Go to page of
Similar user manuals
-
Home Security System
Banner American Products GEO
16 pages 0.44 mb -
Work Light
Banner American Products 150-3W
2 pages 0.2 mb -
Work Light
Banner American Products R150-3M
2 pages 0.2 mb -
Laminator
Banner American Products PL100 PL150
2 pages 0.7 mb -
Stud Sensor
Banner American Products S18M
8 pages 1.34 mb -
Laminator
Banner American Products PL135-4
2 pages 0.01 mb -
Work Light
Banner American Products 150-3M
2 pages 0.2 mb -
Network Card
Banner American Products Wireless Network
32 pages 3.9 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Banner American Products EDGE, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Banner American Products EDGE one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Banner American Products EDGE. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Banner American Products EDGE should contain:
- informations concerning technical data of Banner American Products EDGE
- name of the manufacturer and a year of construction of the Banner American Products EDGE item
- rules of operation, control and maintenance of the Banner American Products EDGE item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Banner American Products EDGE alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Banner American Products EDGE, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Banner American Products service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Banner American Products EDGE.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Banner American Products EDGE item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Printed in USA 12/04 P/N 118000 rev . A Models included: • GEO • EDGE[...]
-
Page 2
2 P/N 118000 rev . A Banner Engin eering Corp. • Minneapolis, MN U.S.A. www .bannerengineering.com • T el: 763.544.3164 W ARNING . . . Not T o Be Used for Per sonnel Protect ion Never use this produc t as a sensing device for person nel protection. Doin g so could lead to serious injury or death. This produc t does NOT i nclude the self-chec ki[...]
-
Page 3
P/N 118000 rev . A 3 Banner Engin eering Corp. • Minneapolis, MN U.S.A. www .bannerengineering.com • T el: 763.544.3164 Introducing PresencePLUS P4 The PresencePLUS P4 (or the Sensor) is an easy-to-use vision sensor with advanced visual inspection capabilities. With minimal knowledge of vision, a user can quickly set up the Sensor to run an ins[...]
-
Page 4
4 P/N 118000 rev . A Banner Engin eering Corp. • Minneapolis, MN U.S.A. www .bannerengineering.com • T el: 763.544.3164 components/ connections components/ connections Cable Connections 1. If a light will be powered by the Sensor , connect it to the 3-pin Light connector . a. Caution: If the light is powered by the Sensor , the Sensor power sou[...]
-
Page 5
P/N 118000 rev . A 5 Banner Engin eering Corp. • Minneapolis, MN U.S.A. www .bannerengineering.com • T el: 763.544.3164 Light Connector (Banner lights only) 1 = Brown 24V 2 = n/a 3 = Blue (ground) 4 = Strobe Ethernet NTSC Video to Monitor 12-pin Discrete I/O Power/Ground RS-232 Serial (see pin assignments below) components/ connections componen[...]
-
Page 6
6 P/N 118000 rev . A Banner Engin eering Corp. • Minneapolis, MN U.S.A. www .bannerengineering.com • T el: 763.544.3164 sensor configuration sensor configuration T ypical IP Address: 192.168.0.2 step 3 step 3 PC Configuration 1. Ethernet communication, configure the IP address of your computer . 2. Install the PresencePLUS software a. Insert th[...]
-
Page 7
P/N 118000 rev . A 7 Banner Engin eering Corp. • Minneapolis, MN U.S.A. www .bannerengineering.com • T el: 763.544.3164 sensor startup sensor startup step 5 step 5 Launching Software 1. Start the PresencePLUS program by clicking Start > Program Files > PresencePLUS . 2. At start-up, PresencePLUS P4 will try to communicate with the Sensor [...]
-
Page 8
8 P/N 118000 rev . A Banner Engin eering Corp. • Minneapolis, MN U.S.A. www .bannerengineering.com • T el: 763.544.3164 Software Setup Use the Main Menu toolbar to navigate the PresencePLUS P4 options. Proceeding from left to right, the buttons in the Menu toolbar step through the process of creating an inspection file. Inspection W ork Flow st[...]
-
Page 9
P/N 118000 rev . A 9 Banner Engin eering Corp. • Minneapolis, MN U.S.A. www .bannerengineering.com • T el: 763.544.3164 T ool Options NOTE: T ool availability depends on P4 model. creating inspections creating inspections This screen automatically configures the parameters chosen in the T ools screen. a. Choose the sample size b. Click Start c.[...]
-
Page 10
10 P/N 118000 rev . A Banner Engin eering Corp. • Minneapolis, MN U.S.A. www .bannerengineering.com • T el: 763.544.3164 running inspections running inspections Viewing Results Display Options Select an inspection to run, and view the results of the inspection. T o select an inspection, (in the Select tab) enable Software Override and select th[...]
-
Page 11
P/N 118000 rev . A 11 Banner Engin eering Corp. • Minneapolis, MN U.S.A. www .bannerengineering.com • T el: 763.544.3164 sensor configuration sensor configuration step 7 step 7 System Setup Use the System Setup screen to change discrete I/O, the communication port, the product change, the strobe output (for external lighting control), the trigg[...]
-
Page 12
12 P/N 118000 rev . A Banner Engin eering Corp. • Minneapolis, MN U.S.A. www .bannerengineering.com • T el: 763.544.3164 Maintenance Maintenance tasks include keeping the hardware free of dust and dirt and updating the PresencePLUS software as new versions become available. Cleaning the Sensor Regularly remove any accumulated dust or dirt from [...]
-
Page 13
P/N 118000 rev . A 13 Banner Engin eering Corp. • Minneapolis, MN U.S.A. www .bannerengineering.com • T el: 763.544.3164 sensor t roubleshooting sensor t roubleshooting T roubleshooting Problem Cause/Solution • Error Code is displayed on PC. • A list of error codes and potential causes and solutions are available under Help/About on the Pre[...]
-
Page 14
14 P/N 118000 rev . A Banner Engin eering Corp. • Minneapolis, MN U.S.A. www .bannerengineering.com • T el: 763.544.3164 Specifications Models Right-Angle In-Line GEO: P4GR EDGE: P4ER GEO: P4GI EDGE: P4EI Part Numbers GEO: 71431 EDGE: 73599 GEO: 71432 EDGE: 73600 Dimensions * Measured length does not include connectors or cables H x W x L: 55.6[...]
-
Page 15
P/N 118000 rev . A 15 Banner Engin eering Corp. • Minneapolis, MN U.S.A. www .bannerengineering.com • T el: 763.544.3164 Memory Stores up to 12 inspection files Power Voltage: 10-30V dc Current: 500 mA max. Acquisition 500 frames per second max. Image size: 126 x 98 pixels Levels of Gray Scale: 256 Imager 2.56 x 2.06 mm, 3.25 mm diagonal CMOS P[...]
-
Page 16
Ba nn er En gi ne eri ng Co rp ., 97 14 T en th Av e. No . Mi nn ea po li s, MN 5 54 41 Ph on e: 7 63 .5 44. 31 64 ww w .b an ne re ng in ee rin g. co m Em ai l: se ns or s@b an ne re ng in ee rin g. co m P/N 118000 rev . A Models/T ools PresencePLUS P4 Models User’ s Manual Part Number* T ools Locate GEO Find GEO Count Edge Object Measure T est [...]