicing. 1. Note humidistat or Humidifier Control setting and turn dial to the “Off” position. 2. Disconnect electrical power and turn off water supply. 3.[...]
-
Page 17
- 15 - A. TO CLEAN RESERVOIR 1. Hold bottom of reservoir (IT IS FILLED WITH WATER) and loosen retainer knob. Carefully lower reservoir, disengaging from metal frame. 2. Empty water, remove partition and reservoir liner. 3. Clean or replace reservoir liner. Reinstall partition in liner. To replace reservoir, hook back of reservoir over lip of dark m[...]
-
Page 18
- 16 - MODELS 558-560-568 1. Note humidistat or Humidifier Control setting and turn dial to the “OFF” position. 2. Turn off water supply. 3. At the side of the unit opposite the airflow duct pull front cover (1) off holding with both hands and set aside. 4. Carefully pull the plastic feed tube (2) out of the nozzle (3) at the top of the Water P[...]
-
Page 19
- 17 - 1. Note humidistat or Humidifier Control setting and turn dial to the “OFF” position. 2. Disconnect electrical power and turn off water supply. 3. Unlatch humidifier cover assembly (1) from base assembly (2) at the bottom of the cover, lift, and set aside. 4. Pull out the evaporative assembly (3) by grasping at the top and tipping out. 5[...]
-
Page 20
Your Research Products Corporation Aprilaire ® Humidifier unit is expressly warranted for one (1) year from date of installation to be free from defects except, however, for the disposable Water Panel which will have to be replaced from time to time depending upon the amount of use. Research Products Corporation’s exclusive obligation under this[...]