Go to page of
Similar user manuals
-
Electric Steamer
Blodgett SB-16E
14 pages 0.62 mb -
Electric Steamer
Blodgett SN-3E
17 pages 0.32 mb -
Electric Steamer
Blodgett SB-10E
14 pages 0.62 mb -
Electric Steamer
Blodgett CONVECTION STEAMERS KETTLES BRAISING PANS
12 pages 0.5 mb -
Electric Steamer
Blodgett SN-5E
17 pages 0.32 mb -
Electric Steamer
Blodgett SB-6E
14 pages 0.62 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Blodgett SB-10E, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Blodgett SB-10E one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Blodgett SB-10E. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Blodgett SB-10E should contain:
- informations concerning technical data of Blodgett SB-10E
- name of the manufacturer and a year of construction of the Blodgett SB-10E item
- rules of operation, control and maintenance of the Blodgett SB-10E item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Blodgett SB-10E alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Blodgett SB-10E, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Blodgett service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Blodgett SB-10E.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Blodgett SB-10E item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
1 SB-6E, SB-10E and SB-16E CONVECTION STEAMER ON AN ELECTRIC BOILER BASE INSTALLATION – OPERATION – MAINTENANCE BLODGETT OVEN COMPANY www.blodgett.com 44 Lakeside Avenue, Burlington, Vermont 05 401 USA Telephone (800) 33 1-5842, (802) 860 -3700 Fax: (802) 864-0183 S00047 Rev B (12/04)[...]
-
Page 2
2 IMPORTANT NOTES FOR INSTALLATION AND OPERATION It is recommended that this manual be read thoroughly and that all instructions be followed carefully. This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey a ll safety messages that follow this symbol to avoid possible injury or death. WARNING: Improper [...]
-
Page 3
3 TABLE OF CONTENTS DESCRIPTION PAGE Important Notes ............................................................................................................. 2 1.0 Service Connections .............................................................................................. 4 2.0 Installation Instructions ..................................[...]
-
Page 4
4 1.0 SERVICE CONNECTIONS REAR FLANGED FOOT DE TAIL 7/16" [1 1mm] HOLES ON 2.5 [63] B.C. 2 EQUALL Y SP ACED Ø S 6 [152] 5.75 [146] 8.75 [222] 28 [71 1] 16.75 [425] 23 [584] 55.5 [1410] SB-6E 68.50 [1740] SB-10E 67 [1 702] S B-16 E DIMENSIONS ARE IN INCHES [MM] 0 [0] 3.5 [89] 8.75 [2 22] 16.75 [425] 18 [457] (36" CABINET) 2.75 [70] 2.5 [6[...]
-
Page 5
5 2.0 INSTALLATION INSTRUCTIONS Ideally an exhaust system should be locat ed directly above the appliance to exhaust steam and heat generated by the appliance. 1. Set the unit in place and level using a spirit level. 2. Ascertain that a floor drain (open gap) is convenient to the appliance drain. 3. Mark hole locations on floor through anchoring ho[...]
-
Page 6
6 3.0 OPERATING INSTRUCTIONS BOILER SECTION Electrically powered steam generators are av ailable with standard boiler controls or ASME CSD-1 compliant controls. In addition to the ON/OFF power switch and indicator pilot light on the standard controls, the CSD-1 controls come with four more indicator pilot lights and a “Reset” switch. Follow the[...]
-
Page 7
7 3.0 OPERATING INSTRUCTIONS (Continued) Normal Boiler Operating Cycle Water Fill Cycle On the initial filling of the boiler, units equipped with CSD-1 controls require that the “Reset” switch be pressed to initialize the safety lockout circuit. Once the water in the boiler has reached proper level, the level control will stop the flow of water[...]
-
Page 8
8 3.0 OPERATING INSTRUCTIONS (Continued) High Pressure Condition, CSD-1 Controls A high pressure safety switch is installed on the boiler. Should the pressure exceed the limit of this device, the boiler will be shut down and switch to a state of lockout. The “Pressure” pilot light (red), and the “Standby” pilot (amber), will come on. Should[...]
-
Page 9
9 COOKER SECTION CAUTION: Live steam and accumulated h ot water in the compartment may be released when the door is opened. Start-up procedures for your steamer must be completed once daily prior to operation (see instruction plate or above for boiler start up procedures). With ready pilot light on, preheat steamer compartment for one minute when t[...]
-
Page 10
10 4.0 PERIODIC MAINTENA NCE Never spray water into electric controls. Be sure to flush your boiler water level control daily. Failure to follow this procedure can cause the control to malfunction resulting in serious bo iler damage. The Boiler Water Level Control installed on your boiler requires periodic maintenance. As boiler water circulates in[...]
-
Page 11
11 CLEANING 1. Keep exposed cleanable areas of unit clean at all times. 2. Thoroughly wash oven cavities, door liners, and pan racks at the end of each day or as required with a mild detergent and water to prevent bacterial growth and odours. 3. Remove drain screens from inside compartment drains. Using a plastic bottle brush and mild detergent, cl[...]
-
Page 12
12 ADJUSTMENTS DESCALING BOILER It is recommended that the boiler be checked every 90 to 120 days for scale build up. Regular maintenance should be carried out at this time. 1. With boiler empty, close manual blowdown valve. If appliance is equipped with Automatic Blowdown, turn water supply OFF to appliance. Turn power switch ON. This will energiz[...]
-
Page 13
13 TO CALIBRATE PRESSU RE SWITCHES Pressure switch range is from 1 to 15 psi. Adjust all settings to maximum on high signal adjustment screw. Adjust in the following sequence: - High limit pressure switch. - Override pressure switch. - Operating pressure switch. - Turning screw clockwise to increase, counter clockwise to decrease pressure. - Use re[...]
-
Page 14
14 5.0 TROUBLESHOOTING DOOR LEAKS 1. Check for damage to door gasket. WATER ACCUMULATES IN THE COMP ARTMENT 1. Compartment drain screen clogged. Remove and clean thoroughly and then replace. WATER NOT BEING SUPPLIED TO BOILER 1. Water supply is “OFF”. 2. Defective water fill solenoid. 3. Water level control clogged or defective, unable to opera[...]