Black Box IC107AE-R3 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Black Box IC107AE-R3, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Black Box IC107AE-R3 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Black Box IC107AE-R3. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Black Box IC107AE-R3 should contain:
- informations concerning technical data of Black Box IC107AE-R3
- name of the manufacturer and a year of construction of the Black Box IC107AE-R3 item
- rules of operation, control and maintenance of the Black Box IC107AE-R3 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Black Box IC107AE-R3 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Black Box IC107AE-R3, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Black Box service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Black Box IC107AE-R3.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Black Box IC107AE-R3 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500 ) FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mailing address: Black Box Corporation , 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com • E-mail: info@blackbox.com DECEMBER [...]

  • Page 2

    1 FCC/IC RFI ST A TEMENTS, DECLARA TION OF CONFORMITY FEDERAL COMMUNICA TIONS COMMISSION AND INDUSTR Y CANADA RADIO-FREQUENCY INTERFERENCE ST A TEMENTS This equipment generates, uses, and can radiate radio-frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interf[...]

  • Page 3

    2 RS-232 ↔ RS-422/485 CONVER TER (DA T A ONL Y) NORMAS OFICIALES MEXICANAS (NOM) ELECTRICAL SAFETY ST A TEMENT INSTRUCCIONES DE SEGURIDAD 1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia fu[...]

  • Page 4

    3 NOM ST A TEMENT , TRADEMARKS 12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada. 13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los contactos y receptá[...]

  • Page 5

    4 RS-232 ↔ RS-422/485 CONVER TER (DA T A ONL Y) Contents Chapter Page 1. Specifications ............................................................................................. 5 2. Introduction ............................................................................................... 7 3. Configuration .................................[...]

  • Page 6

    5 CHAPTER 1: Specifications 1. Specifications Compliance: CE; FCC Part 15 Subpart B Class A, IC Class/classe A Interfaces: EIA/TIA RS-232, DTE or DCE (user-selectable); EIA/TIA RS-422/485 Protocol: Asynchronous Data Rate: Transparent to data rates up to 64 kbps Data Format: Transparent to data format Flow Control: Transparent to software flow contr[...]

  • Page 7

    6 RS-232 ↔ RS-422/485 CONVER TER (DA T A ONL Y) Temperature Tolerance: Operating: 32 to 122˚F (0 to 50˚C) Storage: –4 to +158˚F (–20 to +70˚C) Humidity Tolerance: Up to 95% noncondensing MTBF: 200,000 hours Power: IC107A-R3 and IC107AE-R3: From utility-power (mains) outlet, through external power supply with detachable region-specific inp[...]

  • Page 8

    7 CHAPTER 2: Introduction 2. Introduction The RS-232 ↔ RS-422/485 Converter (Data Only) allows your RS-232 and RS-422/485 equipment to communicate with each other. It operates in full-duplex mode over 4-wire lines. A four-wire terminal block on the RS-422/485 port makes installation easy. And this interface converter is flexible: it can work in e[...]

  • Page 9

    8 RS-232 ↔ RS-422/485 CONVER TER (DA T A ONL Y) 3. Configuration Here’s how to configure the RS-232 ↔ RS-422/485 Converter (Data Only) for your application (refer to Figure 3-1 on the next page for the location of components on the circuit board): CAUTION! The Converter’s circuit board can be damaged by static electricity, so take every rea[...]

  • Page 10

    9 CHAPTER 3: Configuration 5. Normally, the Converter’s frame ground is isolated from its RS-232 signal ground. But if you want to connect frame ground to signal ground, you’ll need to solder a 100-ohm, 500-mW resistor to the terminals of location W7. (You could also use a wire jumper, but you’d need to make sure that any ground-loop currents[...]

  • Page 11

    10 RS-232 ↔ RS-422/485 CONVER TER (DA T A ONL Y) 4. Installation To install your RS-232 ↔ RS-422/485 Converter (Data Only) system, take these steps, making sure that the Converter and your devices are powered OFF: 1. Run an RS-232 cable from your RS-232 device to the Converter’s DB25 female RS-232 port. 2. Run a 4-wire cable from your RS-422 [...]

  • Page 12

    11 CHAPTER 5: Operation 5. Operation 5.1 RS-232 Circuitry The RS-232 side of the RS-232 ↔ RS-422/485 Converter (Data Only) is composed of the RS-232 drivers and receivers, the delay circuitry, and other circuitry necessary to operate the RS-232 control lines. Data traveling from the RS-232 interface to the RS-422/485 interface: When the RS-232 po[...]

  • Page 13

    12 RS-232 ↔ RS-422/485 CONVER TER (DA T A ONL Y) Figure 5-1. Block diagram of Converter functions in DCE mode. Figure 5-2. Block diagram of Converter functions in DTE mode. RS-232 side RS-232 side RS-422/485 side RS-422/485 side[...]

  • Page 14

    13 CHAPTER 5: Operation 5.2 RS-422/485 Circuitry The RS-422/485 side of the Converter is made up of the driver, receiver, and line- termination networks. As described in Chapter 3 , you can use switch S2 to either connect the receiver’s termination network to the line (terminate the RS-422/485 port) or leave it unconnected (unterminated). Having [...]

  • Page 15

    14 RS-232 ↔ RS-422/485 CONVER TER (DA T A ONL Y) 6. T roubleshooting 6.1 Calling Black Box If you determine that your RS-232 ↔ RS-422/485 Converter (Data Only) is malfunctioning, do not attempt to alter or repair the unit . It has no user-serviceable components. Contact Black Box Technical Support at 724-746-5500. Before you do, make a record o[...]

  • Page 16

    15 APPENDIX: Pinouts Appendix: Pinouts T able A-1. Pinning of the RS-232 connector (DB25 female). Pin Number and Signal Function Pin1 — Frame Ground Connects the Converter’s frame ground to the frame ground of the RS-232 device. Pin 2 — TD When the Converter is set to DCE, data is received on Pin 2 and the TX LED lights up when Pin 2 is a “[...]

  • Page 17

    16 RS-232 ↔ RS-422/485 CONVER TER (DA T A ONL Y) T able A-2. Pinning of the RS-422/485 connector (4-position ter minal block). Pin/Signal Function TXA and TXB Data received by the Converter from the RS-232 port is transmitted out of the unit over twisted-pair wires using these two outputs. The “TX” LED indicates the state of these two leads. [...]

  • Page 18

    NOTES[...]

  • Page 19

    NOTES[...]

  • Page 20

    1000 Park Drive • Lawrence, PA 15055-1018 • 724-746-5500 • Fax 724-746-0746 © Copyright 2001. Black Box Corporation. All rights reserved.[...]