Aprilaire 8353 manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Aprilaire 8353, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Aprilaire 8353 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Aprilaire 8353. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Aprilaire 8353 should contain:
- informations concerning technical data of Aprilaire 8353
- name of the manufacturer and a year of construction of the Aprilaire 8353 item
- rules of operation, control and maintenance of the Aprilaire 8353 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Aprilaire 8353 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Aprilaire 8353, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Aprilaire service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Aprilaire 8353.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Aprilaire 8353 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    1 Installation Guide IMPORT ANT SAFETY INFORMA TION WARNING: • Always turn off power at the main power source by unscrewing fuse or switching circuit breaker to the off position before installing, removing, cleaning, or servicing thermostat. • Read all of the information in this manual before installing or programming this thermostat. • This [...]

  • Page 2

    Features • Four setpoints for weekday programming—two setpoints for weekend comfort. • T wo “AA” ENERGIZER brand batteries retain program memory, even during power outages. • Low battery indicator . • Fahrenheit/Celsius display option. • Programmable from 45°F (4°C) to 90°F (32°C). • Accuracy within ± 1 degree. • Adjustable[...]

  • Page 3

    Figure 1 Installing the Model 8353 Thermostat NOTE: For new installations, mount thermostat on inside wall, 4-5 feet above the floor . Do not install behind a door , in a corner , near air vents, in direct sunlight, or near any heat or steam generating fixtures. Installation at these places will affect thermostat operation. 1. T urn power off to th[...]

  • Page 4

    Figure 3 7. Drill the marked holes using a 3/16” drill bit. Note: Enclosed plastic anchors do not require a drilled hole for drywall. 8. T ap plastic anchors into the wall. 9. Align base with plastic anchors and feed wires through opening. See Fig 4. Figure 4 10. Secure base to wall with supplied screws. 11. Connect wires to terminal strip. Refer[...]

  • Page 5

    13. Install two “AA” ENERGIZER brand batteries or equivalent into battery compartment. Be sure to match positive (+) ends of batteries with positive (+) battery terminals in the battery compartment. The display will show as follows: 14. Replace cover onto thermostat by snapping into place. 15. T urn on power to system . T est thermostat as desc[...]

  • Page 6

    5. Press 6. Press T o change T emperature Differential* *The T emperature Differential is Factory preset at 1°. This means that whenever the room temperature changes by one full degree from the temperature setting, the system will turn on. If the system turns on too often, increase the temperature differential. 7. Press SET to finish. Changing Fah[...]

  • Page 7

    4. Press SET . 5. Press or to change MORN temperature. 6. Repeat Steps 2-5 for DA Y , EVE, and NITE. 7. Press SET to finish. 8. Shift COOL-OFF-HEA T switch to HEA T position. 9. Repeat steps 2-7 to program HEA T (winter) settings. NOTE: Both summer and winter programs use the same time settings. Y our thermostat is now programmed for summer and win[...]

  • Page 8

    T emporary Program Override T o temporarily increase or decrease temperature Press or The thermostat will automatically return to the program at the next scheduled setting change or after four hours. Manual Operation Manual operation allows continuous override of the program settings. 1. Press PROG/MAN until indicator is in MAN position. 2. Press o[...]

  • Page 9

    T o T est Thermostat WARNING: DO NOT SHORT (JUMPER) ACROSS TERMINALS OF GAS V ALVE OR SYSTEM CONTROL TO TEST OPERA TION. THIS WILL DAM- AGE THE THERMOST A T AND VOID YOUR WARRANTY . CAUTION: Do not switch system to cool if the temperature is below 50°F (10°C). This can damage the air conditioning system and cause personal injury . 1. Place the CO[...]

  • Page 10

    T roubleshooting Symptom Remedy Thermostat does not turn Check Wiring on system (see INST ALLA TION). Check fuse. Replace with 2 amp Slo-Blo fuse if fuse has opened. Thermostat turns on and off too Increase T emperature Differential frequently . (see PROGRAMMING). Display is blank, flashing or Replace batteries. constant “LO BA T .” Weekend Pro[...]

  • Page 11

    Wiring Diagrams The following is just a sample of the most common types of HV AC sys- tems. Refer to your systems installation manual for wiring information. 11 Hot Heating Control Fan Control Cooling Control (COOLING) Transformer (HEATING) Transformer Transformer T H E R M O S T A T T H E R M O S T A T RH RC W Y G T H E R M O S T A T RH RC W Y G 2[...]

  • Page 12

    Limited W arranty Y our Resear ch Products Corporation Aprilaire ® Thermostat unit is expressly warranted for two (2) years from date of installation to be free from defects in materials and workmanship. Research Products Corporation’ s exclusive obligation under this warranty shall be to supply , without charge, a replacement for any thermostat[...]