Go to page of
Similar user manuals
-
Water System
Argosy Research H-125 Series
40 pages 2.6 mb -
Water System
Argosy Research WaterMate 3
2 pages 0.58 mb -
Water System
Argosy Research H200 Series
13 pages 2.3 mb -
Water System
Argosy Research Series H-100
2 pages 0.49 mb -
Water System
Argosy Research H200HF Series
13 pages 2.3 mb -
Water System
Argosy Research NF 1.5" Series
2 pages 0.13 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Argosy Research H200 Series, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Argosy Research H200 Series one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Argosy Research H200 Series. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Argosy Research H200 Series should contain:
- informations concerning technical data of Argosy Research H200 Series
- name of the manufacturer and a year of construction of the Argosy Research H200 Series item
- rules of operation, control and maintenance of the Argosy Research H200 Series item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Argosy Research H200 Series alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Argosy Research H200 Series, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Argosy Research service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Argosy Research H200 Series.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Argosy Research H200 Series item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
H200 & H200HF SERIES W A TER CONDITIONERS Apartment Buildings Boiler W ater T reatment Car W ashes Commercial Buildings Condominiums Factories Hospitals Laundries Mobile Home Parks Motels and Hotels Nursing and Rest Homes Ofce Buildings Restaurants Schools For Commer cial & Industrial Applications H200 T op Mount H200 Side Mount H200HF S[...]
-
Page 2
Hellenbrand Means Quality and Reliability Since 1967, Hellenbrand, Inc. has provided water solutions to the water tr eatment industry in the U.S. and around the world. Our gr owth in the water tr eatment industry is a direct r esult of pro- viding high quality products and supporting the applications for those pr oducts with over 200+ years of indu[...]
-
Page 3
• Solid state micropr ocessor can control fr om one to four units allowing you system add on capabilities as your needs grow . • Regeneration may be initiated with a time clock, meter delayed or meter immediate. • Up to nine fully programmable cycle times, that can be moved around and r epeated in various orders for your particular applicatio[...]
-
Page 4
H200/H200HF Diagnostic and Histor y Screens provide the water treatment operator with a wealth of information. Diagnostic Screens • Days since last regeneration • T otal volume treated since last regeneration • Reserve history for the current day and previous six-days • Usage history by the hour for each of the last 63 days • Maximum o[...]
-
Page 5
H200/H200HF Diagnostic and Histor y Screens provide the water treatment operator with a wealth of information. DIAGNOSTIC 5 DIAGNOSTIC 6 DIAGNOSTIC 7 DIAGNOSTIC 7-B WS2H Control V alve Manual Page 21 Diagnostic Screens (continued) DIAGNOSTICS 5 Maximum fl ow rate for the last 28 days. Max fl ow rate of the day DIAGNOSTICS 5-B Hourly history of ma[...]
-
Page 6
H200/H200HF Diagnostic and Histor y Screens provide the water treatment operator with a wealth of information. HISTOR Y 1 HISTOR Y 2 HISTOR Y 3 Page 22 WS2H Control V alve Manual V alve History Returns to normal operation after 5 minutes. Accessed by pressing UP and DOWN simultaneously for >3 seconds, then by pressing UP and DOWN simultaneously [...]
-
Page 7
Modes of Regeneration Time Clock - 7 or 28 day calendar clock shall initiate regeneration at a pr e-set time of day . Parallel Individual Meters - All units are in service at the same time with either delayed or immediate r e- generation. A lockout feature or of fsetting time of regeneration pr events more than one unit to r egenerate at a time. Un[...]
-
Page 8
A . MINERAL T ANK: Fiberglass tank with Polyethylene Inner Shell and Fiberglass Roving Manufactured to Operate at 150 psi. NSF Approved. B. DISTRIBUTOR SYSTEM: T wo-Inch Hub & Lateral Dis - tributor for Maximum Service Flow and Minimal Pressure Loss. C. MINERAL: High Capacity Ion Exchange Resin. Uniform and stable beads assure long life, high s[...]
-
Page 9
Brine T ank(s) Inlet Bypass V alve Brine T ank(s) Outlet Isolation V alves Flex Connectors MA V V alve H200 T win/T riple x/Fourple x Installation T op-Mount - First-in, Last-Out Piping Arrangement. H200 Single Installation - Side Mount Brine T ank Inlet Outlet Bypass V alve Isolation V alves Sidemount Adapter Base Brine Line 1" MNPT 2” FNPT[...]
-
Page 10
H200 T win Alternating - Side Mount H200 T win/T riple x/Fourple x Installation - Side Mount First-in, Last-Out Piping Arrangement. Brine T ank See NOTE Figure 7 Figure 6 Brine T ank(s) Figure 7 NOTE: System connections to the tank must accommodate longitudinal movement between side, top and bot- tom openings, exibility in piping or ex connec[...]
-
Page 11
H200 HF Single T ank Installation H200 HF T win Alternating Installation H200 HF T riple x/Fourple x Installation Brine T ank See NOTE Figure 7 Figure 8 See NOTE Figure 7 Figure 9 See NOTE Figure 7 Figure 10 Outlet Meter High Flow Service V alve 1 Bypass V alve Inlet Outlet is Plugged High Flow Service V alve Pipe is on an angle Isolation V alve 1 [...]
-
Page 12
RECOMMENDED BRINE T ANK APPROXIMA TE PIPE SIZE MINERAL T ANK SIZE SAL T STORAGE SHIPPING WEIGHT -TOP MOUNT MODEL (INCHES) (INCHES) (INCHES) ( LBS) SINGLE TWIN H200-240 2 24 X 72 24 X 50 715 674 1325 H200-300-24 2 24 X 72 24 X 50 715 776 1529 H200-300-30 2 30 X 72 30 X 50 1,1 10 1059 2064 H200-450-30 2 30 X 72 39 X 48 2,030 1333 2593 H200-450-36 2 3[...]
-
Page 13
RA TED CAP ACITY FLOW RA TES (gpm) RESIN LOW SAL T MEDIUM SAL T HIGH SAL T BKW MODEL CU.FT . GRAINS/LBS GRAINS/LBS GRAINS/LBS 15 PSI 25 PSI GPM H200HF-300-24-3 10 190,000/60 280,000/100 320,000/150 120 170 12 H200HF-300-30-3 10 190,000/60 280,000/100 320,000/150 175 225 20 H200HF-450-30-3 15 285,000/90 420,000/150 480,000/225 158 212 20 H200HF-450-[...]