Go to page of
Similar user manuals
-
Switch
Black Box ACS4201A
38 pages 0.78 mb -
Switch
Black Box MT722A-35T
42 pages 0.2 mb -
Switch
Black Box lgb516a
16 pages 1.38 mb -
Switch
Black Box RS-485
68 pages 32.03 mb -
Switch
Black Box KV1424A-R2
114 pages 5.54 mb -
Switch
Black Box AVSW-VGA8X1A
24 pages 1.44 mb -
Switch
Black Box SW982A
26 pages 0.14 mb -
Switch
Black Box ACU2022A
66 pages 3.64 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Black Box ISU2011-8-EURO, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Black Box ISU2011-8-EURO one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Black Box ISU2011-8-EURO. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Black Box ISU2011-8-EURO should contain:
- informations concerning technical data of Black Box ISU2011-8-EURO
- name of the manufacturer and a year of construction of the Black Box ISU2011-8-EURO item
- rules of operation, control and maintenance of the Black Box ISU2011-8-EURO item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Black Box ISU2011-8-EURO alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Black Box ISU2011-8-EURO, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Black Box service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Black Box ISU2011-8-EURO.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Black Box ISU2011-8-EURO item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
BRI-Hub TECHNICAL: SALES: FAX: ADDRESS: WEB: (0118) 965 6000 (0118) 965 5100 (0118) 965 5001 464 Basingstoke Road, Reading, Berkshire RG2 0QN www.blackbox.co.uk 4-Port BRI -Hub (UK): I SU2011-4-UK 4-Port BRI -Hub (Euro): I SU2011-4-EURO 8-Port BRI -Hub (UK): I SU2011-8-UK 8-Port BRI -Hub (Euro): I SU2011-8-EURO[...]
-
Page 2
2 BRI-Hub SALES: 0118 965 5100 How To Contact your Local Black Box I t a l y : A u s t r a l i a : Black Box Ital ia S.P.A Black Box Catalog A ustrali a PTY LT D Tel: 0227400280 Tel: 0398797100 Fax: 0227400219 Fax: 0398702955 Web Si te: www.b lac kb ox .i t Deutschland: Brazil: Black Box Deu tsch land Black Box Do Br asil. Tel: 0811/ 5541-0 Tel: (0[...]
-
Page 3
3 BRI-Hub TECHNICAL: 0118 931 2233 Contents Introduction ............................................................................................................................... 4 Description of functions ................................................................................................ 4 Options. ..............................[...]
-
Page 4
4 BRI-Hub SALES: 0118 965 5100 Introduction Within the data communications and L AN industry it is well known that a structured cabling concept using a star topology has significant advantages, such easier maintenance, unproblematic changes in the configuration and faster fault finding. L ast but not least, a structured cabling concept may be used [...]
-
Page 5
5 BRI-Hub TECHNICAL: 0118 931 2233 I f a BRI needs to be made available in several rooms, it used to be necessary to install a bus from the server room through all rooms. (See picture ‘old’). Now star wiring can be used with BRI -Hub, which comes to use also for telephone and local area networks (see picture 'with BRI -Hub'). Options [...]
-
Page 6
6 BRI-Hub SALES: 0118 965 5100 Technical Specifications SO Interface BRI Number of interfaces……………………………………5 for BRI -Hub-4, 9 for BRI -Hub -8 Ty pe and coding…………………………………………I.430, Mod. AMI , 4-wire Frame structure………………………………………….I .430 (48 Bits per 250 µ[...]
-
Page 7
7 BRI-Hub TECHNICAL: 0118 931 2233 Environmental and Safety Notes The device conforms to all european and international standards for safety , environment, EMC and the ISDN basic rate interface. Power Supply • The power adaptor is according to safety class II (VDE 0551) and my only be used indoor. • Do not use the power adaptor when it was brou[...]
-
Page 8
8 BRI-Hub SALES: 0118 965 5100 Installation For proper operation the device must be placed in a suitable location. I t should be a clean and dry environment without direct sun light. Sufficient cooling must be possible. Do not pack or cover the unit or set other warm equipment on top of it. Tabletop Just place the unit on a clean and dry place. Mul[...]
-
Page 9
9 BRI-Hub TECHNICAL: 0118 931 2233 • The screws must be put into the holes of the BRI -Hub. The screws slide approx imately 25 mm into the case . • The screws can be screwed in tight. Power Supply BRI-Hub The standard BRI -Hub is supplied with a wall mount power adapter. There is no power switch at the devi ce. The BRI -Hub is active when t he [...]
-
Page 10
10 BRI-Hub SALES: 0118 965 5100 Connecting the Hub 6V DC CE The DC connector of the power adapter i s inserted in to the jack on t he left side of t he rear panel (Jack "6V DC"). Do not use other power adaptors than t he original one. In any case notice t he polarity of the connector. I nner tip +, outer ring -. To connect the BRI -Hub to[...]
-
Page 11
11 BRI-Hub TECHNICAL: 0118 931 2233 The TE -ports termination resi stors are permanently active and cannot be switched off. Please install te rminating r esistors to the end of the connecting cables. I n the above ex ample the Term-switch must be in the off position, i.e. termination resistors are off. This is because the BRI -Hub is not connected [...]
-
Page 12
12 BRI-Hub SALES: 0118 965 5100 Configuration for power fail communication with the BRI -Hub I f cable connections between th e BRI-Hub and the terminal equipment (TE) are l onger than the proposed 150m, operation may be possible under specific conditions: 1. The NT must be switched to "extended passive bus". "Point-to-point" or[...]
-
Page 13
13 BRI-Hub TECHNICAL: 0118 931 2233 Termination Resistors The signal pa irs must be terminate d with 100 Ω resistors at both ends of the bus. These must be in stalled as shown below. If not placed correctly , t hey may short the power feeding voltage. 100 Ω each Pin Pin descripti on Direction 1 2 3 2a TE NT 4 1a NT TE 5 1b NT TE 6 2[...]
-
Page 14
14 BRI-Hub SALES: 0118 965 5100 Operation No service is needed during operation. Cable shorts at one TE port only affect the power feeding voltage of all ports if they are internally connected. To reduce this effect self-healing fuses are connected to each port. The current version of the BRI -Hub cannot clear problems with cable reversals of the T[...]
-
Page 15
15 BRI-Hub TECHNICAL: 0118 931 2233 Troubleshooting Fault Problem How to cl ear the problem Pwr-LED is off BRI -Hub is powered off Plug in power adaptor No mains power Check for main power Faulty power adaptor Use other com patible power adaptor. Check polarity ! For BRI -HUB-S only: loss of power inside NT or PABX Use original power adapter BRI -H[...]
-
Page 16
16 BRI-Hub SALES: 0118 965 5100 Notes[...]