Go to page of
Similar user manuals
-
Air Conditioner
Bard W60L2
11 pages 0.45 mb -
Air Conditioner
Bard W30A1
25 pages 0.34 mb -
Air Conditioner
Bard Q36A1
38 pages 0.93 mb -
Air Conditioner
Bard W24A to W70A
8 pages 0.22 mb -
Air Conditioner
Bard WA381
21 pages 0.32 mb -
Air Conditioner
Bard 357-93-E
12 pages 0.36 mb -
Air Conditioner
Bard W42L
25 pages 0.48 mb -
Air Conditioner
Bard R-410A
16 pages 0.74 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Bard P1148A1, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bard P1148A1 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Bard P1148A1. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Bard P1148A1 should contain:
- informations concerning technical data of Bard P1148A1
- name of the manufacturer and a year of construction of the Bard P1148A1 item
- rules of operation, control and maintenance of the Bard P1148A1 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bard P1148A1 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bard P1148A1, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bard service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bard P1148A1.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Bard P1148A1 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
SINGLE P ACKAGE AIR CONDITIONERS MODELS P1 142A3 P1 148A1 P1060A1 INST ALLA TION INSTRUCTIONS Manual : 2100-324B Supersedes: 2100-324A File: V olume II T ab 10 Date: 04-01-02 Bard Manufacturing Company Bryan, Ohio 43506 Since 1914 . . . Moving ahead, just as planned © Copyright 2002[...]
-
Page 2
Contents Getting Other Informations and Publications ........ 1 General Instructions Important ................................................................ 4 Shipping Damage .................................................... 4 General ................................................................ 4 Field-Installed Heater Packages (Optional)[...]
-
Page 3
Manual 2100-324 Page 1 Getting Other Information and Publications These publications can help you install the air conditioner or heat pump. You can usually find these at your local library or purchase them directly from the publisher. Be sure to consult current edition of each standard. National Electrical Code ........................... ANSI/NFPA[...]
-
Page 4
Manual 2100-324 Page 2 l e d o M d e t a R & s t l o V s e s a h P g n i t a r e p O e g a t l o V e g n a R m u m i x a M s p m A t i n U m u m i x a M l a n r e t x E r o s e s u F . k r B . t k C m u m i n i M t i u c r i C y t i c a p m A d l e i F r e w o P g n i r i W d n u o r G e z i S e r i W A . t k CA . t k CA . t k CA . t k C 3 A 2 [...]
-
Page 5
Manual 2100-324 Page 3 r e t a e H l e d o M . g k P . o N s t l o V t i n U e s a h P & W K . r t H y t i c a p a C @ r o ( V 0 4 2 f i V 0 8 4 ) e l b a c i l p p a & W K . r t H y t i c a p a C @ s t l o V 8 0 2 @ V 0 4 2 s a V 0 8 4 r o e l b a c i l p p a s p m A . r t H r e t a e H l a n r e t n I s e s u F B t i u c r i C . o N d l e[...]
-
Page 6
Manual 2100-324 Page 4 GENERAL INSTRUCTIONS IMPORTANT The equipment covered in this manual is to be installed by trained, experienced service and installation technicians. All duct work, supply and return ducts, must be properly sized for the design air flow requirement of the equipment. ACCA is an excellent guide to proper sizing. All duct work or[...]
-
Page 7
Manual 2100-324 Page 5 FIGURE 1 PREFABRICATED ROOF CURB SPECIFICATIONS HEAVY GAUGE GALVANIZED WITH WOOD NAILING STRIP, WELDED/LEAKPROOF ONE PIECE CONSTRUCTION – READY TO INSTALL MIS-1177 FIGURE 2 FIELD FABRICATED CURBING MIS-1178 CURB AND ROOF DET AILS * Duct Sizing Information Return Air Dimension “ C ” is length Supply Air Dimension “ C ?[...]
-
Page 8
Manual 2100-324 Page 6 INST ALLA TION LOCATION GENERAL The unit must be located outside, or in a well ventilated area. It must not be in the space being heated or cooled. A sound absorbing material should be considered if the unit is to be installed in such a position or location that might cause transmission of sound or vibration to the living are[...]
-
Page 9
Manual 2100-324 Page 7 FIGURE 3 ELEVATED MOUNTING PLATFORMS MIS-1183 MIS-1185 FIGURE 4 AIRFLOW AND SERVICE ACCESS CLEARANCES[...]
-
Page 10
Manual 2100-324 Page 8 FIGURE 5 ROOF TOP APPLICATION (MAY ALSO BE REQUIRED FOR GROUND LEVEL INSTALLATIONS.) MIS-1176 FIGURE 6 SLAB MOUNTING AT GROUND LEVEL (ABOVE 32° F OUTSIDE TEMPERATURE) MIS-1184[...]
-
Page 11
Manual 2100-324 Page 9 FIGURE 7 CONDENSATE DRAIN TRAP MIS-136 3. SLAB MOUNTED AT GROUND LEVEL – This type installation is ideal for homes with a slab floor construction where a roof mounted unit is not desired. The supply and return duct work can be run through a furred closet space. 4. THROUGH THE WALL – This type installation requires a suita[...]
-
Page 12
Manual 2100-324 Page 10 TABLE 7 THERMOSTAT WIRE SIZE A V r e m r o f s n a r TA L Fe g u a G e r i W m u m i x a M e c n a t s i D t e e F n I 5 53 . 2 0 2 8 1 6 1 4 1 2 1 5 4 0 6 0 0 1 0 6 1 0 5 2 TABLE 8 WALL THERMOSTAT AND SUBBASE COMBINATIONS t a t s o m r e h Te s a b b u Ss e r u t a e F e t a n i m o d e r P 2 0 0 - 3 0 4 8 1 1 1 3 F 7 8 T 3[...]
-
Page 13
Manual 2100-324 Page 11 FIGURE 8 LOW VOLTAGE WIRING MIS-1180[...]
-
Page 14
Manual 2100-324 Page 12 ST ART UP AND OPERA TION THREE PHASE SCROLL COMPRESSOR START UP INFORMATION Scroll compressors, like several other types of compressors, will only compress in one rotational direction. Direction of rotation is not an issue with single phase compressors since they will always start and run in the proper direction. However, th[...]
-
Page 15
Manual 2100-324 Page 13 ALARM OUTPUT Alarm terminal is output connection for applications where alarm signal is desired. This terminal is powered whenever compressor is locked out due to HPC or LPC sequences as described. NOTE: Both high and low pressure switch controls are inherently automatic reset devices. The high pressure switch and low pressu[...]
-
Page 16
Manual 2100-324 Page 14 FAN BLADE SETTINGS Shown in Figure 9 are the correct fan blade setting dimensions for proper air delivery across the outdoor coil. Any service work requiring removal or adjustment in the fan and/or motor area will require that the dimensions below be checked and blade adjusted in or out on the motor shaft accordingly. FIGURE[...]
-
Page 17
Manual 2100-324 Page 15 TABLE 10 PRESSURE TABLE COOLING Air T emperature Entering Outdoor Coil Degrees F l e d o M r i A n r u t e R e r u t a r e p m e T e r u s s e r P 5 70 85 80 95 90 0 15 0 10 1 15 1 1 3 A 2 4 1 1 P B D . g e d 5 7 B W . g e d 2 6 e d i S w o L e d i S h g i H 0 7 8 0 2 2 7 3 2 2 5 7 9 3 2 7 7 4 5 2 8 7 1 7 2 9 7 8 8 2 0 8 5 0[...]
-
Page 18
Manual 2100-324 Page 16[...]
-
Page 19
Manual 2100-324 Page 17[...]
-
Page 20
Manual 2100-324 Page 18[...]
-
Page 21
Manual 2100-324 Page 19[...]
-
Page 22
Manual 2100-324 Page 20[...]
-
Page 23
Manual 2100-324 Page 21[...]