Go to page of
Similar user manuals
-
Air Conditioner
Bard W70L2
11 pages 0.45 mb -
Air Conditioner
Bard WA484
21 pages 0.32 mb -
Air Conditioner
Bard PA13421-A
23 pages 0.57 mb -
Air Conditioner
Bard W42A1
25 pages 0.34 mb -
Air Conditioner
Bard P1230A1
26 pages 0.27 mb -
Air Conditioner
Bard W24L2
8 pages 0.38 mb -
Air Conditioner
Bard WA381
21 pages 0.32 mb -
Air Conditioner
Bard PA13481-B
23 pages 0.57 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Bard WA5S, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bard WA5S one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Bard WA5S. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Bard WA5S should contain:
- informations concerning technical data of Bard WA5S
- name of the manufacturer and a year of construction of the Bard WA5S item
- rules of operation, control and maintenance of the Bard WA5S item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bard WA5S alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bard WA5S, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bard service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bard WA5S.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Bard WA5S item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Form No. S3378-1 1 12 Supersedes S3378-712 Page 1 of 12 Multi-Capacity Two-Stage: Simple thermostatic control seamlessly stages the compressor and indoor airflow rate between high and low capacity operations without cycling the compressor. This helps to maximize comfort, humidity control, energy efficiency and overall reduction in compressor cyclin[...]
-
Page 2
Form No. S3378-1 1 12 Supersedes S3378-712 Page 2 of 12 1 Certified in accordance with ANSI/ARI S tandard 390-2003 for single package vertical unit s. 2 EER = Energy Efficiency Ratio - BTU/W A TT efficiency . 3 Integrated Part Load V alue - BTU/WA TT efficiency and certified in accordance with ANSI/ARI S tandard 390-2003. All capacity , efficiency [...]
-
Page 3
Form No. S3378-1 1 12 Supersedes S3378-712 Page 3 of 12 Bard Wall-Mounts are designed to provide optional ventilation packages to meet all of your ventilation and indoor air quality r equirements. All units are equipped with a blank off plate as the standard ventilation package. All ventilation packages can be built-in at the factory, or field- ins[...]
-
Page 4
Form No. S3378-1 1 12 Supersedes S3378-712 Page 4 of 12 CRVMP-5 W A3S/WL3S V entilation Airflow CRVMP-5 W A5S/WL5S V entilation Airflow CRVMP-5 W A4S/WL4S V entilation Airflow 0 100 200 300 400 500 600 700 800 0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 Vent Position Ventilation Airflow (CFM) Stage #2 Operation Blower Only & Stage #1 Operati[...]
-
Page 5
Form No. S3378-1 1 12 Supersedes S3378-712 Page 5 of 12 E C N A M R O F R E P G N I L O O C R E M M U S ) B W ° 2 6 / B D ° 5 7 S N O I T I D N O C N G I S E D R O O D N I ( t n e i b m A . D . O M F C 0 5 4 E T A R N O I T A L I T N E V M F C 5 7 3 E T A R N O I T A L I T N E V M F C 0 0 3 E T A R N O I T A L I T N E V / B D B W F T L V S L V L [...]
-
Page 6
Form No. S3378-1 1 12 Supersedes S3378-712 Page 6 of 12 l e d o M d e t a R s t l o V e s a h P d n a d l e i F . o N r e w o P s t i u c r i C t i u c r i C e l g n i S t i u c r i C e l p i t l u M 3 m u m i n i M t i u c r i C y t i c a p m A 1 m u m i x a M e s u F l a n r e t x E . r k r B . t k C r o 2 d l e i F r e w o P e z i S e r i W 2 d [...]
-
Page 7
Form No. S3378-1 1 12 Supersedes S3378-712 Page 7 of 12 Heater Packages - Field Installed W A3, W A4 & W A5S Heater Packages - Field Installed WL3, WL4 & WL5S s t i n U W K 0 o t t a e H c i r t c e l E g n i d d a r o f d e n g i s e D • s l e d o M V 8 0 2 / 0 3 2 n o d r a d n a t S r e k a e r B t i u c r i C • d e t s i L a d a n a[...]
-
Page 8
Form No. S3378-1 1 12 Supersedes S3378-712 Page 8 of 12 76" 42 3/8" 34 1/4" 12 1/8" 20 1/4" MIS-2208 A MIS-2164 9 7/8" 6" 50 3/4" 12" 44" 29 7/8" 5" 12" DIA. HOLES FOR DUCT COLLARS. DUCT COLLARS FIELD SUPPLIED. 14" 14" Return Air Acoustical Plenum W APR1 1 W APS51-G Supply A[...]
-
Page 9
Form No. S3378-1 1 12 Supersedes S3378-712 Page 9 of 12 T ypical Sound Performance with Installation/Isolation Curbs & Acoustical Plenums W A/L 3 S S o un d Da t a M a tr i x ( dB A @ 1 0 f e et ) Unit Mounting Direct W MICF-5 Isolation Curb Direct Direct W MICF-5 Isolation Curb W MICF-5 Isolation Curb Supply Air Treatment Grille W APFB51 Free [...]
-
Page 10
Form No. S3378-1 1 12 Supersedes S3378-712 Page 10 of 12 s s e c c A e c i v r e S r o f d e r i u q e R s e c n a r a e l C e k a t n I w o l f r i A r e s n e d n o C e t a u q e d A d n a S L E D O M E D I S T F E L E D I S T H G I R S 5 L / A W , S 4 L / A W , S 3 L / A W" 0 2" 0 2 o t d e r i u q e R s e c n a r a e l C m u m i n i M[...]
-
Page 11
Form No. S3378-1 1 12 Supersedes S3378-712 Page 11 of 12 All dimensions are in inches. Dimensional drawings are not to scale. ) l a n i m o N ( s t n e m e r i u q e R n o i t a l l a t s n I d n a l a r u t c e t i h c r A r o f t i n U c i s a B f o s n o i s n e m i D L E D O M H T D I W ) W ( H T P E D ) D ( T H G I E H ) H ( Y L P P U S N R U [...]
-
Page 12
Form No. S3378-1 1 12 Supersedes S3378-712 Page 12 of 12 Bard Manufacturing Company, Inc. Bryan, Ohio 43506 www.bardhvac.com Due to our continuous product improvement policy, all specifications subject to change without notice. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. s l [...]