Go to page of
Similar user manuals
-
Network Card
B&B Electronics 3PXCC1b
25 pages 0.75 mb -
Switch
B&B Electronics EIR508-2SC-T
2 pages 0.12 mb -
Network Card
B&B Electronics MESR9xx
61 pages 1.73 mb -
Home Theater Server
B&B Electronics Wireless 802.11b Serial Server ESR901WB
1 pages 8.96 mb -
Computer Hardware
B&B Electronics PES1A
31 pages 0.41 mb -
Network Card
B&B Electronics Parallel Printer Card PIOC
16 pages 0.27 mb -
Stereo System
B&B Electronics FG9026
1 pages 0.18 mb -
Switch
B&B Electronics EIR510 Series
2 pages 0.11 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of B&B Electronics FBDA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of B&B Electronics FBDA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of B&B Electronics FBDA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of B&B Electronics FBDA should contain:
- informations concerning technical data of B&B Electronics FBDA
- name of the manufacturer and a year of construction of the B&B Electronics FBDA item
- rules of operation, control and maintenance of the B&B Electronics FBDA item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of B&B Electronics FBDA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of B&B Electronics FBDA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the B&B Electronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of B&B Electronics FBDA.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the B&B Electronics FBDA item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Documentat ion Number FBDA0797 M anual Cover Page B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 Strain Gauge/Load Cell Bridge Amplifier Model FBDA Docum ent ation Nu m ber FBDA 0797 This product Designed and M anufactured In Ottawa, Illinois USA of domest ic and import ed parts by B&B Electron[...]
-
Page 2
Documentat i on Num ber FBDA0797 Manual Table of Content s i B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 TABLE OF CONTENTS CHAPTER 1: INTRODUCTION.................................................................1 F EATURES .........................................................................[...]
-
Page 3
Documentat ion Number FBDA0797 M anual 1 B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 Chapter 1: Intr oduction Features The FBDA is a s ignal conditioning module that allows you to measure voltages produced by full- bridge sensor s using a data acquisition module. This module can condition signal[...]
-
Page 4
2 Documentation Number FBDA 0797 M anual B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 Packing List Examine the shipping ca rton and the contents for physical damage. The following items should be in the s hipping carton: 1. FBDA module 2. This inst ruction manual If any of these items ar e damage[...]
-
Page 5
Documentat ion Number FBDA0797 M anual 3 B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 Chapter 2: Connections Power Supply Connections The FBDA module requires 13 to 18VDC @ 10mA. Model 232PS2 available from B&B Electr onics is recommended. Although the 232PS2 is a 12VDC power supply , it outp[...]
-
Page 6
4 Documentation Number FBDA 0797 M anual B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 Data Acquisition Connec tions The connections to the Data Acquisition Module are made through a DB-25 (male) connector. The F BDA is pin compatible with B&B Electronics ’ SDAXX, and ADIO12 modules. This al[...]
-
Page 7
Documentat ion Number FBDA0797 M anual 5 B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 Figure 2.1: Block Di agram of FBDA Connecti ons A / D Note: Conditioned signal is available on DB-25 pin #8 6 4 5 Terminal Blocks 2 3 1 +13V A/D 1 +13V REF+ GND GND 19 19 REF- DB-25P Connector GND GND Vout Modul[...]
-
Page 8
Documentat ion Number FBDA0797 M anual 7 B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 Chapter 3: Gain Selection The FBDA has sev eral different gain settings to provide the largest poss ible voltage range for an A/D conv erter. The gain of the FBDA is selec ted using a jumper, 6 jumper pins (labe[...]
-
Page 9
8 Documentation Number FBDA 0797 M anual B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 Sensors that inc orporate bridge c ircuitry usually have noticeable zero offs ets. This s hould be considered when tak ing measurements and deter mining gain. The easiest way to solve this problem is to calibr a[...]
-
Page 10
Documentat ion Number FBDA0797 M anual 9 B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 Chapter 4: Excitation V o ltage Sensors that ar e based on a Wheatstone bridge need an excitation voltage to ex cite the bridge. The FBDA prov ides an adjustable excitation v oltage. This exc itation voltage is [...]