Ariston GL 2.5 Ti manual

1
2
3
4
5
6
7
8
9
10
11
12
13

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Ariston GL 2.5 Ti, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Ariston GL 2.5 Ti one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Ariston GL 2.5 Ti. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Ariston GL 2.5 Ti should contain:
- informations concerning technical data of Ariston GL 2.5 Ti
- name of the manufacturer and a year of construction of the Ariston GL 2.5 Ti item
- rules of operation, control and maintenance of the Ariston GL 2.5 Ti item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Ariston GL 2.5 Ti alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Ariston GL 2.5 Ti, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Ariston service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Ariston GL 2.5 Ti.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Ariston GL 2.5 Ti item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    MTS MAKES USE OF RECYCLED P APER 029.1.60.435.2.00 0604 Litograf s .r .l. Jesi Controlled Energy Cor p . 340 Mad River P ar k W aitsfield, VT 05673 800-798-8161 www .protankless.com/tech INST ALLA TION MANU AL FOR DIRECTIVES D’INST ALLA TION POUR INSTR UCCIONES DE SEGURID AD IMPORT ANTES mini-tank electric water heaters chauff e-eau électr iques[...]

  • Page 2

    The installer should revie w the contents of this manual with the owner upon completion of installation, and the manual should be left with the owner and placed in a location close to the installation. IMPOR T ANT SAFETY INSTR UCTIONS When using electrical appliances, safety precautions to reduce the risk of fire, electric shock or injury to person[...]

  • Page 3

    T emperature & pressure relief valve, 3/4 NPT male T emperature & pressure relief valve, 3/4 NPT male 3/4 NPT female tapping for relief valve 3/4 NPT female tapping 3/4 NPT female tapping 3/4 NPT female tapping for relief valve Hot water outlet 1/2 NPT male 3/4 NPT female tapping for relief valve FIG. 1/1 T emperature & pressure relief [...]

  • Page 4

    FIG. 2/1 DIMENSIONS FOR GL 2.5Ti - GL 4Ti DIMENSIONS FOR GL 8Ti (HORIZONT AL INST ALLA TION) DIMENSIONS FOR GL 8 Ti (VERTICAL INST ALLA TION) FIG. 2/2 FIG. 2/3 3 GL 2.5 GL 4 14” 10 1/4” 12 1/4” 7 1/2” 3” 6” 3 1/2” 1” 14” 5 1/2” 3 3/4” 2 1/2” 14 1/2” 8 1/2” 4 1/2” 17 1/2” 14 1/2” 8 1/2” 4 1/2” 11 1/2” 17 1/2?[...]

  • Page 5

    General remarks The manuf acturer cannot be responsible f or the damages caused by improper installation or by f ailure to follow instructions in this pamphlet. Comply with the installation instructions before completing electric connection. The thermostat has been pre-set at the factory at or below 51.7 °C (125° F). Hydrogen gas can be produced [...]

  • Page 6

    MODEL GL 2.5Ti - GL 4Ti The GL 2.5Ti and GL 4Ti water heaters can be installed under the sink. F asten the supplied mounting bracket to the w all. Use screws that are suitab le for the wall material and the weight of the heater . Hang the water heater on the brack et. T ug down wards on the heater to ensure that both “fingers” of the brack et a[...]

  • Page 7

    Heater can sit on floor . Connect the cold water inlet pipe to the inlet nipple (marked with a b lue ring) and the hot water outlet pipe to the outlet nipple (marked with a red ring). T o reduce the risk of excessiv e pressures and temperatures in this w ater heater , install the supplied temperature and pressure protectiv e equipment required by l[...]

  • Page 8

    Maintenance instructions Note: Do not attempt to repair this water heater your self. Call a ser vice person for assistance. Alwa ys turn off the power suppl y to the heater prior to servicing or draining the heater . P eriodic maintenance Note: For most of these operations, the water will have to be drained from the heater . For all of these operat[...]

  • Page 9

    Changing the anode rod REPLA CEMENT OF P ARTS B) Once the element has dried up, use a soft brush (non metallic to pre v ent damaging the stainless steel sheath) on element. Brush the dried mineral off. Reinstall the element with gasket and mak e the wire connections. C) Replace anode rod ( N Fig. 5/2) if it is noticeably deteriorated or considerabl[...]

  • Page 10

    9 W ater does not get hot Light not on Bro wn water Odor in water W ater is too hot W ater not hot enough Leaking T roub leshooting 1. Make sure the pow er supply is on and working. 2. If light does not come on, check that the reset button is pushed in; follow steps from previous section. 3. If the indicator light works proper ly but temper ature d[...]

  • Page 11

    10 DESCRIPTION REF . P ART CODE DESCRIPTION REF . 1 100XL V AL VE (T&P 3/4”) ABC 2 570241 ANODE (MA GNESIUM) C 2 574305 ANODE (MA GNESIUM) AB 3 994147 GASKET WITH 4 BOL TS ABC 4 994140 LOCK NUT M6 ABC 5 994103 HEA TING ELEMENT (1500/120) AB 5 994104 HEA TING ELEMENT (1500/120) C 6 PLASTIC CO VER RET AINING SCREW 7 NAME BADGE (PLASTIC) 8 CO VE[...]

  • Page 12

    ARIST ON GL Ti • LIMITED 8 YEARS W ARRANTY CO VERAGE ARIST ON, THROUGH ITS U.S . DISTRIBUTOR CONTROLLED ENERGY CORP ., (hereinafter CEC) guarantees this water heater to the Owner (hereinafter “Owner”) of the w ater heater at the original installation location against defects in material and workmanship f or the periods specified below . W ARR[...]

  • Page 13

    MTS MAKES USE OF RECYCLED P APER 029.1.60.435.2.00 0604 Litograf s .r .l. Jesi Controlled Energy Cor p . 340 Mad River P ar k W aitsfield, VT 05673 800-798-8161 www .protankless.com/tech INST ALLA TION MANU AL FOR DIRECTIVES D’INST ALLA TION POUR INSTR UCCIONES DE SEGURID AD IMPORT ANTES mini-tank electric water heaters chauff e-eau électr iques[...]