Bloomfield 2288EX manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Bloomfield 2288EX, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bloomfield 2288EX one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Bloomfield 2288EX. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Bloomfield 2288EX should contain:
- informations concerning technical data of Bloomfield 2288EX
- name of the manufacturer and a year of construction of the Bloomfield 2288EX item
- rules of operation, control and maintenance of the Bloomfield 2288EX item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bloomfield 2288EX alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bloomfield 2288EX, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bloomfield service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bloomfield 2288EX.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Bloomfield 2288EX item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    BLOO MFIEL D IND USTRIE S 2 ERIK CI RCLE, P .O. Box 280 V e rdi, NV 89439 U.S.A. Customer S ervice (775) 345- 0444 Ext.50 2 fax (775) 345- 0569 www .wellsblo omfield.com OWN E RS MANU AL LX AIRPO T & THERMAL BREWERS MODELS 2280 2282 2286EX 2288EX Includes INSTALLAT ION OPERAT ION USE & CARE SERVICE p/n 75209 Rev. E M657 05 0209 cps 657 Mode[...]

  • Page 2

    All electrical equipment ma nufactured by BLOOMFIELD INDUSTRI ES is w arranted against de fects in m aterials and workmanship for a period of one year from the date of original installation or eighteen (18) months from the date of shipment from our factory, whichever comes first, and is f or the benefit of the original purchaser, except that: a. ai[...]

  • Page 3

    TABLE OF CONTENTS ELECTRICAL SPECIFIC A TIONS* MODEL WATTS VOLTS Hz CIRCUIT REQUIRED W IRE 2280 1800 120 50/60 15 AMP ( NEM A 5-15R ) 2 + ground 2282 1800 120 50/60 15 AMP ( NEM A 5-15R ) 2 + ground Canada 1500 watts DIMENSIONS* * for complete informatio n regard ing spe cifications and dimensions, please consult the GLD (General Layout Data) for t[...]

  • Page 4

    FEATURES & OPERATING CONTROLS 1. Brew Indicator Glows during brew cycle, f lashes in “Brew W ait” 2. Heat Indicator Glows when hea ting ele me nts are ener gized 3. Power Indicator Glows when power is on 5. Brew Switch Press to initiate bre w cycle 6. Cancel Switch Press to terminate brew cycle 7. Power Switch Press to turn bre w er on o r [...]

  • Page 5

    PRECAUTIONS AND GENERAL INFORMATION WARNING: Electric Shock Hazard All servicing requiring access to non-insu lated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can re su lt in electrical shock. WA RNI NG: Injur y Hazard All installation proce[...]

  • Page 6

    INSTALLATION INSTRUCTIONS RE A D THIS CAREFULL Y BEFORE ST A R TING TH E INST A LLA TION REFER TO EXPLODED VIEWS PAGES 16 thru 19 FOR COMPONENT NAMES/NUMBERS 1. Unpack the unit. Inspec t a ll components f or completeness and condition. Ensure that all packing materials have been removed from the unit. 2. (See page 16.) Remove the Top W armer Unit ([...]

  • Page 7

    NOTE: This equipment must be installed to comply with applica- ble f ederal, stat e and loc al codes and ordin a nc es. WARNING ELECTRIC SHOCK HAZARD: Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a plumbing line will provide suc h a ground . Electrical shock will cause death or serious injury. IMPORTANT: Do not a[...]

  • Page 8

    OPERATION To over-ride th e Br ew Wait mode , press and hold the BR EW key for 3 second s when the brewer is in Brew Wait mode (i.e. when brew light is flashing). The brew will proceed immedi ately regardless of water temper ature. Th is feature should onl y be used whe n testing water volume, otherwise the br ew will proceed with the water below t[...]

  • Page 9

    OPERATION WA R N I N G : Burn H azard. This applianc e dispenses very hot liquid. Serious bodily injury from scalding can occ ur from contact wi th dispensed liquids. CAUTION: Burn Hazard To avoid splashing or overflowing hot liqu ids, ALWAYS use an empty airpot or thermal server before starting the brew cycle. Failure to comply can cause serious b[...]

  • Page 10

    CLEANING INSTRUCTIONS CA UTI ON: Burn Hazard Brewing an d serving temperatures of coffee are extremely hot. Hot coffee will cause serious skin burns. CA UTIO N: Electric Shoc k Hazard Do not submerge or i mmerse brewer in wat er. Do not pour o r splash water into o r over air vents, control panel or warmer plates. IMPORTANT: DO NOT use steel wool, [...]

  • Page 11

    A. Adjust Brew Time B. Adjust Brew Temperature C. Adjust Quality Timer D. Adjust Dripout Timer E. Adjust After Hours Timer AB C DE UNDER TOP COVER (IN SECONDS ) BREW TIMER (IN °F) BREW TEMP (IN 5 M I N IN C R ) QUAL ITY TIMER (IN SECO ND S) DRIPOUT TIMER (IN ONE HR INCR) AFTER HOU RS TIM ER WATER LEVEL PROBE TEMP PROBE 20 185 6 OFF 3 60 90 30 70 1[...]

  • Page 12

    SERVICING INSTRUCTIONS — ELECTRICAL FILL SOLEN OID WATER LEVEL PROBE CONTROLLER FIL L BRE W BRE W TIME BREW SOLEN OID DRIP OUT TIME BRE W CANCEL CONTROLLER BREW WA TER TEM P PRO BE BRE W TEMP TRIAC HEATING ELE MENT T HI-LIMIT ST A T LINE VOL T AGE CONTROLLER W A T ER T EMP E RA TURE OPERATION SEE PAGE 11 FOR COMPONENT NAMES / NUMBERS 1. Pressing [...]

  • Page 13

    SERVICING INSTRUCTIONS — ELECTRICAL 3 5 4 20 32 18 7 8 15 17 4 E-MA XLX ELECT RICAL COMPO NENT 12 0V UNIT S 120/ 2 40V UNIT S 3 PROBE, TEMPERATURE (THERMIS TOR) 4 THERMOSTAT, HI-LIMIT 5 GROMMET 7 PROBE, W ATER LEVEL 8 SLEEVE, W ATER LEVEL PROBE 15 ELEMENT, W ATER HEATING 17 ASSEMBLY, TRIAC & HEAT SI NK 18 BREW SOLENOID 20 CONTROLLER 32 FIL[...]

  • Page 14

    OPERATION SEE PAGE 13 FOR COMPONENT NAMES/NUMBERS 1. W ater enters at the inlet fi tting of the fill solenoid (32). The solenoid admits w a ter via a comm and from the controller. NOT E: The solenoid has an inter nal strainer. To clean the strainer: Shut off water supply. Unscrew the plastic cap protrud ing from the re ar of th e brewer. Rem ove th[...]

  • Page 15

    SERVICING INSTRUCTIONS — PLUMBING 13 ITEM DESCRIPTION P ART N0. USED ON 1 2 AS SEMBLY , WA T ER T A NK (12 0V ) 8350 0 2280 , 2 28 2 6G A S K E T , T A N K L I D 8 3 4 9 9 A L L 9 T ANK LI D 8350 4 ALL 10 RET AINI NG CLIP , T ANK LI D 83506 ALL 1 1 HOS E, OV ERF LO W (2 pc SI LI CO N E 4.5” LON G ) 86 0 14 A LL 12 HOSE , F AUCE T SU PPL Y (SIL [...]

  • Page 16

    SERVICING INST RUCTIONS — DE-LIMING HEAT ER TANK 1. Disconnect brewer form the electrical suppl y. Turn off the water suppl y and disc onnect water supply f rom the bre wer inlet fitting. 2. Remove the top panel or top warmer section to gain access to internal components. 3. Disconnect water level sensor and water temperature sensor from the cont[...]

  • Page 17

    SERVICING INSTRUCTIO NS — DIAGNOSTICS & TROUBLESHOO TING) If the E-Max™ LX goes into an error mode as outlined below , it will probably be necessary to reset the bre wer in order to test individual components. Note the reset proce dure below : * FOR “LOW W ATER” OR “OVERHEAT” ERRORS: PRESS & HOLD CANCEL FOR 3 SE CONDS, OR RE-ENE[...]

  • Page 18

    EXPLODED VIEW — AIRPOT MODELS 16[...]

  • Page 19

    PA RTS LIST — AI RPOT MODE LS 17[...]

  • Page 20

    EXPLODED VIEW — THERMAL SERVER MOD ELS 18[...]

  • Page 21

    PARTS LIST — THERM AL SERVER MODELS 19[...]

  • Page 22

    WIRING DIAGRAM 120 VOLT 20[...]

  • Page 23

    WIRING DIAGRAM 240 VOLT EXPORT MODELS 21[...]

  • Page 24

    Blo omfi eld Ind ustr ies, Inc. Divis ion of Carri er Refri ge ration In U S In C anad a PO Box 28 0, V erd i, NV 89439 T elep hone: 775-345 -0444 Servi ce: 88 8-492-278 2 F ax: 888-792-278 3 websit e: www . wellsbl oomfi eld. com T elep hone: 877-507- 1700 Servi ce: 90 5-507-170 0 Fa x: 905-507-1 777 website: w ww .bl oomcan.com Bloomfi eld Indust[...]