Go to page of
Similar user manuals
-
Network Card
Black Box IC907C
20 pages 0.46 mb -
Network Card
Black Box LMC200A-DC
4 pages 0.1 mb -
Network Card
Black Box STD-C
1 pages 0.12 mb -
Network Card
Black Box 16 port
263 pages 2.97 mb -
Network Card
Black Box FT991
1 pages 0.11 mb -
Network Card
Black Box WP170GR
1 pages 0.34 mb -
Network Card
Black Box G703/V.35
3 pages 0.03 mb -
Network Card
Black Box IC266A
26 pages 0.15 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Black Box MDS933C-10BT, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Black Box MDS933C-10BT one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Black Box MDS933C-10BT. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Black Box MDS933C-10BT should contain:
- informations concerning technical data of Black Box MDS933C-10BT
- name of the manufacturer and a year of construction of the Black Box MDS933C-10BT item
- rules of operation, control and maintenance of the Black Box MDS933C-10BT item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Black Box MDS933C-10BT alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Black Box MDS933C-10BT, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Black Box service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Black Box MDS933C-10BT.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Black Box MDS933C-10BT item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
User Manual MDS932AE-10BT STANDALONE MDS932AE-FXO STANDALONE MDS932AE-FXS STANDALONE MDS933AE-10BT STANDALONE MDS932C-10BT RACK-CARD MDS933C-10BT RACK-CARD G.SHDSL Modem USER MANUAL Version 1.2 Revision 26 January 2004 Document name MDS933AE-v1.2.doc[...]
-
Page 2
[...]
-
Page 3
User Manual VERSION CONTROL .......................................................................................................... 5 1 GENERAL INFORMATION........................................................................................ 6 ORDER INFORMATION ...................................................................................[...]
-
Page 4
User Manual 8.4 Line1 and Line2 Connector ............................................................................. 24 9 DESCRIPTION OF INTERFACE CABLES .............................................................. 25 9.1 Ethernet cable ................................................................................................. 25 9.2 DSL[...]
-
Page 5
User Manual VERSION CONTROL Version Date Major changes to previous version 1.0 31.12.2001 Initial version of the manual corresponding to version 1.2 of the device micro program 1.1 23.10.2003 New function description corresponding to software release V1.6 Corrected Connecter description 9.1 Changed DSL cable to twisted type 10.2 1.2 26.1.2004 Manua[...]
-
Page 6
User Manual 1 GENERAL INFORMA TION • High-speed symmetrical data transmission over one physical copper twisted pair with the 135 Ohm impedance according to ETSI TS 101 135. • ITU-T G.991.2 (G.shdsl) line encoding. • Line rate in the range from 72 Kbit/s to 2320 Kbit/s in 2 wire mode Line rate in the range from 144 Kbit/s to 4624 Kbit/s in 4 w[...]
-
Page 7
User Manual ORDER INFORMA TION MDS932AE-10BT Modem AccessDSL Discovery, G.shdsl, 10/100Ba se-T Bridge, VLAN, Adapter 220 Vac MDS933AE-10BT Modem AccessDSL Discovery, G.shd sl, 1 or 2 pairs, up to 4.6Mbps, 10/100Base-T Bridge, VLAN, Adapter 220 Vac MDS932AE-FXS Modem AccessDSL Discovery, G.shdsl, 10/100Ba se-T Bridge, VLAN, Adapter 220 Vac, with FXS[...]
-
Page 8
User Manual 2 DESCRIPTION OF THE DEVICE 2.1 Exterior design Desktop models The front panel of the device has 3 LEDs: LOCAL informs the user about the status of the local device. The following four statuses are possible «blinking red» informs the user about malfunctioning of the modem’s hardware and software. In this case, the modem is out of or[...]
-
Page 9
User Manual The back panel of the MDS932AE-10BT and MDS933AE-10BT modem has: • The grounding bolt of the modem (option); • The “AC12V” power connector. The connection of the modem to the 220 V power supply is implemented using an external power supply unit; • the “Monitor” connector to control the modem and store statistics; • “PC[...]
-
Page 10
User Manual 2.2 Exterior design rack card models[...]
-
Page 11
User Manual Status(L) informs the user about the status of the local device. The following four statuses are possible «blinking red» informs the user about malfunctioning of the modem’s hardware and software. In this case, the modem is out of order and should be submitted to the service center for being repaired. «red» informs the user about [...]
-
Page 12
User Manual 3 RULES OF SWITCHING 3.1 The standalone delivery set The delivery set includes: • the subscriber access dev ice (a modem) • the power supply source (an AC adapter) • the cables for the line connections 3.2 The rack-card delivery set The delivery set includes: • the subscriber access dev ice (a modul) • the cables for the line [...]
-
Page 13
User Manual To update the information on the screen use the “Enter” key. The following menu will appear on the screen. Input Password: Please enter your programmed password. The unit will be delivered with the default password “admin” After entering the password the following menu will appear. Discovery G.SHDSL Ethernet Monitor V1.7 +------[...]
-
Page 14
User Manual 4 THE COMMAND SYSTEM 4.1 Basic rules After the command is typed, press <enter>. The <Backspace> key is used to edit commands. It is necessary to input item number, for choising menu item, You can use “PageUP”, “PageDown” and “Space” keys , for scrolling list of available value of parameters, The “Esc” key is [...]
-
Page 15
User Manual 4.3 Performance management submenu Upon activation of the performance management submenu the following message will be displayed. Performance Management 1.Loop Status... 4.EtherNet Status... Select item number or ESC to Upper level menu>> 4.3.1 Loop Status submenu Upon activation of the performance management submenu the following[...]
-
Page 16
User Manual 4.3.2 Ethernet Status submenu Upon activation of the performance management submenu the following message will be displayed. Performance Management->EtherNet Status Link:Link down Link Speed:---- Link Duplex:---- Used Entries:0 Tx Packets:0 Rx Packets:0 Fwd Packets:0 Drop Packets:0 Speed:Auto Duplex:Auto MAC Address:00-00-00-00-00-00[...]
-
Page 17
User Manual 4.4.1 DSL Setup In this menu you can setup the DSL link. When you have selected that menu, the following will appear: Configuration Management->DSL Setup 1.[Loop 1 Operation Mode]:Slave 2.[Loop 1 Auto/Fixed]:Fixed 5.[Loop 1 Fixed Connection Speed]:2312K(36N) 6.[Loop 1 Annex]:A/B 7.[Loop 1 Tx Level Adjustment]:0 dB 18.[2W/4W]:2W Selec[...]
-
Page 18
User Manual 4.4.1.4 Fixed Connection Speed (only if Fixed is selected) • In the Fixed Connection Speed menu, you can specify your desired speed in the range of 72 kbps to 2312 kbps for 2wire units and 144 kbp s to 4624 kbps for 4wire models 4.4.1.5 Annex • With the Appendix menu you can choose between A, B, A / B. If you don’t know what Annex[...]
-
Page 19
User Manual 4.4.2 Ethernet Setup submenu Configuration Management->EtherNet Setup 1.[Speed]:Auto 2.[Duplex Mode]:Auto 3.[Disable Mac Filter]:No 4.IP Address>>192.168.5.105 5.Subnet Mask>>255.255.255.0 6.Gateway Address>>192.168.5.1 Select item number or ESC to Upper level menu>> • In the Speed menu, you can setup the Et[...]
-
Page 20
User Manual 5 TECHNICAL SPECIFICA TIONS The main technical specifications of modems of the Black Box family are presented below in the table. Line interface. Standard ETSI 101 135 Number of pairs 1 Line rate 2 wire models 4 wire models 72 – 2312 Kbit/s 144 – 4624 Kbit/s Communication range for cables with the wire diameter of 144 Kbit/s 2320 Kb[...]
-
Page 21
User Manual 6 ST ORAGE CONDITIONS The equipment of the Black Box family while being packed should withstand all means of transport at a temperature in the range form -50 о С to +50 о С and the relative humidity of air up to 100% at 25 о С . The equipment can also withstand air-transport at a low air pressure of 12 kPa (90 Torr) at -50 о С .[...]
-
Page 22
User Manual 7 TERMS TO TRANSPORT The equipment of the Black Box family should be packed and transported by: • motor transport with an enclosed truck body; • enclosed railroad cars; • unpressurized airplanes and helicopters (up to 10000 m at an air pressure of 170 Torr); • river transport (in holds). The equipment of the Black Box family sho[...]
-
Page 23
User Manual 8 CONNECT OR’S DESCRIPTION 8.1 DSL Connector Type: RJ-45, 8 pin Number Signal Assignment 1,2 NC - 3 LB,a Ttp (4W model only) 4 LA,a tip 5 LA,b ring 6 LB,b ring (4W model only) 7,8 NC - RJ-45 1 8 8.2 Monitor Connector Type: Sub-D9, female Number Signal Assignm ent 1 NC - 2 TXD Transmit data 3 RXD Receive data 4 DTR Data terminal ready [...]
-
Page 24
User Manual 8.3 PC and Hub Connectors Type: RJ-45 Number PC assignment HUB assignment 1 Tx+ Rx+ 2 Tx- Rx- 3 Rx+ Tx+ 4 NC NC 5 NC NC 6 Rx- Tx- 7 NC NC 8 NC NC 18 RJ-45 8.4 Line1 and Line2 Connector Type: RJ-11, 4 pin Number Signal Assignment 1 NC - 2 LA,a tip 3 LA,b ring 4 NC - RJ-11 1 4 Version: 1.2 Page. 24 of 25[...]
-
Page 25
User Manual Version: 1.2 Page. 25 of 25 9 DESCRIPTION OF INTERF ACE CABLES 9.1 Ethernet cable Side А Color of wire Side B 1 white/green 1 2 green/white 2 3 white/orange 3 4 blue/white 4 5 white/blue 5 6 orange/white 6 7 white/brown. 7 8 brown/white 8 9.2 DSL cable Side А Color of wire Side B 1 white/green 1 2 green/white 2 3 white/orange 3 4 blue[...]