A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Audiovox APS-687a, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Audiovox APS-687a one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Audiovox APS-687a. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Audiovox APS-687a should contain:
- informations concerning technical data of Audiovox APS-687a
- name of the manufacturer and a year of construction of the Audiovox APS-687a item
- rules of operation, control and maintenance of the Audiovox APS-687a item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Audiovox APS-687a alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Audiovox APS-687a, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Audiovox service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Audiovox APS-687a.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Audiovox APS-687a item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
128-8121 1 of 24 1 The selectable features can be set manually as explained below , or with the RF feature programmer . T o set features using the RF programmer , follow the instructions packaged with the programmer . Factory default settings are indicated by bold text. Note : The method of manual override can either be selected to operate from the[...]
-
Page 2
128-8121 2 of 24 2 T o program these selectable features; Action System Response Turn ignition on No response Press and release the valet switch 3 times 1 Chirp - LED 1 flash Within 3 seconds, turn ignition Off Then On Short chirp, then long chirp This Action Accesses Feature Bank 2 Alarm Selectable Features First Press and release the valet switch[...]
-
Page 3
128-8121 3 of 24 3 T o exit program mode, turn ignition off, or press and release valet switch. RF Programmable Features Bank 3 Is Remote Start Selectable Features: Feature Selection 1 Chirp 2 Chirps 3 Chirps 4 Chirps 5 Chirps 6 Chirps 1st Defrost Output Pulsed 10 Mins 2nd RF S tart Chirp O f f On On & Car Finder 3rd Run Time 5 Mins 10 Mins 15 [...]
-
Page 4
128-8121 4 of 24 4 Action System Response Turn ignition on No response Press and release the valet switch 3 times 1 Chirp - LED 1 flash Within 3 seconds, turn ignition Off, On, Off, On Short chirp, then 2 long chirps This Action Accesses Feature Bank 3 Remote S tart Selectable Features First Press the valet switch one time 1 chirp = defrost output [...]
-
Page 5
128-8121 5 of 24 5 This system is to be used in vehicles with AUTOMA TIC TRANSMISSIONS only! Although this combina- tion Keyless Entry/Remote S tart unit is a sophisticated system with many advanced features, IT MUST NOT be installed into a vehicle with a manually operated transmission. Doing so may result in serious personal injury and property da[...]
-
Page 6
128-8121 6 of 24 6 This Remote S tart System is designed for use with Automatic T ransmission V ehicles Only! The unit provides wait to start input for glow plug pre-heat which will be used for all diesel applications. If this wire is not connected, then the unit will remain in the Gasoline mode setting, which will crank the car when the RF signal [...]
-
Page 7
128-8121 7 of 24 7 Note: This wire must be connected to the vehicle side of the starter cut relay (when used). For the electrical neutral switch configuration, this connection must be made between the starter inhibit relay , (when used) and the neutral safety switch as shown in the following diagram. Failure to connect this wire to the ignition swi[...]
-
Page 8
128-8121 8 of 24 8 WIRING THE 4 PIN AL TERNA TE IGNITION HARNESS ORANGE/BLACK Wire: Parking Brake Input This wire is used only when the turbo timer mode, Bank 3, feature # 16 is selected ON. This input insures that the vehicle parking brake is applied whenever the vehicle is set up for and the turbo timer circuit is used. This input must switch to [...]
-
Page 9
128-8121 9 of 24 9 WIRING CONNECTIONS: 12 Pin Input / Output Harness Black Wire: Chassis Ground Source Connect the Black wire to a known vehicle ground source or to a solid clean metal part of the chassis. Be certain to remove any paint or grease and secure this wire with a self- tapping screw and ring terminal. GRAY WIRE: Negative Inhibit Input 1 [...]
-
Page 10
128-8121 10 of 24 10 YELLOW w/ BLACK Tracer Wire: + 12 Volt Alarm By - Pass Output Note: You must disconnect the ignition input of the alarm from any other wire that it is presently connected to in the vehicle. This wire provides a + 12 Volt output when the ignition key is turned to the “ON” position, and 0 Volts when the ignition key is “OFF[...]
-
Page 11
128-8121 11 of 24 11 C. GM V A TS Key Override: If the vehicle has the General Motors V A TS system installed, you will need to bypass the system while the vehicle is operating under the control of the Remote S tart Unit. T o Do This; 1. Measure the resistance of the resistor pellet on the ignition key then select a resistor within 5% of the key&ap[...]
-
Page 12
128-8121 12 of 24 12 Green/Y ellow Wire: Diesel W ait T o S tart Input The Green/Yellow wire will connect to a diesel vehicles glow plug wire. When the unit receives a start command, this wire must go to + 12 then to ground to allow the crank sequence to begin. When ignition #1 is activated by the remote start unit, the glow plug circuit gets energ[...]
-
Page 13
128-8121 13 of 24 13 3 Pin Door Lock/Unlock Harness: (White Connector) The Red and Green wires will provide either a pulsed ground output to the factory door lock control relay , or a pulsed + 12 volt output to the factory door lock control relay . In either case, the maximum current draw through these outputs must not exceed 300mA. The Red w/Black[...]
-
Page 14
128-8121 14 of 24 14 Most vehicles door lock/unlock motor legs rest at ground, and switch +12 volts to the door lock/unlock motor legs for operation, if this is the case in the vehicle you are working on, connect the remaining terminal, 87, to a fused + 12 volt source. In the rare instance that the vehicle door lock/unlock motor legs rest at + 12 v[...]
-
Page 15
128-8121 15 of 24 15 5 Pin Accessory Output Harness Dark Blue Wire : Delayed 300 mA Pulsed Output/Channel 3 The dark blue wire pulses to ground via an independent RF channel from the keychain transmitter. This is a transistorized, low current output, and should only be used to drive an external relay coil. This output is activated by the same trans[...]
-
Page 16
128-8121 16 of 24 16 wire the remaining relay contacts to perform the selected function of channel 6. Blue/Red Wire : DELA YED 300 mA PULSED OUTPUT / CHANNEL 7 The light blue/red wire pulses to ground via an independent RF channel from the keychain transmitter . This is a transistorized, low current output, and should only be used to drive an exter[...]
-
Page 17
128-8121 17 of 24 17 TIMED START OPERATION: To begin the start timer, within 10 seconds of turning off the ignition switch, activate the RF command to start 2 times. (Press the trunk/key button four times). The lights will flash and the siren will chirp 4 times. Indicating timed interval mode has been initiated. The vehicle will automatically start[...]
-
Page 18
128-8121 18 of 24 18 TESTING YOUR INST ALLA TION: W ARNING!! The following procedure must be performed after the installation of an Audiovox Remote S t art Device. It is the responsibility of the installing technician to complete these tests. Failure to test the unit in the following manner may result in personal injury , property damage, or both. [...]
-
Page 19
128-8121 19 of 24 19 8. Repeat the above test this time move the gear selector to the drive position. If the unit attempts to start, failing this test, recheck your Y ellow Wire's connection. This wire must be connected to the ignition switch side of the Neutral S tart Switch. If the vehicle you are working on does not have an Electrical Neutr[...]
-
Page 20
128-8121 20 of 24 20 Note: When completing an installation using either of the following key in sensor circuits, if the operator inserts the ignition key while the vehicle is running under the control of the Remote S tart, the vehicle will shut down. This must be explained to the operator as it is in contrast to the normal operation of a vehicle ut[...]
-
Page 21
128-8121 21 of 24 21 C. Locate the key in sensor switch wire that connects the chime module to the ignition cylinder . D. Cut this wire and connect the ignition cylinder side to the Remote S tart Negative Safety Shut down Wire Gray/Black, using a 4002 series diode as shown above. Note: A second 4002 series diode may be required to maintain the inte[...]
-
Page 22
128-8121 22 of 24 22[...]
-
Page 23
128-8121 23 of 24 23 THIS PAGE LEFT BLANK INTENTIONALLY[...]
-
Page 24
128-8121 24 of 24 24 © 2007 Audiovox Electronics Corp., Hauppauge, NY 1 1788 128-8121[...]