Go to page of
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of AquaPRO GPH550PRO, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of AquaPRO GPH550PRO one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of AquaPRO GPH550PRO. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of AquaPRO GPH550PRO should contain:
- informations concerning technical data of AquaPRO GPH550PRO
- name of the manufacturer and a year of construction of the AquaPRO GPH550PRO item
- rules of operation, control and maintenance of the AquaPRO GPH550PRO item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of AquaPRO GPH550PRO alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of AquaPRO GPH550PRO, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the AquaPRO service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of AquaPRO GPH550PRO.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the AquaPRO GPH550PRO item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. Operating In[...]
-
Page 2
Operating Instructions and Replacement Parts List 2 An air leak in the suction line may prevent priming of the pump. Use of thread sealant is recommended. Suction lines must be reinforced hose or rigid pipe. Non-reinforced hose will collapse due to the suction created by the pump and prevent pump from operating. 3. A check valve must be used in the[...]
-
Page 3
3 Operating Instructions and Replacement Parts List FEET FRICTION LOSS IN 100 FEET OF PLASTIC PIPE Gallons Per Minute Pipe Size 20 25 30 40 50 60 80 100 120 1 1 / 4 5.6 8.5 11.9 20.2 30.5 1 1 / 2 2.6 4.0 5.5 9.4 14.3 19.9 34.2 2 1.2 1.6 2.8 4.2 5.8 9.9 15.0 21.2 2 1 / 2 1.2 1.8 2.5 4.2 6.3 8.8 Performance Information Semi-T rash Pump Performance 0 [...]
-
Page 4
4 LAY FLAT DISCHARGE HOSE PART #16511 • Economical • Lightweight • Resistant to oils, light chemicals, abrasion and sunlight • Will not rot, mildew or absorb water Hose couples one end with 2" hose thread. One 25 ft. hose per carton SUCTION HOSE PART #16510-002 • Reinforced to prevent collapse under suction Hose coupled both ends wit[...]
-
Page 5
For Replacement Parts, call 1-877-278-2797 5 Item Part No. Description GPH550PRO Qty 1 Honda Engine 57812-001 1 2 Shaft Seal Kit 66047-WYN1 1 3 Suction Flange 42007-001 1 4 Flapper Check Valve 37306-001 1 5 Discharge Flange Kit 66049-WYN1 1 6 Drain/Fill Plug 28444-001 2 7 Impeller 41020-001 1 Please provide following information: - Model number - S[...]
-
Page 6
6 Operating Instructions and Replacement Parts List Limited W arranty For one year from date of purchase, Aqua Pro (”Wayne Water Systems“) will repair or replace, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (”Product“) found upon examination by Aqua Pro to be defective in materials or workman[...]
-
Page 7
Bomba Hidráulica con Motor a Gasolina Sírvase leer y guardar estas instrucciones. Lea atentamente antes de intentar ensamblar, instalar, hacer funcionar o dar servicio al producto descrito. Protéjase y proteja a los demás cumpliendo con toda la información de seguridad. El no seguir las instrucciones podría dar como resultado lesiones persona[...]
-
Page 8
Una pérdida de aire en la línea de succión puede impedir el cebado de la bomba. Se recomienda el uso de un sellador de rosca. Las líneas de succión deben ser de manguera reforzada o de tubería rígida. La manguera no reforzada se aplasta debido a la succión creada por la bomba e impide el funcionamiento de la misma. 3. Es necesario usar una [...]
-
Page 9
3 SP PÉRDIDA DE ALTURA POR FRICCIÓN EN 100 PIES (30 m) DE TUBERÍA DE PLÁSTICO Diá. de la Galones por Minuto Tubería 20 25 30 40 50 60 80 100 120 1 1 / 4 5.6 8.5 11.9 20.2 30.5 1 1 / 2 2.6 4.0 5.5 9.4 14.3 19.9 34.2 2 1.2 1.6 2.8 4.2 5.8 9.9 15.0 21.2 2 1 / 2 1.2 1.8 2.5 4.2 6.3 8.8 Características de Rendimiento Rendimiento de Bomba Semi-Res[...]
-
Page 10
4 SP MANGUERA EN LONA PARA DESCARGA REPUESTO #16511 • Económica • Liviana • Resistente al aceite, químicos no muy agresivos, abrasión y luz solar • No le da mojo ni hongos, ni absorbe agua. Manguera con un extremo con empalme enroscados de 2". Una manguera de 25 pies (7,5 m) por caja MANGUERA DE SUCCIÓN REPUESTO #16510-002 • Refo[...]
-
Page 11
Por r epuestos, llame al 1-877-278-2797 5 SP Instrucciones de Funcionamiento y Lista de Piezas de Repuesto Artículo Ref. Descripción GPH550PRO Cant. 1 Motor Honda 57812-001 1 2 Juego del sello del eje 66047-WYN1 1 3 Reborde de Succión 42007-001 1 4 Válvula de contención de charnela 37306-001 1 5 Juego de Reborde de Descarga 66049-WYN1 1 6 Tap?[...]
-
Page 12
6 SP Instrucciones de Funcionamiento y Lista de Piezas de Repuesto Garantía Limitada Durante un (1) año a partir de la fecha de compra, Aqua Pro (“Wayne Water Systems”) reparará o reemplazará, según lo decida, para el comprador original, cualquier pieza o piezas de sus Bombas para cloacas o Bombas de agua (el “Producto”) que después d[...]