A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Aprilaire 4655, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Aprilaire 4655 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Aprilaire 4655. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Aprilaire 4655 should contain:
- informations concerning technical data of Aprilaire 4655
- name of the manufacturer and a year of construction of the Aprilaire 4655 item
- rules of operation, control and maintenance of the Aprilaire 4655 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Aprilaire 4655 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Aprilaire 4655, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Aprilaire service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Aprilaire 4655.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Aprilaire 4655 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Manual Humidifier Control Safety and Installation Instructions WARNING A TTENTION INST ALLER: This product must be installed by a qualified heating and air conditioning contractor . Failure to do so could result in serious injury from electrical shock. READ COMPLETE INST ALLA TION INSTRUCTIONS AND TEMPLA TE BEFORE ST ARTING.[...]

  • Page 2

    2 WARNING 1. 120 volts may cause serious injury from electrical shock. Disconnect electrical power to the furnace before starting installation. 2. Sharp edges may cause serious injury from cuts. Use care when cutting plenum openings and handling ductwork. CAUTION 1. Do not set humidity higher than recommended. Condensation damage may result. 2. Do [...]

  • Page 3

    3 LOCA TION For Wall Mount: • Locate on an inside wall of living area approximately 5’ above the floor . • Do not locate control in the direct path of drafts from open doors and windows. • Do not install where operation might be affected by lamps, sunlight, fireplace, registers, radiators, concealed air ducts and pipes, or room occupants. ?[...]

  • Page 4

    4 INST ALLING AND WIRING Wall Installation: 1. Select location for the Humidifier Control on an inside wall. Mount the Humidifier Control in a location where low voltage wires from the furnace area are already in place, or can be easily run. 2. Drill a 1/2” hole into the wall at the selected Humidifier Control location. 3. Pull low voltage wires [...]

  • Page 5

    5 ANCHOR F (x2) SCREW E (x2) BASE PLA TE D HUMIDIST A T SWITCH C COVER B KNOB A BASE PLA TE D Figure 1 – Wall Mount 90-1228[...]

  • Page 6

    6 Duct (sheet metal) Installation: 1. Select Humidifier Control location on furnace return air duct. 2. Use the attached template to mark the duct opening. 3. Carefully cut the opening in the duct. 4. (See Figure 2 ) Gently pull knob (A) from Humidifier Control cover (B). Cover is held in place by snap clips. Remove cover by pulling carefully . Do [...]

  • Page 7

    7 SCREW H (x4) INSIDE OF RETURN DUCT GASKET G BASE PLATE D HUMIDISTAT SWITCH C COVER B KNOB A RETURN DUCT Figure 2 – Sheet Metal Duct Mount 90-1229[...]

  • Page 8

    8 Duct (fiber board) Installation: 1. Select Humidifier Control location on furnace return air duct. 2. Cut a rectangular hole in the duct board, no smaller than 5-3/4 inches long by 3-3/4 inches wide. 3. Cut a rectangular piece of sheet metal to fit behind the hole in duct board for mounting the Humidifier Control. 4. Use the attached template to [...]

  • Page 9

    9 KNOB A SHEET MET AL PLA TE CUT OPENING IN RETURN DUCT RETURN DUCT SHEET MET AL PLA TE RETURN DUCT BASE PLA TE D COVER B HUMIDIST A T SWITCH C GASKET G SCREW H (x4) INSIDE OF RETURN DUCT Figure 3 – Fiber Board Duct Mount 90-1230[...]

  • Page 10

    10 SPECIFICA TIONS RANGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15% to 50% OPERA TIONAL DIFFERENTIAL . . . . . . . . . . . 8% RH NOMINAL DIMENSIONS (Inches) Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1/8” Height . . . . . . . . . . . . . . . . . . . . . . . . . . . .[...]

  • Page 11

    11 INST ALLA TION TEMPLA TE TEMPLA TE SIZE: 4-5/32” x 2-7/16” 1. CUT OUT TEMPLA TE ALONG EDGES. 2. PLACE TEMPLA TE ON THE SHEET MET AL RETURN PLENUM UPSTREAM OF (BEFORE) THE HUMIDIFIER CONNECTION. 3. TRACE OUTSIDE EDGES OF TEMPLA TE. 4. REMOVE TEMPLA TE AND ACCURA TEL Y CUT OPENING. 5. USING 4 SHEET METAL SCREWS, INST ALL HUMIDIFIER CONTROL IN [...]

  • Page 12

    RESEARCH PRODUCTS CORPORA TION P .O. BOX 1467 • MADISON,WI 53701-1467 Call 800/334-6011 • FAX 608/257-4357 10007235 8.07 B2204275A Printed in USA[...]