Go to page of
Similar user manuals
-
Stereo Amplifier
Bogen WV150
16 pages 0.55 mb -
Stereo Amplifier
Bogen V100
16 pages 0.69 mb -
Stereo Amplifier
Bogen CTS-1035
6 pages 0.36 mb -
Stereo Amplifier
Bogen V250
16 pages 0.69 mb -
Stereo Amplifier
Bogen CTS-1100
6 pages 0.36 mb -
Stereo Amplifier
Bogen M450
19 pages 0.71 mb -
Stereo Amplifier
Bogen TBA-15
6 pages 0.45 mb -
Stereo Amplifier
Bogen C10
4 pages 0.23 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Bogen M600, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bogen M600 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Bogen M600. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Bogen M600 should contain:
- informations concerning technical data of Bogen M600
- name of the manufacturer and a year of construction of the Bogen M600 item
- rules of operation, control and maintenance of the Bogen M600 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bogen M600 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bogen M600, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bogen service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bogen M600.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Bogen M600 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
M-Class Amplifier M300, M450, & M600 Models Inst allation and Use Manual © 200 1 Bogen Communications, Inc. All rights reserved. 54-2037-0 1 R3 02 1 0[...]
-
Page 2
Notice Every effort was made to ensure that the information in this guide was complete and accurate at the time of printing. How ev er , information is subject to change. Important Safety Information W ARNING: T o Reduce The Risk of Fire Or Electric Shock, Do Not Expose This Apparatus T o Rain Or Moistur e. Alwa ys f ollow these basic saf ety preca[...]
-
Page 3
Contents Page INTRODUCTION .................................................................................................. 1 Package Contents............................................................................................................... . 1 P ANEL DESCRIPTIONS ......................................................................[...]
-
Page 4
Intr oduction Bogen's M-Class amplifiers deliv er on what pr ofessional sound installers need most: Flexibility , Pow er , and Reliability . Flexibility The M-Class allows for the installation of up to 2 input modules, accepting inputs from micr ophones, telephone systems, stereo sour ces, mono sources, or daisy-chaining of amplifiers. Each M-[...]
-
Page 5
P anel Descriptions M-Class Fr ont P anel 1 . Status Indicators The Status LED is a multi-purpose indicator that lights in thr ee colors to show status. One for each channel. • Green - Amplifier is on and operating normall y . • Amber - Amplifier is in low-pow er consumption Sleep Mode . • Red - Amplifier has protected itself due to a fault c[...]
-
Page 6
P anel Descriptions M-Class Rear P anel 1 . Lo w-Impedance Outputs Accepts up to # 1 0 spade lugs for low-impedance speak er connections. 2. Channel Balance Only activ e in Dual Mono mode . Allows one channel’ s volume to be adjusted r elative to the other channel. 3/4. Effects Loop In/Out The effects loop connectors pr ovide an inser tion point [...]
-
Page 7
Installation Installation Components 1 . Rack Ears Prior to installing the amplifier , you will need to attach the installation rack ears if you intend to install the ampli- fier in a rack and complete the setup pr ocess. Remov e the 6 front most cov er screws on each side panel of the amplifier and attach rack ears as sho wn. 2. Dust Filter Insert[...]
-
Page 8
Installation V entilation The M-Class was designed to be placed on a table or rack-mounted. When rack mounted, the amplifiers can be stack ed one on top of the other for maximum use of the rack. An open air space of at least 4" must be pr ovided at the front air intak es of the amplifier , and the rear exhaust must ha ve at least a 4" gap[...]
-
Page 9
Installation Module Installation Installation T wo input module ba ys are a vailable to accept various Bogen input modules thereby allowing users to customize the amplifier to suit the needs of the installation. Read the instructions included with the module and mak e the desired jumper setting changes bef ore installing the module. The sleep switc[...]
-
Page 10
Connections Speakers Lo w-Impedance Speaker Connections When the amplifier is set to either the ster eo mode or the Dual Mono mode (see Operation section), low-impedance speak ers can be connected to either the "A" or "B" speak er output terminals. The amplifier is designed to w ork into speaker load impedances as low as 3.2 ohm[...]
-
Page 11
Operation Contr ols & Connector s Le vel Controls The front-mounted le vel contr ols act differently depending on the mode of operation. In the stereo mode, each lev el control determines the volume of the cor responding amplifier channel as in a typical amplifier . In the 70V Mono and Dual Mono modes, the controls ha ve a differ ent function a[...]
-
Page 12
Operation Effects Loop The effects loop connectors act as an insertion point for outboard signal pr ocessing equipment when the M-Class is operating in either the 70V Mono or Dual Mono modes. In these modes, the inputs and front panel contr ols form a 2: 1 mix er . Connect the Effects Loop Out to the input of the external signal pr ocessing equipme[...]
-
Page 13
Operation 70V Mono Mode Placing the 3-position switch to its right most position puts the amplifier in the 70V Mono mode of operation. The amplifier supplies a single channel of amplification in this mode (see 70V Mono Mode Block Diagram ). This mode also mix es the signals from each input module into a mono pr o- gram. Input signals of modules tha[...]
-
Page 14
Operation Modules Standard Input Module The M-Class is shipped with one input module pre-installed. The module pr o- vides 2 high-impedance, balanced, low- noise inputs, but can be r eplaced by other modules if desired. The input’ s connectors, labeled A & B, correspond to the similarly mark ed rear speak er connections and front panel contr [...]
-
Page 15
Applications Application Examples Application 1 : Simple 1 -Zone , 70V Mono telephone paging system with bac kgr ound music Background m usic plays thr ough the system when no page is being made . During a telephone page , the backgr ound music mutes to a pr edetermined level and the telephone page is hear d. When the page is complete, the backgr o[...]
-
Page 16
Applications Application 3: Global music/message buff ered and distributed to multiple amps with local override input for each amplifier Similar to the paging situation found at airport depar tur e gates, global music/messages pla y when no local page is present. During local page (from departure gate micr ophone), music/message mutes to predetermi[...]
-
Page 17
T r oubleshooting 1 4 • Amplifier not plugged in. • A C outlet dead. • Po wer switch off. • Break er (pow er switch) tripped. - T urn off, then turn bac k on. • 70V mono connections on amplifier incorr ect. • Poor/br ok en speak er wiring. • Defectiv e speakers. • Poor electrical connections at input. • Input cable routed near AC [...]
-
Page 18
Specifications 1 5 * Both channels driven at nominal line v oltage 1 20V A C , 60 Hz. ** Requires 20A, NEMA 5-20R T ype Receptacle . T echnical Specifications M600 M450 M300 P ower Output 70V Mono 4-ohm 8-ohm 1 200W @ 4 ohms 600W per channel* 400W per channel* 900W @ 5.5 ohms 450W per channel* 300W per channel* 600W @ 8 ohms 300W per channel* 200W [...]
-
Page 19
50 S pring S treet, Ramsey , NJ 07446, U.S.A. T el. 201-934-8500, Fax: 201-934-9832 Web Site: www .bogen.com / E-mail: info@bogen.com[...]