Go to page of
Similar user manuals
-
Projection Module
Barco OV-D2
16 pages 2.23 mb -
Display Panel
Barco ADP361
4 pages 0.64 mb -
Projector
Barco R9002110
55 pages 2.17 mb -
Stereo System
Barco 26-0501000-00
186 pages 0.76 mb -
Wheelchair
Barco R9000893
55 pages 2.1 mb -
Multi Video Insertion Unit
Barco Hydra
4 pages 0.61 mb -
Display Stations
Barco iSurveillance
12 pages 2.18 mb -
Display Wall
Barco XDS-1000
6 pages 2.16 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Barco MGD 521 M, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Barco MGD 521 M one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Barco MGD 521 M. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Barco MGD 521 M should contain:
- informations concerning technical data of Barco MGD 521 M
- name of the manufacturer and a year of construction of the Barco MGD 521 M item
- rules of operation, control and maintenance of the Barco MGD 521 M item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Barco MGD 521 M alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Barco MGD 521 M, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Barco service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Barco MGD 521 M.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Barco MGD 521 M item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Inst allation & User Manual MGD 521 M MGD 521 MKII Medical Greyscale Displays V599326/Rev . 02 June 2003 BarcoView Theodoor Sevenslaan 106 8500 Kortrijk, Belgium Phone: +32(0)56 23 32 44 Fax: +32(0)56 23 33 74 E-mail: sales.medical@barco.com http://www .barcoview .com BarcoView Inc 3059 Premiere Parkway Duluth, Georgia, 30097,USA Phone: +1 678 [...]
-
Page 2
MGD 521 M - MKII User's Guide 3 © 2003 BARCO nv. All rights reserved. Trademark information TrueGrey, MediCal, BarcoMed, and MeDis are registered trademarks of BARCO NV. Windows NT is a registered trademark of Microsoft Corporation.[...]
-
Page 3
MGD 521 M - MKII User's Guide 4[...]
-
Page 4
MGD 521 M - MKII User's Guide 5 Regulations This apparatus conforms to: IEC601-1, UL2601-1, cUL2601-1, EN 60601-1 This apparatus is classified as Type B without Applied Part. Usage in Hazardous locations Class I equipment Equipment not suitable for use in the presence of a flammable anaesthetic mixture with air or with oxygen o[...]
-
Page 5
MGD 521 M - MKII User's Guide 6[...]
-
Page 6
MGD 521 M - MKII User's Guide 7 CONTENTS 1. Introduction ..................................................................................................... 9 1.1 Overview .................................................................................................. 9 Resolution and bandwidths ............................................[...]
-
Page 7
MGD 521 M - MKII User's Guide 8[...]
-
Page 8
Introduction 9 1. INTRODUCTION 1.1 Overview Resolution and bandwidths The BARCO MGD 521 M and MGD 521 MKII displays are ultra-high resolution, grayscale portrait displays. Their outstanding visual performance, combining a 5 MegaPixel resolution with a very high brightness, makes them ideal for diagnostic imaging and many other medical and scientifi[...]
-
Page 9
Introduction 10 adjust and check BARCOs medical displays. A lot of adjustments can also be done on the monitor itself, by means of an extensive on-screen menu system, accessible from the rear panel controls. Power saving system The MGD 521 displays are equipped with a power saving system. When left idle for a certain time, the computer, connecte[...]
-
Page 10
Installation 11 1.3 About the manuals This guide is meant for people who want to install and use the MGD 521 displays, as well as people who need to install and adjust the displays. Chapter 4, Adjustments, is meant for this second category only, because it describes actions and procedures that require a technical skill to be performed properly. The[...]
-
Page 11
Installation 12 2. INSTALLATION 2.1 Precautions Keep your original packaging. It is designed for this display and is the ideal protection during transport. Do not lift the display all by yourself to avoid injury. Avoid reflections in the picture tube to reduce eye strain. Place the display on a strong and stable table or desk if use[...]
-
Page 12
Installation 13 2.3 Controls and connectors 1 REMOTE OUT REMOTE IN VIDEO HS / CS VS 2 4 5 6 7 8 9 10 11 3 {1} Optical sensor plug {2} Ambient Light Compensation (ALC) sensor (optional) {3} Green power LED {4} Control knob, combination of a push button and a turning knob. The control knob is used for switching the power on/off, and selecting and per[...]
-
Page 13
Installation 14 2.4 Signal connection a) Connection of video signals The connected equipment must comply to all relevant safety demands. Important: The use of low-quality video cables can distort the video signal and influence diagnosis. 1. Check the impedance of the imaging board that produces the video signals you want to connect. It must be 50 o[...]
-
Page 14
Installation 15 b) Connection of data signals The display can be controlled remotely by a computer through the serial data bus. A typical example of this, is the MediCal software that controls the display. MediCal runs on a PC that is connected through the serial data bus. This PC is not necessarily the same computer as the one that produces the vi[...]
-
Page 15
Installation 16 d) Connection of power 1. Power cord: Utilize a UL-listed detachable power cord, 3-wire, type SJ or equivalent, 18 AWG min., rated 300 V min., provided with a hospital-grade type plug 5-15P configuration for 120V application, or 6-15P for 240V application. 2. Plug one end of the power cord into the rear of the display (connector LIN[...]
-
Page 16
Installation 17 Important considerations The best environment for diagnostic imaging is one with controlled and dimmed ambient light. The human eye's sensitivity depends on the ambient light strength. It is most sensitive to small contrast changes (or subtle image details) at limited ambient light levels. The best ambient light level, [...]
-
Page 17
Operation 18 3. OPERATION: USER CONTROLS Important : The best way to adjust and control the display is by using MediCal, which displays the ideal test patterns for correct adjustment. However, in case you do not dispose of MediCal, you can control and adjust the display by means of the built-in On-Screen Display (OSD). 3.1 Switching on / off Power [...]
-
Page 18
Operation 19 3.2 Contrast and brightness control Contrast and brightness can be controlled through the OSD menus. To activate the OSD Turn the control knob {4} from left to right or from right to left. As a result, the OSD main menu appears. Note: The control knob should turn over at least 30 degrees before the OSD becomes visible. Contrast - Contr[...]
-
Page 19
Operation 20 To control contrast manually 1 Turn the control knob to select Contrast in the OSD main menu. 2 Press the control knob shortly. The contrast control menu appears. 3 In the contrast control menu, select Manual contrast adjustment and press the control knob shortly. The contrast scroll bar appears. 4 Turn the control knob until you have [...]
-
Page 20
Operation 21 STATUS INFORMATION Display Name: MGD 521MKII Serial Number: 5114147 Mode Name: New mode Mode H-frequency: 175.32 kHz Mode V-frequency: 79.94 Hz Software Version: V 1.01 Run time: 50 hours White level: 300 cd/m2 Activity timeout 30s SH compensation OFF Actual H-frequency:125.30kHz Actual V-frequency: 80.00 Hz - Exit Example of Status in[...]
-
Page 21
Operation 22 Software Version: The internal software version. Run time: The total operating time since production, including burn-in time. White level: The displays white level or light output after calibration, in calibrated position. Activity timeout : This is the time, expressed in seconds, before the display interrupts the data communication[...]
-
Page 22
Advanced 23 4. ADVANCED SETTINGS AND ADJUSTMENTS (FOR SERVICE STAFF ONLY) Important: The functions and controls described in this chapter can have a serious impact on the performance of the display. They should be touched by trained service staff only! 4.1 Settings SETTINGS INFORMATION - LUC OFF - ALC OFF - Orbiter OFF - Power save ON - Display add[...]
-
Page 23
Advanced 24 Explanation of the Settings menu items LUC: LUC is short for Luminance Uniformity Control. When switched on, the internal waveform processor will modulate the gain of the video amplifier so that the luminance is equal all over the screen (within a tolerance of +/- 5%). The LUC system can be calibrated in the Adjustments menu (see furthe[...]
-
Page 24
Advanced 25 ADJUSTMENTS - Geometry - Focus - ALC - Luminance uniformity - Factory reset - Exit Adjustments menu 4.2 Adjustments a) How to make the adjustments 1 Turn the control knob at the rear from left to right or from right to left to activate the On-Screen Display (OSD) main menu. 2 In the main menu, turn the control knob to select Adjustments[...]
-
Page 25
Advanced 26 Width Horizontal position Height Vertical position Blanking - Blanking left Blanking - Blanking right Blanking - Blanking top[...]
-
Page 26
Advanced 27 Interlacing - Pre correction In most cases you do not need to change this adjustment. You may need to increase this adjustment only when the connected video and sync signal contains an abnormally big number of equalization pulses before the vertical sync (more than 8 lines), resulting in a phase error (geometry distortion) at the bottom[...]
-
Page 27
Advanced 28 SH Compensation: SH Position With SH Compensation on, we advise to use the SH Position control instead of the Horizontal Position control in the Geometry menu. Advanced geometry - Horizontal skewing Advanced geometry - Horizontal bowing Advanced geometry - Horizontal trapezium Advanced geometry - Horizontal parabola Advanced geometry - [...]
-
Page 28
Advanced 29 Advanced geometry - Corner top right Advanced geometry - Corner bottom left Advanced geometry - Corner bottom right Advanced geometry - Linearity & S-correction - Horizontal linearity Advanced geometry - Linearity & S-correction - Horizontal S-corr Advanced geometry - Linearity & S-correction - Vertical linearity[...]
-
Page 29
Advanced 30 Advanced geometry - Advanced bowing & skewing - Horizontal bowing left Advanced geometry - Advanced bowing & skewing - Horizontal bowing right Advanced geometry - Advanced bowing & skewing - Horizontal skewing left Advanced geometry - Advanced bowing & skewing - Horizontal skewing right Advanced geometry - Linearity &[...]
-
Page 30
Advanced 31 Focus Static focus Adjust Static focus to obtain an image as sharp as possible in the center. Focus zone You can adjust the focus in 25 independent zones. Turn the control knob to obtain an image as sharp as possible in the selected zone. Press the control knob to switch to the next zone. ALC (optional) Ambient Light Compensation (ALC) [...]
-
Page 31
Advanced 32 Luminance uniformity This menu allows you to calibrate the display, including the Luminance Uniformity circuit. Proceed as follows: 1 Connect the X-Rite DTP92 sensor and apply the black shield (see chapter "Installation"). 2 Follow the instructions on the screen. Factory reset This function allows you to undo all adjustments y[...]
-
Page 32
Maintenance 33 5. MAINTENANCE Picture tube The glass panel of the picture tube is handled with a special coating. Take care not to damage or scratch the coating. Clean the picture tube with a soft woolen or cotton cloth. The cloth should be moist, not wet! Use a watery solution or a mild commercial glass cleaning solution. Apply (e.g., spray) the s[...]
-
Page 33
Troubleshooting 34 6. TROUBLESHOOTING There appears no image on the picture tube, the green LED at the front is out Check if the power cord is properly connected to the power outlet and to the display. Check if the power button is switched on. There appears no image, the green LED is on The display is switched in Stand-by, manually or by th[...]
-
Page 34
Background information 35 APPENDIX A: BACKGROUND INFORMATION Luminance Uniformity Correction A characteristic (or limitation) of every picture tube (CRT) is that the luminance decreases towards the edge of the screen surface. The decrease is normally 20 to 30 %. This is caused by the shape of the picture tube. Inside the CRT, a so- called electron [...]
-
Page 35
Background information 36 At last, the imaging board delivers no sync signals at all, and the micro-controller switches off all but one power supplies in the display. Only the micro-controller's own supply keeps on running, resulting in a very low power consumption of 5 W. If you start using the computer again, the imaging board switches on bo[...]
-
Page 36
Technical specifications 37 Picture tube: Faceplate transmission: +/- 32% Faceplate type: ARC panel Image representation: portrait Phosphor: P45 (standard) or P104 (option for MGD 521 MKII only) Light output: (P45 phosphor) MGD 521: Calibrated: 300 Cd/m2 MGD 521M: Calibrated: 400 Cd/m2 Peak: 600 Cd/m2 Resolution: Max. adress. pixels: 2048 Max. adre[...]