Bard WGEIFM-5C manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Bard WGEIFM-5C, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bard WGEIFM-5C one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Bard WGEIFM-5C. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Bard WGEIFM-5C should contain:
- informations concerning technical data of Bard WGEIFM-5C
- name of the manufacturer and a year of construction of the Bard WGEIFM-5C item
- rules of operation, control and maintenance of the Bard WGEIFM-5C item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bard WGEIFM-5C alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bard WGEIFM-5C, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bard service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bard WGEIFM-5C.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Bard WGEIFM-5C item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Manual 2100-498B Page 1 of 17 ECONOMIZER WITH EXHAUST MODEL WGEIFM-3C WGEIFM-5C WGSEIFM-5 For Use with Bard 3 - 5 T on S tep Cap acity and 2 - 5 T on Single S t age W all Mount Air Conditioners with Gas Heat INST ALLA TION INSTRUCTIONS © Copyright 2007 Manual : 2100-498B Supersedes: 2100-498A File: V olume III T ab 19 Date: 02-24-10 Bard Manufactu[...]

  • Page 2

    Manual 2100-498B Page 2 of 17 CONTENTS General General Information ................................................. 3 Unpacking ................................................................ 3 Description ............................................................... 3 Models ................................................................ 3 In[...]

  • Page 3

    Manual 2100-498B Page 3 of 17 GENERAL GENERAL INFORMATION The ventilator should only be installed by a trained heating and air conditioning technician. These instructions serve as a guide to the technician installing the ventilator package. They are not intended as a step by step procedure with which the mechanically inclined owner can install the [...]

  • Page 4

    Manual 2100-498B Page 4 of 17 INST ALLA TION BASIC INSTALLATION 1. Unpack the ventilator assembly which includes the integral ventilator with attached electrical harness, blank-off plate and miscellaneous hardware. 2. Remove and save the existing exterior blower access and service access panels (see Figure 1). 3. Remove and discard exhaust cover pl[...]

  • Page 5

    Manual 2100-498B Page 5 of 17 FIGURE 2 INSTALLATION OF ECONOMIZER FIGURE 2 INSET SIDE SECTION 5. Install ventilator sheet metal assembly by inserting the ventilator into the unit – centering between the tubing on the left and the control panel on the right. Once the ventilator is fully inserted, slide the ventilator to align screw hole through th[...]

  • Page 6

    Manual 2100-498B Page 6 of 17 FIGURE 3 INSTALL LOOSE PIECE WIRE HARNESS PLUG SECURE INTO FILTER TR AY PLUG TO ROUTE WIRES THROUGH WIRE MO UNT, AND INTO HOLE AT REAR O F UNIT INTO L OW VO LTAGE TERMINAL BLOCK AREA MIS -2415[...]

  • Page 7

    Manual 2100-498B Page 7 of 17 9. Mount mixed air thermistor sensor to blower as shown with screws provided. Route two (2) red wires from wire harness installed in Step #7 through cable holders, and connect to thermistor sensor as shown in Figure 2. 10 . Connect the wires (with fork connectors) routed into the low voltage box in Step #7 to the low v[...]

  • Page 8

    Manual 2100-498B Page 8 of 17 EXAMPLE: 1. Measure return air temperature (RAT) (assume 75° F for example). 2. Measure outdoor air temperature (OAT) (assume 60° F for example). 3. Calculate the mixed air temperature (MAT) which will result from the desired combination of OAT (10 percent) and RAT (90 percent). .1 OAT + .9 RAT = MAT or substituting [...]

  • Page 9

    Manual 2100-498B Page 9 of 17 FIGURE 5 ECONOMIZER LOGIC MODULE[...]

  • Page 10

    Manual 2100-498B Page 10 of 17 WG3S Ventilation Airflow 0 100 200 300 400 500 600 700 0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 Vent Pos ition Ventilation Airflow (CFM) Stage #2 Operat ion Blower Only & Stage #1 Operat ion WG4S Ventila tion Airflow 0 100 200 300 400 500 600 700 800 900 0 2.5 5 7.5 10 12.5 15 17.5 20 22 .5 25 27.5 30 Vent P[...]

  • Page 11

    Manual 2100-498B Page 11 of 17 WG5S Ventilation A irflow 0 100 200 300 400 500 600 700 800 900 1000 0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27. 5 30 Vent Position Ventilation Airflow (CFM) Stage #2 Operation Stage #1 Operation Blower Only[...]

  • Page 12

    Manual 2100-498B Page 12 of 17 0 50 100 150 200 250 300 350 400 450 500 550 600 clo sed A B C D Open Damp e r P osit io n W24G EIF M Airflow V ers us Position - Low Spe ed Fr ee Bl ow . 15" ES P . 30" ES P 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 clo sed A B C D Open Damp e r P osit io n W24 G E I FM A irf low V er sus Pos[...]

  • Page 13

    Manual 2100-498B Page 13 of 17 0 50 100 150 200 250 300 350 400 450 500 550 600 650 clo sed A B C D Open Damp e r P osit io n W30- 36G E I FM A ir flow V ers us Position - Low Speed Fr ee Bl ow . 15" ES P . 30" ES P 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 clo sed A B C D Open Damp e r P osit io n W3 0 - 36 G EI FM Air[...]

  • Page 14

    Manual 2100-498B Page 14 of 17 0 50 100 150 200 250 300 350 400 450 500 550 600 650 clo sed A B C D Open Dampe r Po sition W4 2 - 60 G EIF M Airflow V e rsus Po sit ion - Low S pe ed Fr ee Bl ow 0. 15" ES P 0. 30" ES P 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 clo sed A B C D Open Damp e r P osit io n W42 -6 0G EIFM[...]

  • Page 15

    Manual 2100-498B Page 15 of 17 FIGURE 6 ECONOMIZER OPERATION FOR SINGLE COMPRESSOR UNIT[...]

  • Page 16

    Manual 2100-498B Page 16 of 17 FIGURE 7 CALL FOR BLOWER OPERATION ECONOMIZER SEQUENCE OF OPERATION CONDITION A — COOL OUTDOORS First stage cooling closes and powers the economizer dampers to economizer mode and the indoor blower starts. Mixed Air Sensor senses a mixture of return air and outdoor air and modulates the dampers accordingly. Compress[...]

  • Page 17

    Manual 2100-498B Page 17 of 17 CONDITION B — WARM OUTDOORS First stage cooling cycles the compressor and dampers remain in mechanical cooling mode. FIGURE 8 CALL FOR COOLING OPERATION[...]