A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of APW Wyott SHFWEZ-4D, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of APW Wyott SHFWEZ-4D one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of APW Wyott SHFWEZ-4D. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of APW Wyott SHFWEZ-4D should contain:
- informations concerning technical data of APW Wyott SHFWEZ-4D
- name of the manufacturer and a year of construction of the APW Wyott SHFWEZ-4D item
- rules of operation, control and maintenance of the APW Wyott SHFWEZ-4D item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of APW Wyott SHFWEZ-4D alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of APW Wyott SHFWEZ-4D, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the APW Wyott service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of APW Wyott SHFWEZ-4D.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the APW Wyott SHFWEZ-4D item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Phone: +1 Fax: +1 (214) 565-0976 T oll Free: +1 (800) 527-2100 Website: www .apwwyott.com E-mail: info@apwwyott.com (214) 421-7366 INST ALLA TION AND OPERA TING INSTRUCTIONS INTENDED FOR OTHER THAN HOUSEHOLD USE Models: SM50EZ, SHFWEZ-12D, SHFWEZ-1, SHFWEZ-2D, -3D, -4D, -5D, -6D RET AIN THIS MANUAL FOR FUTURE REFERENC E UNIT MUST BE KEPT CLEAR OF C[...]
-
Page 2
2 GENERAL INST ALLA TION INST ALLA TION INSTRUCTIONS FOR EZ WELL SUPPL Y LINE 1. Always clean equipment thoroughly before use. (See general cleaning instructions.) 2. Check rating label for your model designation & electrical rating. 3. For best results, use st ainless steel counter tops. 4. All dimensions in parenthesis in centimeters unless n[...]
-
Page 3
3 GENERAL OPERA TION INSTRUCTIONS GENERAL CLEANING INSTRUCTIONS GENERAL TROUBLESHOOTING 1 . All food service equipment should be operated by trained personnel. 2. Do not allow your customers to come in contact with any surface labeled "CAUTION HOT ." 3. Do not cook, warm or hold food directly in liner pans (well p ans). Always use steam t[...]
-
Page 4
4 Drain E 12.02 (305) W ater Inlet 1 10.69 (27.1) A 610 (155) B C 7.78 (198) 7.55 (192) 8.12 (20.6) 4.19 (10.6) 2 D Soup Well Cut-out 6.0 (15.2) Minimum From Counter Edge 2.0 (5.1) Minimum From Counter T op F G Control Cut-Out APW EZFILL HOT FOOD WELLS Part Numbers Beginning with WHFW INST ALLA TION OPTIONS OPERA TION CLEANING 1. W ater fill is 3/8[...]
-
Page 5
5 APW EZFILL HOT FOOD WELLS Part Numbers Beginning with WHFW INST ALLA TION OPTIONS OPERA TION CLEANING MODEL OUTSIDE DIMENSIONS CUT -OUT CONTROL CUT -OUT SHIP WT . SM50EZ-12D WELL 15.21 12.71 13.49 13.75 1 1.50 5.0 12.5 22 Lbs. (38.6) (32.3) (34.3) (34.9) (29.2) (12.7) (31.8) (10.6 Kg) AB C E D F G GENERAL SPECIFICA TIONS (APW EZFILL HOT FOOD WELL[...]
-
Page 6
APW EZFILL HOT FOOD WELLS Part Numbers Beginning with WHFW INST ALLA TION OPTIONS OPERA TION CLEANING MODEL OUTSIDE DIMENSIONS CUT -OUT CONTROL CUT -OUT SHIP WT . SHFWEZ-1 WELL 15.38” 23.44” 13.80” 12.85” 14.25” 22.25” 5.0” 12.5” 12.4 Lbs. (39.1) (59.5) (35.10) (32.6) (36.2) (56.5) (12.7) (31.8) (10.9 Kg) A B CHDE F G GENERAL SPECIF[...]
-
Page 7
7 APW EZFILL HOT FOOD WELLS Part Numbers Beginning with WHFW INST ALLA TION 1. W ater fill is 3/8 (1.0) tubing connection on left back of left controls. 2. Overflow drain is 1/2” (1.3) OD tube outlet 3. Main drain is ¾ female NPT . 1. Follow general installation instructions on page 3. 2. Make applicable Cut-Out per above table. Unit is designed[...]
-
Page 8
8 SM50EZ Round Soup Well Drop-In with EZ Lock P/N EZSM50-7D 208/240V , 500/650W P ARTS LIST & EXPLODED VIEW 31 32 33 34 35 35 36 37 38 39 40 41 42 43 44 45 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 17 18 19 20 21 22 23 23 24 24 25 26 27 28 29 30 “B” DET AIL “B” EXPLODED VIEW SM50EZ[...]
-
Page 9
Heating Element Indicator Light Robert Shaw Thermostat Heating Element Indicator Light Ranco Thermostat 9 1 54561 Control Box W/Assy 12.50 " 2 54503 Bezel Control 12.50" 3 56527 Thermostat 36" Capillary 4 56528 Knob, Black 5 63012 Indicator Light (56530) 6 54577 Adapter , 1/4" T ube T o 3/8” Pipe 7 54578 T ubing, Copper , 1/4?[...]
-
Page 10
10 DET AIL “C” DET AIL “D” “C” “D” 7 24 16 1 2 3 4 5 6 8 9 10 11 12 13 13 14 15 17 18 19 19 20 21 22 23 25 26 27 28 29 30 36 34 34 32 33 33 46 51 35 38 43 31 37 39 40 41 42 44 45 50 50 49 48 48 47 47 Small Frame Insulated T op Mount EZ Fill Hot Food Wells HFWEZ12D, P/N EZ12D4B-208/240V -500/660W P ARTS LIST & EXPLODED VIEW EXPLO[...]
-
Page 11
11 31 88961 32 89025 33 89059 34 89061 35 55343 36 89120 37 5451 1 38 54524 39 54513 40 54510 XXXX 41 54512 42 54503 43 56527 44 56536 45 54577 46 56945 47 56412 48 5641 1 49 55305 50 56402 51 56388 56542 Plate, Dial-Wells 54532 Wire Set T wo Well 54533 Wire Set Three Well 54534 Wire Set Four Well 54535 Wire Set Five Well 54536 Wire Set Six Well 10[...]
-
Page 12
DET AIL “B” “B” 12 Small Frame Insulated T op Mount EZ Fill Hot Food Wells HFWEZ-1D SHFWEZ-1D P/N EZ1D2B-208V -1600W , SHFWEZ-1D P/N EZ1D4B-208/240V -1200/1600W P ARTS LIST & EXPLODED VIEW EXPLODED VIEW HFWEZ-1D 7 7 24 24 16 1 2 3 3 4 5 6 6 8 8 9 9 10 11 12 13 14 15 17 18 19 19 19 19 20 20 21 21 21 21 21 22 23 23 25 26 27 28 29 30 36 34[...]
-
Page 13
13 35 88971 Screw 8-32 X 1-1/2 SS 36 54548 Spacer , Probe Holder 37 56655 Drain Strainer 38 54561 Control Box W/assy 12.50” 39 5451 1 Octal Base Use With 54510 40 54524 Bracket, Solenoid V alve 41 54513 Water Solenoid V alve 42 54510 Liquid Level Control Octal Base XXXX Liquid Level Control Open Board 43 54512 Hold Down Strap Use With 54510 44 54[...]
-
Page 14
Note: When ordering, AL W A YS specify Part #, Model #, Serial #, V oltage & Phase. P/N 70103067 7/05 11 48 12 56 51 54 44 53 52 24 6 32 30 4 9 60 7 34 18 16 17 19 21 20 41 1 42 40 26 60 50 48 45 44 24 11 39 30 32 2 9 12 13 14 15 31 35 36 37 33 59 58 57 56 55 54 53 52 51 49 47 46 43 25 27 29 38 4 22 28 3 5 6 8 10 23 7 EXPLODED VIEW SHFWEZ-1D w/[...]
-
Page 15
Item Item Description Description P/N Quan Quan P/N 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 54577 56542 56388 89073 89059 56513 52107 56360 89390 70101018 30201 54508 54510 5451 1 54513 54543 54544 54545 54546 54548 54549 55308 55340 55343 55441 56039 56506 56515 56516 56541 Adapter , 1/4" T o 3/8"[...]
-
Page 16
Small Frame Insulated T op Mount EZ Fill Hot Food Wells HFWEZ-2, -3, -4, -5, -6 P ARTS LIST & EXPLODED VIEW EXPLODED VIEW HFWEZ-2, -3, -4, -5, -6 53 52 51 7 24 24 24 16 1 2 3 4 5 6 8 9 10 11 12 13 14 15 17 18 19 20 21 22 23 23 23 23 23 25 25 26 27 28 29 30 36 34 32 33 46 35 38 43 31 37 39 40 41 42 44 45 50 49 48 47 HFWEZ-2D EZ2D2B 208 1600 HFWE[...]
-
Page 17
31 54524 Bracket, Solenoid V alve 32 54508 Brass Fitting 1/8 NPT X ¼ Compression 33 54504 Control Box W/assy 12.50" 54522 Control Box W/assy 16.50” 54529 Control Box W/assy 33.50” 34 54512 Hold Down Strap Use With 54510 35 54510 Liquid Level Control Octal Base XXXX Liquid Level Control Open Board 36 88977 6-32 X 1.0 Slotted Pan Head 37 54[...]
-
Page 18
EXPLODED VIEW SHFWEZ-2D, 3D, 4D, 5D, 6D w/SHUT -OFF V AL VE 18 35 38 41 29 26 40 28 42 36 16 34 1 5 30 43 6 1 1 3 4 20 17 2 48 24 44 14 37 1 0 23 19 1 2 9 27 50 31 49 50 53 NA 51 58 52 54 59 23 21 22 24 25 26 27 28 30 29 31 32 52 53 51 42 50 50 48 47 49 44 33 46 45 43 41 40 34 35 36 37 38 39 20 18 17 15 14 13 19 16 12 11 8 10 10 5 6 7 9 4 3 2 1 NA [...]
-
Page 19
Note: When ordering, AL W A YS specify Part #, Model #, Serial #, V oltage & Phase. P/N 70103068 7/05 W/Ass'y , EZ Fill Well, 600 Pan W/Ass'y , Drain Strainer Sealant, Gs7500, 6.5 Ft. Lg. Plate, Hole Cover W/Ass'y , 600 Well Pan Conduit 3/4" Length 24" Clip, Jiffy Plate, Reflector Nut, Hex 10-24 Screw 10-32x3/8 T rs Hd [...]
-
Page 20
HFW-2 L1 L2 L1 L2 HFW-3 L1 L2 HFW-4 L1 L2 HFW-5 HFW -6 L1 L2 HFWEZ-2, -3, -4, -5. 6 WIRING DIAGRAM (THERMOST A TIC CONTROL CONFIGURA TION) Heating Elements Thermostat Indicator Lights 1 14 15 16 17 21 22 23 24 25 26 27 28 29 30 31 2 3 4 5 6 7 8 9 10 11 12 13 18 19 19 19 19 19 20 L1 L2 Heating Elements Wire Nuts Thermostat Indicator Lights 1 2 3 4 5[...]
-
Page 21
21 IMPORT ANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment. For W arranty Service and/or Parts, this information is required. Model Number Serial Number Date Purchased Notes:[...]
-
Page 22
Notes: 22[...]
-
Page 23
23[...]
-
Page 24
APW WYOTT 729 Third Avenue Dallas, TX 75226 Phone: +1 Fax: +1 (214) 565-0976 T oll Free: +1 (800) 527-2100 Website: www .apwwyott.com E-mail: info@apwwyott.com (214) 421-7366 24 R[...]