Avocent Advanced Console Server ACS 6000 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Avocent Advanced Console Server ACS 6000, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Avocent Advanced Console Server ACS 6000 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Avocent Advanced Console Server ACS 6000. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Avocent Advanced Console Server ACS 6000 should contain:
- informations concerning technical data of Avocent Advanced Console Server ACS 6000
- name of the manufacturer and a year of construction of the Avocent Advanced Console Server ACS 6000 item
- rules of operation, control and maintenance of the Avocent Advanced Console Server ACS 6000 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Avocent Advanced Console Server ACS 6000 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Avocent Advanced Console Server ACS 6000, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Avocent service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Avocent Advanced Console Server ACS 6000.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Avocent Advanced Console Server ACS 6000 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    For T echnical Support : www.avocent.com/support 590- 7 70-50 1B C yclades ® ACS 6000 Command Reference Guide[...]

  • Page 2

    FCC Warning Statement The Cyclades ACS advanced console server has been tested and found to comply with the limits for Class A digital devices, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment gener[...]

  • Page 3

    Cyclades ® ACS 6000 Advanced Console Server Command Reference Guide Avocent, the Avocent lo go, The Power of Being There, DSView and Cyclades are register ed trademarks of Av ocent Corp oration or its affiliates in the US and other countrie s. All other marks are the property of their respective owners. © 2008 A vocent Corporation. 590-770 -501B[...]

  • Page 4

    Instructions This symbol is i ntended to alert th e user to the pres ence of important operating and maintenance (servicing) instructions in the lite rature accompanying the appliance. Dangerous V oltage This symbol is int ended to alert the use r to the prese n ce of unin sulated dangerous voltage within the product’ s enclosure tha t ma y be of[...]

  • Page 5

    iii Table of Contents List of Tables ........... .......................... .......................... ....................... .......................... . .v i i Chapter 1: Introduction, Navigation and Commands ........... ................ ............. ........... 1 Access Options and How to Log Into the CLI ............. ................. ......[...]

  • Page 6

    iv Cyclades ACS 6000 Advanced Console Server Command Reference Guide killuser .......... .................... ................. ................. ................. ................... ................. .. ............ ... 14 sendmsg......... .................... ................. ................. ................. ................... .............[...]

  • Page 7

    Table of Contents v Overview Options ................. .................... ................. ................. ................... ................. .... ............. 49 Information Options .............. ... ................. ... ................ ................. ... ................. ... ............... .. ........... 50 Active Sessions Inform[...]

  • Page 8

    vi Cyclades ACS 6000 Advanced Console Server Command Reference Guide[...]

  • Page 9

    vii List of Tables Table 1.1: ACS 6000 Advanced Console Server Port Desc riptions .............. .................... ................ 2 Table 2.1: Port Access an d Configuration Tasks ...... .................................................. ............ ........ 19 Table 2.2: Topology Parameters ........ ... ... ................. .. .............[...]

  • Page 10

    viii Cyclades ACS 6000 Advan ced Console Server Co mmand Reference Guide[...]

  • Page 11

    1 CHAPTER 1 Introduction, Navigation and Commands The Cyclades ACS 6000 advanced cons ole server is a 1U appliance that serves as a single point for access and administration of connected devices, such as target de vice consoles, modems and power devices. ACS 6000 consol e servers support secure remote data center managem ent and out-of-band manage[...]

  • Page 12

    2 Cyclades ACS 6000 Advanced Console Server Command Reference Guide Figure 1.1: ACS 6000 Advanced Console Server Port s T able 1.1: ACS 6000 Advan ced Console Server Port Descriptions Number Description 1S e r i a l P o r t 1 NOTE: Serial port s are also referred to with tty device names, such as ttSy1, ttyS2 and so forth. 2 Eth1 (eth1) 3 Eth0 (eth[...]

  • Page 13

    Chapter 1: Introduction, Naviga tion and Commands 3 Access Options and How to Log Into the CLI The CLI utility can be accesse d in the following ways: • Through a local terminal or a computer that has a terminal em ulation program connected to the console port of the console server with session settings of 96 00, 8, N and 1, with no flow control.[...]

  • Page 14

    4 Cyclades ACS 6000 Advanced Console Server Command Reference Guide For example, in the Web Manager, user configurati on is done wh en an admi nistrator selects Appliance Settings - Users - Local Accounts - User Names to get to the User Names screen. To navigate to the equivalent configurat ion level in the CLI, an administrator would navigate in t[...]

  • Page 15

    Chapter 1: Introduction, Naviga tion and Commands 5 A prompt like the following appears at each leve l: --:- appliance_settings cli- > NOTE: CLI commands are case sen sitive. At any level, you can press Tab Tab at the prompt to see the comman ds that can be entered at the current level. ---:- appliance_settings cli ->< Tab >< Tab >[...]

  • Page 16

    6 Cyclades ACS 6000 Advanced Console Server Command Reference Guide Parameters Some CLI commands take parameters. If you press Ta b Tab after a command that requires a parameter, you are prompted to enter the parameter. Command Line Synt ax NOTE: Square brackets ([ ]) denote an optional e lement. Each element is separated by a sp ace. There are no [...]

  • Page 17

    Chapter 1: Introduction, Naviga tion and Commands 7 | : or () : group CLI Command Set NOTE: Most of the commands w ork from any location when the path to the command parameter is included. NOTE: The word “node” refers to an entity su ch as a r oute, host or user , which can be add ed, configured or deleted. help Generate a help message about ho[...]

  • Page 18

    8 Cyclades ACS 6000 Advanced Console Server Command Reference Guide Syntax: --:- units cli-> add <Path> Example: --:- units cli-> add applian ce_settings/network/hosts --:#- [hosts] cli-> delete Delete a node. Syntax: --:- units cli-> delete <Pat h> <parameter> cd Change directory (level). Syntax: --:- units cli-> c[...]

  • Page 19

    Chapter 1: Introduction, Naviga tion and Commands 9 --:- overview cli-> pwd Display the path to the current level (print work ing director y). Syntax: --:- units cli-> pwd connect Connect to a serial or auxiliary port. Syntax: --:- topology cli-> connect < port_name > Example: --:- topology cli-> connect 77-77-70 -p-2 -or- (Option[...]

  • Page 20

    10 Cyclades ACS 6000 Advanced Console Server Command Reference Guide Password: -or- Type the hotkey to suspend the conn ection: Ctrl + z share Connect to a serial or au xiliary port as an addi tional, read/write user. Syntax: --:- topology cli-> share < port_name > Example: --:- topology cli-> share 77 -77-70-p-2 Displays the f ollowing[...]

  • Page 21

    Chapter 1: Introduction, Navigati on and Commands 11 NOTE: Y ou must log into the CLI as root to have full c ontr ol over the local directory p ath. All normal FTP commands apply . scp Perform a secure shell copy. Syntax: --:- units cli-> scp [[ user @ ] host1 :] file 1 [...] [[ u ser @] host2 :] file2 set Set a paramete r. Syntax: --:- units cl[...]

  • Page 22

    12 Cyclades ACS 6000 Advanced Console Server Command Reference Guide show/ls Show the available director ies, commands or paramete rs at the current location. Syntax: --:- units cli-> show -or- --:- units cli-> ls Example: --:- units cli-> show user _profile user_profile change_password/ --:- units cli-> power_cycle, power_o ff and powe[...]

  • Page 23

    Chapter 1: Introduction, Navigati on and Commands 13 --:- units cli-> cd power_ma nagement/management/ < PDU_ID > /outlet_table --:- outlet_table cli-> [ cycle | on | of f | lock | unlock ] <outlet_number[,..,outlet_nu mber]> Examples: --:- units cli-> cd power_management /managem ent/myPD U/outlet _table --:- outlet_table cli-[...]

  • Page 24

    14 Cyclades ACS 6000 Advanced Console Server Command Reference Guide FOOD HUGH SKI ALMA LURK BRAD S pecial Multi-session Commands The following commands require navigation to an enabl ed and configu red port to which one or more users are simultaneously connected. To get to the port , enter the follow ing command. --:- units cli-> cd topology /&[...]

  • Page 25

    Chapter 1: Introduction, Navigati on and Commands 15 --:- units cli -> inspectdbu f overview/appliance_data_logging The following commands are available for inspectdbuf: • Return - Scroll forward one line. • Ctrl + F - Scroll forward one window . • Ctrl + B - Scroll backward o ne window . • /pattern - Search foward in the file for the fi[...]

  • Page 26

    16 Cyclades ACS 6000 Advanced Console Server Command Reference Guide CLI Equivalent Actions to W eb Manager Check box Selection NOTE: The following example procedure, which configures IP v6, illustrates the actions to use in the CLI to enable or disable an option when a checkbox woul d be selected or deselected in the Web Manager . T o configure IP[...]

  • Page 27

    Chapter 1: Introduction, Navigati on and Commands 17 [X] get_domain_from_ dhcpv6 8. Enter commit .[...]

  • Page 28

    18 Cyclades ACS 6000 Advanced Console Server Command Reference Guide[...]

  • Page 29

    19 CHAPTER 2 Port Access and Configuration Examples By default, all serial ports an d the AUX/Modem port are disabled. The administrator must enable and configure the ports before any one can use them. Con figuration of ports differs based on the type of connected devi ce, whi ch can be either a device consol e, a PDU or modem. By default, all user[...]

  • Page 30

    20 Cyclades ACS 6000 Advanced Console Server Command Reference Guide V iew Information About the Co nsole Server and Connected Devices When a regular user or an administrator enters show at the Topology level, information about the following appears in the form at shown in Table 2.2: • The console server • The AUX/Modem port (if it is enabled a[...]

  • Page 31

    Chapter 2: Port Access and Conf iguration Examp les 21 T o view informati on abou t the console server and connec te d devices: 1. Log into the CLI and enter cd topo logy to change to th e T opology level. --:- units cli-> cd topology Please wait -- this could ta ke a while 2. Enter show . Information ab out the console server and the ports the [...]

  • Page 32

    22 Cyclades ACS 6000 Advanced Console Server Command Reference Guide name: myPDU port: 3/1 type: PM20i|30A status: 3|20 action: 77-77-70-p-1/ 77-77-70-p-2/ myPDU/ --:- topology cli-> Connect to a Device Console Connected to a Serial Port The following procedure is an exam pl e of how an admin istrat or or an authorized user can connect to a devi[...]

  • Page 33

    Chapter 2: Port Access and Conf iguration Examp les 23 Last login: Tue Oct 2 13:09 :04 2007 on :0 Linux fremont-techpubs 2.6.1 5-28-386 #1 PREEMPT Wed Jul 18 22:50:32 UTC 2007 i68 6 GNU/Linux # Manage Power for a Device Connect ed to an Outlet on a PDU See power_cycle, power _off and power_on on page 12 fo r how an admi nistrator or an y authorized[...]

  • Page 34

    24 Cyclades ACS 6000 Advanced Console Server Command Reference Guide 8. Enter set port_settings/seria l_profile=cas then enter comm it as shown to assign the CAS profile and save the settings. --:- port_settings cli-> set port_se ttings/ serial_profile=cas **:- port_settings cli-> commit --:- port_settings cli-> 9. Enter set port_settings/[...]

  • Page 35

    Chapter 2: Port Access and Conf iguration Examp les 25 6. T ype set port_settings/ then press Ta b to vi ew the opt ions fo r the Port_Settings parameter . --:- port_settings cli-> set port_se ttings/ < Tab > rj45_pin-out status serial_profile 7. Enter set port_settings/ status=enabled serial_prof ile=power then enter commit to set the Ser[...]

  • Page 36

    26 Cyclades ACS 6000 Advanced Console Server Command Reference Guide[...]

  • Page 37

    27 CHAPTER 3 CLI Appliance Settings Options This chapter describes the Appliance Sett ing s options. Only administrators and authori zed users can access the appliance_settings level. The se procedures assume y ou have logged into the CLI as an administrator and are at the --:- units cli-> prompt. NOTE: In the tables that show output from the sh[...]

  • Page 38

    28 Cyclades ACS 6000 Advanced Console Server Command Reference Guide See Table 3.1 through Table 3.13 for options available at each le vel and their default settings, where applicable. Parameters with an X beside the m were selected, either as the default or from the previous configuration. Appliance_Settings/Global_Settings 1. Enter cd appliance_s[...]

  • Page 39

    Chapter 3: CLI Appliance Sett ings Options 29 Appliance_Settings/Network 1. Enter cd appliance_settings/n etwo rk to navigate to the Network le vel. --:- units cli-> cd appliance_settin gs/netwo rk 2. Enter show to view the list of available options. string_9 = string_10 = sensors current_temperature: (deg_c, display only) maximum_temperature_(d[...]

  • Page 40

    30 Cyclades ACS 6000 Advanced Console Server Command Reference Guide [X] enable_ipv6 (enable d by default) [ ] get_dns_from_dhcpv6 [ ] get_domain_from_dhcpv6 devices eth0 settings status=enabled/disabled (*) ipv4_method (*) dhcp ( )static address: nnn.nnn.nnn.nnn mask: nnn.nnn.nnn.nnn ( ) ipv4_unconfigured ( )ipv6_method (*) stateless ( ) dhcpv6 ( [...]

  • Page 41

    Chapter 3: CLI Appliance Sett ings Options 31 mask: nnn.nnn.nnn.nnn ( ) ipv4_unconfigured ( ) ipv6_method (*) stateless ( ) dhcpv6 ( ) static ( ) address / prefix_length ( ) ipv6_unconfigured mac address: (information only) bonding bonding with eth0 as primary and eth1 as second mode of access mii mon (milliseconds) = 100 (default) up delay (millis[...]

  • Page 42

    32 Cyclades ACS 6000 Advanced Console Server Command Reference Guide IPv6 IPv4 addresses are always enabled. An administ rator can also enable IPv6 addresses at the appliance_settings/netw ork/ipv6 level. A procedure to enable IPv6 is us ed as an example in CLI Equivalent Actions to Web Manager Checkbox Selection on page 16 . Devices The procedure [...]

  • Page 43

    Chapter 3: CLI Appliance Sett ings Options 33 --:- settings cli-> show Host s The following procedure describes how to add a host to the hosts table. T o add a host to the host table: 1. Enter cd appliance_settings/netwo rk/hosts to navigate to the Hosts level. --:- units cli-> cd appliance_settin gs/netwo rk/hosts 2. Enter show to view the c[...]

  • Page 44

    34 Cyclades ACS 6000 Advanced Console Server Command Reference Guide alias: 127.0.0.1/add 172.26.31.164/ 7. Enter cd <IP_address>/settings to navigate to the level where you can perform add itio nal configuration of the host entry . --:- hosts cli-> cd 172.26.31.164/se ttings 8. Enter show to view the additions to the host table and the Se[...]

  • Page 45

    Chapter 3: CLI Appliance Sett ings Options 35 ( ) static address = prefix_length = gateway = (*) ipv6_address_unc onfigured mac address: 00:e0:86:0c :49:7a dns: primary = 172.26.29.4 dns: primary = 172.26.29.4 secondary = domain = corp.avocent.co m hostname = ACS6016-02700 95142 Some basic and useful keys a re: - tab (once/twice) - shows the next p[...]

  • Page 46

    36 Cyclades ACS 6000 Advanced Console Server Command Reference Guide Appliance_Settings/Port s Enter cd appliance_se ttings/ports to navigate to the Po rts level. --:- units cli-> cd applianc e_settings/ports T able 3.3: Ports Options Ports Navigation T ree physical_ports serial_ports auxiliary_ports cas_profile default_settings general alerts d[...]

  • Page 47

    Chapter 3: CLI Appliance Sett ings Options 37 T o enable and assign the Serial prof ile to a serial port: 1. Enter cd appliance_se ttings/ports/physic al _ports/serial_ports/ <n > /port_settings to navigate to the ports_settin gs le vel. Po rt 3 is used in the exam ple. --:- units cli-> cd appliance_settin gs/ports /physica l_ports/ serial[...]

  • Page 48

    38 Cyclades ACS 6000 Advanced Console Server Command Reference Guide --:- port_settings cli-> set port_se ttings/ status=enabled serial_profile=cas **:- port_settings cli-> commit --:- port_settings cli-> T o enable and configu re the AUX/Modem port: 1. Enter cd appliance_se ttings/ports/physi c al_ports/auxiliary_ports/ttym1/ aux_port_ se[...]

  • Page 49

    Chapter 3: CLI Appliance Sett ings Options 39 --:- units cli-> cd appliance_settin gs/ports /dial-in _profile -or- --:- units cli-> cd appliance_settin gs/ports /power_p rofile Appliance_Setti ngs/Pluggable Devices Enter cd appliance_settings/p luggable_devices to navigate to the pluggable_dev ices level. --:- units cli-> cd applianc e_set[...]

  • Page 50

    40 Cyclades ACS 6000 Advanced Console Server Command Reference Guide Appliance_Setti ng s/Authentication Enter cd appliance_se ttings/authenticati on to navigate to the authentication level. --:- units cli-> cd applianc e_settings/authentication NOTE: Kerberos does not work unless the adm in istrator copies th e /etc/krb5.keyt ab file from the K[...]

  • Page 51

    Chapter 3: CLI Appliance Sett ings Options 41 Appliance_Settings/Users Enter cd appliance_settings/u sers to naviga te to the users lev el. --:- Units cli-> cd applianc e_settings/users T o add a user and p assword: 1. Enter cd appliance_settings/u sers/local_accounts/user_names t o n avigate to the user_names level. --:- units cli-> cd appli[...]

  • Page 52

    42 Cyclades ACS 6000 Advanced Console Server Command Reference Guide --:- user_names cli-> add --:#- [user_name] cli-> set user_information / user_name=fred password=smith123abc confirm _password=smith123abc --:#- [user_names] cli-> 3. Enter save . --:#- [user_names] cli-> save 4. Enter show to verify that the new user has been added. -[...]

  • Page 53

    Chapter 3: CLI Appliance Sett ings Options 43 NOTE: T o set a rule, you must enable the interface, set the rule for the in terfac e and physically connect the interface to the network. Appliance_Setti ngs/IPSec(VPN) Enter cd appliance_settings/ipse c(vpn) to navigate to the ipsec(vpn) level. --:- units cli-> cd applianc e_settings/ipsec(vpn) T a[...]

  • Page 54

    44 Cyclades ACS 6000 Advanced Console Server Command Reference Guide Appliance_Settings/SNMP Enter cd appliance_se ttings/snmp to navigate to the snmp leve l. --:- units cli-> cd applianc e_settings/snmp ip_address = next_hop = subnet = ipsec(vpn)_authentication authentication_method ( ) rsa_key remote_side_rsa = local_side_rsa = ( ) secret pre-[...]

  • Page 55

    Chapter 3: CLI Appliance Sett ings Options 45 Appliance_Settings/Date and T ime Enter cd appliance_settings/d ate_and_time to navigate to the date_and_time level. --:- units cli-> cd applianc e_settings/date_and_time ( ) version v1/v2 ipv6 source ( ) version v3 authentication_type md5 sha authentication_pass_phrase des_pass_phrase minimum_authen[...]

  • Page 56

    46 Cyclades ACS 6000 Advanced Console Server Command Reference Guide Appliance_Settings/ Boot Configuration Enter cd appliance_se ttings/boot_co nfi guration to navigate to the boot_configuration level . --:- units cli-> cd applianc e_settings/boot_configuration hour = minute = second = time_zone (*) predefined zone = utc ( ) define name = acron[...]

  • Page 57

    Chapter 3: CLI Appliance Sett ings Options 47 Appliance_Settings/Online Help Enter cd appliance_settings/o nlin e_help to navigate to the online_help level. --:- units cli-> cd applianc e_settings/online_help T o set the online help URL: Perform this pro cedure if you have downloaded the online help files to a web server that is accessible to th[...]

  • Page 58

    48 Cyclades ACS 6000 Advanced Console Server Command Reference Guide[...]

  • Page 59

    49 CHAPTER 4 CLI Overview , Information, Active Sessions and Power Management Options This section provides procedures for some t asks th at the administrator can perform at the following levels of the CLI. Only administrators and authorized users can access the Information, Active Sessions and Power Management levels. Overview Options T o view and[...]

  • Page 60

    50 Cyclades ACS 6000 Advanced Console Server Command Reference Guide Information Options T o view and perform Info rmat ion options: 1. Log onto the CLI as an administrator and change to the inform atio n level. --:- units cli-> cd information --:- information cli-> 2. Enter show to view the In formation options --:- information cli-> show[...]

  • Page 61

    Chapter 4: CLI Overview, Informat ion, Active Sessions and Power Ma nagemen t Options 51 3. Enter cd < navigation option fr om list > to view any of the options. 4. Enter show to view the list of available parameters. This procedure continues d own th e hierarchical levels. See Table 4.3 for the options and and their default settings. T able [...]

  • Page 62

    52 Cyclades ACS 6000 Advanced Console Server Command Reference Guide inactive Size: 83344 kB mapped Size: 14844 kB memfree Size: 1 19404 kB memtotal Size: 257436 kB nfs_unstable Size: 0 kB pagetables Size: 1000 kB slab Size: 5812 kB sreclaimable Size: 2572 kB sunreclaim Size: 3240 kB swapcached Size: 0 kB swapfree Size: 0 kB swaptotal Size: 0 kB vm[...]

  • Page 63

    Chapter 4: CLI Overview, Informat ion, Active Sessions and Power Ma nagemen t Options 53 Active Sessions Information The Active Session information fields are described in Table 4.4. An authorized user can kill an active session with th e Kill command. T o view and kill Active_Sessions : 1. From the units level CLI prompt, enter cd active_sessions [...]

  • Page 64

    54 Cyclades ACS 6000 Advanced Console Server Command Reference Guide --:- active_sessions cli-> kill 37 Power Management Options The Power Management Options are described in Table 4.5. T o rename a PDU: 1. Log onto the CLI as an administrator and enter cd power_management/se ttings to navigate to the settings level. --:- units cli-> cd power[...]

  • Page 65

    55 Appendices Appendix A: Enabling Firmware Upgrades When the Boot Image is not in Flash T o enable firmware upg rades when the boot image is not in Flash: 1. Connect to the console of the console server as root. CLI 2.0 (2007-10-04T08:11-07 00) --:- units cli-> 2. Enter shell . A warning appears fo llow ed by the root prompt. --:- units cli->[...]

  • Page 66

    56 Cyclades ACS 6000 Advanced Console Server Command Reference Guide Appendix B: T echnical Support Our Technical Support staff is ready to assist you with any installati on or op erating issues you encounter with your Avocent produ ct. If an issue should develo p, follow the steps below for the fastest possible service. T o resolve an issue: 1. Ch[...]

  • Page 67

    57 INDEX Index A access options (CLI) 3 add command 7 Appliance Settings options 27 autocompletion 5 AUX/Modem port configure 19 enable 38 C CAS Profile 20 , 22 cd command 8 cleandbuf command 15 CLI utility access options 3 introduction 1 log in 3 navigation 4 command line syntax 6 command set 7 commit comman d 11 connect command 9 connect to a ser[...]

  • Page 68

    58 Cyclades ACS 6000 Advanced Console Server Command Reference Guide on command 12 opiepasswd command 13 outlet groups 54 Overview options 49 P parameters 6 passwd command 13 PC cards, configure 39 PDUs AUX/Modem port connection 2 manage power on outlets 19 manage power, procedure 24 ports for 1 power management and configu rati on op tion s 54 pow[...]

  • Page 69

    FCC Warning Statement The Cyclades ACS advanced console server has been tested and found to comply with the limits for Class A digital devices, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment gener[...]

  • Page 70

    For T echnical Support : www.avocent.com/support 590- 7 70 -50 1B C yclades ® ACS 6000 Installation/Administration/User Guide[...]