A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Barco MGD 2621, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Barco MGD 2621 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Barco MGD 2621. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Barco MGD 2621 should contain:
- informations concerning technical data of Barco MGD 2621
- name of the manufacturer and a year of construction of the Barco MGD 2621 item
- rules of operation, control and maintenance of the Barco MGD 2621 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Barco MGD 2621 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Barco MGD 2621, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Barco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Barco MGD 2621.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Barco MGD 2621 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Inst allation & User Manual MGD 2621 P Medical Greyscale Display[...]
-
Page 2
W arning This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. © 2001 BARCO nv . Allright s reserved.[...]
-
Page 3
MGD 2621 P User's Guide 3 • Read the safety and operating instructions before operating the apparatus. • Retain safety and operating instructions for future reference. • Adhere to all warnings on the apparatus and in the operating instructions manual. • Follow all instructions for operation and use. •This apparatus conforms to: IEC60[...]
-
Page 4
MGD 2621 P User's Guide 4 CONTENTS Introduction ........................................................................................................ 5 Overview ...................................................................................................... 5 About the manuals ..........................................................[...]
-
Page 5
Introduction 5 Overview INTRODUCTION Resolution and bandwidths The BARCO MGD 2621 P is a high-resolution greyscale portrait display . It s outstanding visual performance, combining a 2 MegaPixel resolution with a very high brightness, makes it ideal for medical imaging and many other medical and scientific applications. The MGD 2621 P is comp atibl[...]
-
Page 6
Introduction 6 The conformity calibration, as well as the complete adjustment of the display , can be performed by means of the remote, user-friendly MediCal® software package. MediCal, which runs under Microsoft Windows NT , is especially developed to adjust and check BARCO’s medical displays. A lot of adjustments can also be done on the monito[...]
-
Page 7
Installation 7 • Keep your original packaging. It is designed for this display and is the ideal protection during transport. • Do not lift the display all by yourself to avoid injury . • Avoid reflections in the picture tube to reduce eye strain. • Place the display on a strong and stable t able or desk if used as desktop display . • Keep[...]
-
Page 8
Installation 8 The display is packed in a box on a pallet. T o unpack: 1. Cut the ribbons around the box by means of a pair of wire-cutters. 2. Lift the box from the pallet. The display remains standing on the pallet. 3. Remove the Accessory box and the upper polystyrene piece. 4. Remove the plastic bag from the display . 5. Lift the display out of[...]
-
Page 9
Installation 9 SENSOR CONTRAST BRIGHTNESS REMOTE OUT REMOTE IN VIDEO HS / CS VS Location of controls and connectors 10 9 8 7 6 5 4 1 2 3 {1} Optical sensor plug {2} Contrast knob {3 } Brightness knob {4 } Remote (RS-232) output {5} Remote (RS-232) input {6} Video input {7} Horizontal / composite sync. input {8} V ertical sync. input {9} Power input[...]
-
Page 10
Installation 1 0 The connected equipment must comply to all relevant safety demands. Important: The use of low-quality video cables can distort the video signal and influence diagnosis. 1. Check the termination impedance of the display’s video input and the impedance of the imaging board that produces the video signals you want to connect. Y ou c[...]
-
Page 11
Installation 1 1 The display can be controlled remotely by a computer through the serial data bus. A typical example of this, is the MediCal software that controls the display . MediCal runs on a PC that is connected through the serial data bus. This PC is not necessarily the same computer as the one that produces the video signals. Unlike the vide[...]
-
Page 12
Installation 1 2 Import ant considerations • The best environment for diagnostic imaging is one with controlled and dimmed ambient light. The human eye's sensitivity depends on the ambient light strength. It is most sensitive to small contrast changes (or subtle image details) at limited ambient light levels. • The best ambient light level[...]
-
Page 13
Operation 13 Press the Power button {10} on the rear panel to switch on the display . Note: The display can be switched of f by the automatic power saving system. This is indicated by the green LED. The LED is ON when the display is in stand-by . OPERA TION: USER CONTROLS How to switch on the display How to use the automatic power saving system The[...]
-
Page 14
Operation 14 Note: When you change the contrast (brightness) control one step at the time (click per click), the picture contrast (brightness) will change although the cursor on the OSD does not move. This is because contrast (brightness) can be adjusted in more than 4000 steps, and the OSD is only 6 inches wide. Advised setting for contrast and br[...]
-
Page 15
Advanced Adjustments 15 ADV ANCED ADJUSTMENTS (FOR SERVICE ST AFF ONL Y) The MediCal software The display is actually designed to be adjusted by means of MediCal. MediCal provides a very user- friendly way to control and adjust the display . Even more, you need MediCal to automatically calibrate the display . The on-screen menu system Especially fo[...]
-
Page 16
Advanced Adjustments 16 To exit the menu system: 1 T urn the Contrast knob until the Save Changes dialog appears in the OSD: 2 T urn the Brightness knob to toggle between Y es and No. Select Y es to save the changes, select No to exit without saving the changes. 3 T urn the Contrast knob to exit. See also: Menu Exit, later in this chapter . A word [...]
-
Page 17
Advanced Adjustments 17 1 T urn the Brightness knob once to enter the Focus menu. The first focus adjustment appears: S tatic Focus. 2 T urn the Brightness knob to adjust static focus. S tatic focus has effect on the complete screen. 3 T urn the Contrast knob to switch to the next focus adjustment. This is the first of 9 zone- dependent focus adjus[...]
-
Page 18
Advanced Adjustments 18 T urn the Contrast knob to switch to the next menu. This is the display type. This is the display's serial number This is the display's order number . The order number of the internal software. The internal software version. The total operating time since production. The currently selected scan mode. Info If your d[...]
-
Page 19
Advanced Adjustments 19 Miscellaneous T urn the Brightness knob to toggle the Backporch clamping between Off and On. The normal setting is: Off. If Backporch clamping is switched off, clamping is on the sync tip. IMPORT ANT : Improper setting of the Backporch clamping can result in incorrect luminance output. T urn the Brightness knob to toggle the[...]
-
Page 20
Advanced Adjustments 20 Menu exit 1 T urn the Brightness knob to enter the Exit menu. The Save Changes dialog appears. 2 T urn the Brightness knob to toggle between Y es and No. Select Y es to save the changes, select No to exit without saving the changes. 3 T urn the Contrast knob to exit. Note : A number of settings and adjustments are saved dire[...]
-
Page 21
Maintenance 21 MAINTENANCE Picture tube The glass panel of the picture tube is handled with a special coating. T ake care not to damage or scratch the coating. Clean the picture tube with a soft woollen or cotton cloth. The cloth should be moist, not wet! Use a watery solution or a mild commercial glass cleaning solution. Apply (e.g., spray) the so[...]
-
Page 22
T roubleshooting 22 TROUBLESHOOTING There appears no image on the picture tube, the green LED on the front is out • Check if the power cord is properly connected to the power outlet and to the display . • Check if the power button is depressed. • Check if contrast and brightness are not set to 0. There appears no image on the picture tube, th[...]
-
Page 23
Background information 23 APPENDIX A: BACKGROUND INFORMA TION Clamping Inside the display , the video signal from the video input is connected to the video amplifier . This circuit amplifies the signal, paying special attention to two signal levels: the amplitude and the dc-level. The dc-level of the video signal in the video amplifier determines t[...]
-
Page 24
Background information 24 be thicker in the center . BARCO has developed a special system, called Luminance Uniformity Correction (LUC), that solves this problem. The LUC system enhances the light output at the edges of the CRT , so that the luminance there is the same as in the center . The LUC system is calibrated in the factory . From time to ti[...]
-
Page 25
T echnical specifications 25 Picture tube: Faceplate transmission: +/- 33% Faceplate type: ARC panel Image representation: portrait Phosphor: P45 Light output: Calibrated: 300 cd/m² Peak: 600 cd/m² Resolution: Max. adress. pixels: 1280 Max. adress. lines: 1600 Scanning systems Horizontal scanning: Multi sync: -controller controlled Minimum fre[...]
-
Page 26
MGD 2621 P User's Guide 26[...]
-
Page 27
B410030 /Rev . 00 February 2001 Printed in Belgium BarcoView Theodoor Sevenslaan 106 8500 Kortrijk, Belgium Phone: +32(0)56 23 32 44 Fax: +32(0)56 23 33 74 E-mail: sales.medical@barco.com http://www .barcoview .com BarcoView Inc 3059 Premiere Parkway Duluth, Georgia, 30097,USA Phone: +1 678 475 8000 Fax: +1 678 475 8100 E-mail: sales.medical@barco.[...]