Go to page of
Similar user manuals
-
Heat Pump
Bard GVDM-26
7 pages 0.04 mb -
Heat Pump
Bard W36H1
27 pages 0.34 mb -
Heat Pump
Bard Q42H1
42 pages 1.01 mb -
Heat Pump
Bard I30H1
59 pages 1.91 mb -
Heat Pump
Bard S**H
19 pages 0.29 mb -
Heat Pump
Bard WH483
23 pages 0.29 mb -
Heat Pump
Bard I48H1D
59 pages 1.91 mb -
Heat Pump
Bard 2100-073
66 pages 1.27 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Bard S**H*D, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bard S**H*D one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Bard S**H*D. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Bard S**H*D should contain:
- informations concerning technical data of Bard S**H*D
- name of the manufacturer and a year of construction of the Bard S**H*D item
- rules of operation, control and maintenance of the Bard S**H*D item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bard S**H*D alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bard S**H*D, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bard service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bard S**H*D.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Bard S**H*D item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Manual 2100-516H Page 1 of 19 INST ALLA TION INSTRUCTIONS SINGLE ST AGE HEA T PUMPS LOW VOL T AGE CONTROL CIRCUIT WIRING MODELS W**H W**H*D S**H S**H*D T**H T**H*D Manual : 2100-516H Supersedes: 2100-516G File: V olume III T ab 16 Date: 03-28-14 Bard Manufacturing Company , Inc. Bryan, Ohio 43506 Since 1914...Moving ahead just as planned.[...]
-
Page 2
Manual 2100-516H Page 2 of 19 Contents Figures Figure 1 Basic HP w/Opt. Elec. Heat ..................... 5 Figure 2 HP w/Opt. MF AD, CRV & ERV V ent. Pkg. w/Programmable T -Stat ........................... 6 Fi gu re 3 HP w/Opt. MF AD, CRV & ERV V ent. Pkg. w/Non-Programmable T -Stat .................... 7 Figure 4 HP w/Opt. MF AD, CRV &[...]
-
Page 3
Manual 2100-516H Page 3 of 19 T ABLE 1 DIAGRAM TO USE WITH UNIT AND VENTS System V ent None CRV , ERV , MF AD CRVMWH-3 CHCRV -5 EIFM Economizer ECONWM* CS2000A* V ent Code X R, M, V , P C E T , W , S Thermostat Programmable Programmable Programmable Programmable Programmable All Model Series No Ye s No Ye s No Ye s No Ye s No Ye s Heat Pump S**H T*[...]
-
Page 4
Manual 2100-516H Page 4 of 19 Part Number Predominate Features 8403-038 (H600A1014) SPDT switching, pilot duty 50V A @ 24V Humidity range 20-80% RH 8403-047 (H200-10-21-10) Electronic dehumidistat SPST closes-on-rise Humidity range 10-90% with adjustable stops Part Number Predominate Features 8403-067 Normally Open SPST relay closes-on-rise 24V dua[...]
-
Page 5
Manual 2100-516H Page 5 of 19 FIGURE 1 BASIC HEA T PUMP WITH OPTIONAL ELECTRIC HEA T NO ECONOMIZER or VENTILA TION P ACKAGES C Facto ry Jumper I nstalled 1 Un it 1 24V Low Voltage Terminal Blo ck W3 E L DH O1 W2 W1 Y1 B Y R G MI S- 2645 C Aux Low V oltage Wi ring Diagram C G R Rc Y O /B 1 L E W1 /E C Bard par t #8403-058 #TH5220D1151 Thermostat 2 S[...]
-
Page 6
Manual 2100-516H Page 6 of 19 FIGURE 2 HEA T PUMP WITH OPTIONAL MF AD, CRV & ERV VENTILA TION P ACKAGING WITH PROGRAMMABLE THERMOST A T (RECOMMENDED) 1 6 5 2 4 3 3 4 if optional CO controller is used. Unit C G R Y E Y1 W2 W1 O1 DH L B W3 Terminal Block 24V Low Voltage Ventilation Packaging with Progra mm able Therm ostat (Reco mm ended) Figure [...]
-
Page 7
Manual 2100-516H Page 7 of 19 FIGURE 3 HEA T PUMP WITH OPTIONAL MF AD, CRV and ERV VENTILA TION P ACKAGING WITH NON-PROGRAMMABLE THERMOST A T (NO OCCUPIED SIGNAL) E Un it C R Y E Y1 Low Vol tage Wi ri ng Diagram W1 O1 Bl ack L B when DH Bard par t #8403-058 W3 24V Low V oltage Therm ostat #TH5220D 1151 R Red Fact ory Jumper I nst al l ed G ERV Oran[...]
-
Page 8
Manual 2100-516H Page 8 of 19 FIGURE 4 HEA T PUMP WITH OPTIONAL MF AD, CRV and ERV VENTILA TION P ACKAGING WITH NON-PROGRAMMABLE THERMOST A T WITH CO2 CONTROLLER Un it C G R Y E Y1 W2 W1 O1 DH L B W3 1 Fact ory Jumper I nst al l ed Low Vol tage Wi ri ng Diagram C O/B Y R L AUX Term i nal Bl ock E 24V Low V oltage Bard par t #8403-058 MFAD Bard part[...]
-
Page 9
Manual 2100-516H Page 9 of 19 FIGURE 5 HEA T PUMP WITH OPTIONAL EIFM ECONOMIZER “E” VENT OPTION Un it CRB Y E Y1 W2 W1 O1 DH Terminal Blo ck L W3 G Y2 Y1 Pi nk Thermostat Or ange Ye ll ow C Black 24V Low Voltage L Pu rp le YO/D Y1 1 Facto ry Jumper I nstalled. 2 be active as fi rs t stage cooling. Must be configured f or economizer with YO/D ou[...]
-
Page 10
Manual 2100-516H Page 10 of 19 FIGURE 6 HEA T PUMP WITH DEHUMIDIFICA TION SEQUENCE AND NO VENTILA TION P ACKAGE USING THERMOST A T #8403-060 COMBINA TION TEMPERA TURE & HUMIDITY CONTROLLER C Facto ry Jumper I nstalled. Un it A G O1 RE Y1 W2 Y2 D HL W1 Electron ic B YO/D Terminal Blo ck Fi gu re 6 Low V oltage Wi ring Diagram C O /B R G L 24V Lo[...]
-
Page 11
Manual 2100-516H Page 1 1 of 19 FIGURE 7 HEA T PUMP WITH DEHUMIDIFICA TION SEQUENCE WITH NON-PROGRAMMABLE THERMOST A T C Un it C G R Y E Y1 Bard par t #8403-038 E O1 DH L B Term i nal Bl ock #TH5220D 1151 W3 24V Low V olt age 1 Mechani cal Humi di stat L W1 Red Yel low 6 5 3 4 1 Fact ory Jumper I nst al l ed. Jumper needs t o be added. Bard par t #[...]
-
Page 12
Manual 2100-516H Page 12 of 19 FIGURE 8 HEA T PUMP WITH DEHUMIDIFICA TION SEQUENCE & OPTIONAL MF AD, CRV & ER V VENTILA TION P ACKAGING USING ELECTRONIC THERMOST A T WITH COMBINA TION TEMPERA TURE & HUMIDITY CONTROL WITH OPTIONAL CO2 CONTROLLER 2 G Block Red during scheduled occupied periods. Figure 8 C C Unit Low Voltage Wiring Diagram[...]
-
Page 13
Manual 2100-516H Page 13 of 19 FIGURE 9 HEA T PUMP WITH DEHUMIDIFICA TION SEQUENCE & OPTIONAL MF AD, CRV & ERV VENTILA TION P ACKAGING USING A NON-PROGRAMMABLE THERMOST A T (NO OCCUPIED SIGNAL) Term i nal Bl ock El ectroni c Humi di stat Low Vol tage Wi ri ng Di agram G O/B Y R Y1 AUX L Bard par t #8403-047 2 24V Low V olt age Bard par t #8[...]
-
Page 14
Manual 2100-516H Page 14 of 19 FIGURE 10 HEA T PUMP WITH DEHUMIDIFICA TION SEQUENCE & OPTIONAL MF AD, CRV & ERV VENTILA TION P ACKAGING USING A NON-PROGRAMMABLE THERMOST A T WITH CO2 CONTROLLER 2 Cool Un it 24V Low V oltage Low Vol tage Wi ri ng Di agram Term i nal Bl ock Heat 2 St age Y1 1 Bard par t #8403-058 Jumper needs t o be added. #T[...]
-
Page 15
Manual 2100-516H Page 15 of 19 FIGURE 1 1 HEA T PUMP WITH CS2000A2 JUMPER IS FACTORY INSTALLED. LIGHTING CONTROL CIRCUIT IS OPTIONAL AND FIELD SUPPLIED. LIGHTING CONTROL RELAY REQUIRES NORMALLY CLOSED CONTACTS AND MUST BE SIZED ACCORDING TO CONTROLLED LOAD. 2 1 CONTROLLER BARD P/N 8403-060 90 SEARCH-TIME 84 LIGHTS TEMPERATURE SWITCHES LEARN FUNCTIO[...]
-
Page 16
Manual 2100-516H Page 16 of 19 FIGURE 12 W**H1 DEHUM. WITH ECONOMIZER & #8403-060 THERMOST A T (EIFM) “E” VENT OPTION *EL ECTRI CAL S H OCK HAZA RD *D ISCO NN E CT POWE R BE FO RE S ERV ICIN G. DAN G ER ! 1 24 56 3 1 24 56 3 Yellow Lo w Volta ge Blue W3 Bla ck *T he r mo stat Mode l C on fi gu rati on Note s: W ** H 1 D e hu m . w i t h E c[...]
-
Page 17
Manual 2100-516H Page 17 of 19 FIGURE 13 1-ST AGE HEA T PUMP WITH OPTIONAL ELECTRIC HEA T WITH OR WITHOUT DEHUMIDIFICA TION WITH ECONWM STYLE ECONOMIZER “W” OR “T” VENT OPTION W1 /E Y2 1 is 10V (100 %) . Depending upon application may require se tt ing t o lower value. YO/D CRB Y E Must be configured f or heat pump / multistage/ no econ[...]
-
Page 18
Manual 2100-516H Page 18 of 19 FIGURE 14 HEA T PUMP WITH OPTIONAL CR VMWH-3 OR CHCRV -5 VENTILA TION P ACKAGING WITH PROGRAMMABLE THERMOST A T (RECOMMENDED) 3 6 5 2 4 1 3 during scheduled occupied periods set to programmed for the "A" output to function Bard part #8403- 067 Factory Jumper Installed Unit C G R Y E Y1 W2 W1 O1 DH L B W3 Ter[...]
-
Page 19
Manual 2100-516H Page 19 of 19 FIGURE 15 HEA T PUMP WITH OPTIONAL CR VMWH-3 OR CHCRV -5 VENTILA TION P ACKAGING WITH NON-PROGRAMMABLE THERMOST A T (NO OCCUPIED SIGNAL) Y L 1 Stage Cool 2 Stage Heat Thermostat #TH5220D1151 Bard part #8403-058 AUX G R Rc O/B C Low Voltage Wiring Diagram E 1 Unit C Factory Jum per Instal led G 2 R E Y1 W2 W1 O1 DH L B[...]