A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Bard GVDM-26, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bard GVDM-26 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Bard GVDM-26. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Bard GVDM-26 should contain:
- informations concerning technical data of Bard GVDM-26
- name of the manufacturer and a year of construction of the Bard GVDM-26 item
- rules of operation, control and maintenance of the Bard GVDM-26 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bard GVDM-26 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bard GVDM-26, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bard service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bard GVDM-26.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Bard GVDM-26 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Manual 2100-517 Page 1 of 1 1 GVDM-26 DOMESTIC HOT WA TER DESUPERHEA TER PUMP MODULE KIT Manual No.: 2100-517 Supersedes: NEW File: V olume I, T ab 9 Date: 02-06-09 Bard Manufacturing Company , Inc. Bryan, Ohio 43506 Since 1914...Moving ahead just as planned. © Copyright 2009 INST ALLA TION INSTRUCTIONS[...]
-
Page 2
Manual 2100-517 Page 2 of 1 1 CONTENTS General ................................................................. 3 Descriptio n ............................................................ 3 Location ................................................................. 3 Electrical Connection ............................................. 3 Soldering T [...]
-
Page 3
Manual 2100-517 Page 3 of 1 1 GENERAL The pump module kit should only be installed by trained technicians. These instructions serve as a guide to the technician installing the pump module kit. They are not intended as a step-by-step procedure with which the mechanically inclined owner can install the unit. DESCRIPTION The system is designed to heat[...]
-
Page 4
Manual 2100-517 Page 4 of 1 1 OPERATION OF THE HEAT RECOVERY UNIT The pump module is a very simple device containing basic controls and a circulating pump. Heat is transferred from the hot refrigerant (discharge gas) to the cool water. The operation of the Desuperheater Pump Module is controlled first by the operation of the Geothermal Heat Pump an[...]
-
Page 5
Manual 2100-517 Page 5 of 1 1 NC LINE VOLTAGE WATER SENSORS TSTAT 3 AMP FUSE POWER PUMP OUTLET NL OV ER TEMP . LIMIT OUTLET INLET Y RC 24VAC L N CONTROL LOGIC NO C BLUE BLUE THER MIST OR BLUE BLUE THER MIST OR GREEN PUMP 4053-113 LOW VO LTAG E WIRING PUMP CONTROL HIGH VOLTAGE WALL P LUG RED FAC TORY DESUPERHEAT ER TEM PERATU RE MOTOR 24 VA C LIMIT [...]
-
Page 6
Manual 2100-517 Page 6 of 1 1 SUPPLIED WITH PUMP MODULE SCREWS INLET AND OUTLET TUBES ATTACH TO UNIT USING PROVIDED FILTER ASSEMBLY DESUPERHEATER PUMP MODULE MIS-2647 Figure 1 MOUNTING DIRECTLY ONTO UNIT[...]
-
Page 7
Manual 2100-517 Page 7 of 1 1 MIS -2651 INSULATION. OUT TO DSH COIL INLET HEATER OUTL ET AND WRAP WITH PROVIDED OUTLET THERM ISTOR NOTE: REMOVE DURING TUBE AND WRAP WITH PROVIDED SOLDERING, THEN RE-INSTA LL INSULATION. AIR. SOLDERING, THEN RE-INSTA LL NOTE: PUMP IS NOT SELF-PRIMING , IT I S RECOMMENDED TO MANUALLY BLEED-OFF NOTE: INSTALL ER MUST IN[...]
-
Page 8
Manual 2100-517 Page 8 of 1 1 Figure 3 REMOTE MOUNTING & PIPING[...]
-
Page 9
Manual 2100-517 Page 9 of 1 1 Figure 4 SINGLE TANK SYSTEM[...]
-
Page 10
Manual 2100-517 Page 10 of 1 1 CONTROL BOARD SEQUENCE of OPERATION The desuperheating control board will make a determination whether or not to energize the pump relay inclusive on the control board. A. It will constantly monitor inputs from two temperature sensors, Inlet & Outlet water sensors. B. It will constantly monitor the Y signal. C. Up[...]
-
Page 11
Manual 2100-517 Page 11 of 1 1 7 2 4 3 5 MIS -2669 6 1 Figure 6 REPLACEMENT PARTS . o N g n i w a r D. o N t r a Pn o i t p i r c s e D 14 - 4 7 3 - 7 2 1 Se s a B 21 7 1 - 2 0 4 8t i m i L e r u t a r e p m e T r e t a W 31 7 3 - 3 1 1t e k c a r B d r a o B l o r t n o C 44 1 1 - 1 0 2 8d r a o B l o r t n o C r e t a e h r e p u s e D 55 4 0 - 4[...]