Go to page of
Similar user manuals
-
Speaker System
Bogen FH-1
1 pages 0.64 mb -
Speaker System
Bogen AE-112s2
1 pages 0.64 mb -
Stereo Amplifier
Bogen Wall Mount Modular Amplifier WMA80
6 pages 0.23 mb -
Stereo Amplifier
Bogen C35
12 pages 0.22 mb -
Stereo Amplifier
Bogen 600 ohm
1 pages 0.05 mb -
CD Player
Bogen CDC-3
16 pages 1.75 mb -
Speaker System
Bogen ALA-3
1 pages 0.6 mb -
Car Amplifier
Bogen ESYS1 (M)
4 pages 0.91 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Bogen UTI312, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bogen UTI312 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Bogen UTI312. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Bogen UTI312 should contain:
- informations concerning technical data of Bogen UTI312
- name of the manufacturer and a year of construction of the Bogen UTI312 item
- rules of operation, control and maintenance of the Bogen UTI312 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bogen UTI312 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bogen UTI312, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bogen service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bogen UTI312.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Bogen UTI312 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Zone Controller with Universal T elephone Interface UTI312 Model Inst allation and Use Manual © 2004 Bogen Communications, Inc. All rights reserved. Specifications subject to change without notice. 54-2 1 20-0 1 A0 4 11[...]
-
Page 2
© 2004 Bogen Communications, Inc. All Rights Reser ved. UL Appro ved Notice Every effort was made to ensure that the information in this manual was complete and accurate at the time of printing. How ev er , information is subject to change. FCC Statement (P art 1 5) - Radio Frequency Interf erence The Universal T elephone Interface generates and u[...]
-
Page 3
Contents 3 Introduction ......................................................4 V oice Channel ..............................................................4 Background Music ........................................................4 Signaling T ones ..............................................................4 Other Featur es ...................[...]
-
Page 4
4 Intr oduction The UTI3 1 2 Paging System is an expandable multi-zone paging and signaling system. The system pro vides the follo wing featur es and functions: V oice Channel • Expandable to 1 2 zones • T elephone interfaces: - loop start trunk - ground start trunk - station access (analog ring-up) - page port contact closure activation - page[...]
-
Page 5
5 P anel Descriptions UTI3 1 2 Callouts 1 . Ground Start T erminal - Connection for PBX ground. Used only when the ground start interface is selected. 2. Earth Ground T erminal - Provides connection to the UTI3 1 2 Earth Gr ound. This terminal can be connected to the GND STR T terminal when using the ground start interface if the UTI3 1 2 and the P[...]
-
Page 6
Installation Mounting W all Mounting Mounting to a plyw ood backboard or studs: 1 . On each side remo ve the f our screws in the corners and use them to attach the mounting flanges so that the flanges are facing the r ear of the unit. 2. Hold the unit lev el against the surface to which it will be mounted. 3. Using the k eyholes, mark on the mounti[...]
-
Page 7
T elephone Interface Wiring Connections & Setup T elephone System Connections The UTI3 1 2 connects to virtually any telephone system: PBX station lines and CO lines, PBX loop star t trunk ports, PBX ground start trunk ports, and page ports. Interface installation consists of setting the slide switches and connecting with modular (RJ 11 ) telep[...]
-
Page 8
8 PBX Loop Start T runk P ort In this configuration, the unit supplies a 24V talk batter y and loop curr ent detection. When the unit detects a loop resistance betw een Tip and Ring, it activates. When the loop opens, the page ends. The unit follo ws the status of the trunk port. Befor e configuring the UTI3 1 2 for a loop start trunk port, make su[...]
-
Page 9
9 T runk Disconnect The UTI3 1 2 includes a T runk Disconnect feature. The purpose of the T runk Disconnect featur e is to release the UTI3 1 2 from the trunk port in the ev ent a user does not hang up the phone properly after making a page. If the UTI3 1 2 does not detect voice f or the interface V O X time-out period, or if the interface default [...]
-
Page 10
10 Over ride Input The Over ride is a featur e that lets the caller take priority ov er all other paging functions and make a page. The center two conductors interface dir ectly to a Loop Star t T runk or a dedicated phone . When the trunk becomes active, the UTI3 1 2 goes into Ov erride mode. A contact closure and dry audio source can also be used[...]
-
Page 11
11 Other Connections Night Ringer Contact In addition to 90V ring activation of the Night Ring featur e , a contact triggered f eature is also a vailable. The night ringer by default sounds a simulated ring tone, but can be programmed to sound a chime tone to the night ring zone gr oup (same as 90V activation). T o connect to the night ring input: [...]
-
Page 12
12 ZX3 Module Connections ZX3 Module P aging Output Connections There ar e three zone paging outputs on the ZX3 module. The paging outputs are intended to connect to self-amplif ied speak ers, but ar e also compatible with amplifier inputs as w ell. The Tip (T) and Ring (R) connections are transf ormer -isolated audio outputs for driving up to 1 50[...]
-
Page 13
13 Contr ols P aging Le v el The ZX3 module has controls f or adjusting the audio level of each zone independently . These ser ve as master le vel controls that allo w for o verall zone control. Setting the initial volume to half is a g ood star ting point. If the speak ers ha ve their own le vel contr ol, then the installer will ha ve to determine[...]
-
Page 14
14 F eatur es & Operation Zones The UTI3 1 2 offers up to tw elve zones of paging. These zones are number ed 0 1 through 1 2 by default and do not requir e any pr ogramming, though they ma y be renumber ed using the Flexible Dialing feature. T o page to a z one: 1 . Dial the paging access number for y our telephone system. 2. Listen for the con[...]
-
Page 15
15 Auto Select Zone Gr oup Auto Select pro vides paging to a programmed zone gr oup when the unit is accessed without ha ving to enter any DTMF k eys.This feature is useful when v oice paging is alwa ys to all zones, but only certain zones are to r eceive tone trigger signals. No user -controlled zone selection is permitted f or paging when this fe[...]
-
Page 16
16 Code Call Zone Gr oup & T ones By default, the Code Call zone group is pr ogrammed to include all zones. The Code Calling featur e gives the caller the ability to trigger a series of chime tones to a zone group . By default, Code Call is disabled. There ar e tw o types of code calling: pattern and echo. P attern Code Calling Pattern code cal[...]
-
Page 17
17 Dialing Time-out Dialing Time-out can be enabled or disabled and by default is enabled. When enabled, the dialing time-out star ts as soon as the unit becomes active. The dialing time-out lasts 1 5 seconds and is reset with ev er y DTMF tone until the string is complete. If no DTMF is detected within those 1 5 seconds, there will be an err or to[...]
-
Page 18
18 System Pr o gramming System programming lets y ou set cer tain UTI3 1 2 options and tone featur es using the DTMF k eys of a telephone. All programming is accomplished thr ough the Override jack on the UTI3 1 2. T o program the UTI3 1 2 system, follow these instructions: 1 . Place the PR OGRAM/R UN switch to the PR OGRAM position. The gr een LED[...]
-
Page 19
19 T one Zone Groups In addition to paging zone gr oups, there ar e five additional zone gr oups, each with an associated tonal function.These are Ov erride zone group , Night Ring zone group , T one T rigger 1 zone group , T one T rigger 2 zone group , and Code Call zone group . By default, these zone groups are set to all zones. Each is programme[...]
-
Page 20
20 AUX Rela y Contact The UTI3 1 2 allows the installer to pr ogram a number of different parameters to contr ol the way in which the UTI3 1 2 AUX r elay contact activates.The UTI3 1 2 allows programming of which input e v ents (Over ride, T one T rigger 1 and 2, Page , and Night Ring) it will respond to , whether it will respond to the ev ent only[...]
-
Page 21
21 Below ar e some illustrative examples: Example 1 : Emergency T one/Emergency Announcement Bypass The T one T rigger 1 and Override inputs are used to pr ovide emerg enc y tones and live emergency announcements and when this happens any local attenuator s are to be bypassed to ensure that emerg enc y announcements can be heard. The AUX rela y con[...]
-
Page 22
22 Flexible Dialing Flexible Dialing permits the user to custom configur e the digit length and the access codes for zones and paging zone groups. The digit length for Flexible Dialing can be set to 2, 3, 4 or 5 digits.When Flexible Dialing is enabled, zones and paging zone groups ar e the same digit length and no * is used for accessing zone group[...]
-
Page 23
23 F eatur e Codes & Defaults Feature Feature Code Dat a Default Confirmation T one Confirmation T one Disable Confirmation T one Enable 001 002 002 Dialing Time-out Dialing T ime-out Disable Dialing T ime-out Enable 012 013 013 Pre-Announce T one Pre-Announce Disable Pre-Announce Beep Pre-Announce Chime 003 004 005 005 T runk Disconnect T runk[...]
-
Page 24
24 Feature Feature Code Dat a Default AUX Relay Override Disable Override Enable T one T rigger 1 Disable T one T rigger 1 Enable T one T rigger 2 Disable T one T rigger 2 Enable Page Disable Page Enable Night Ring Disable Night Ring Enable Delay No Delay Priority-Driven Event-Driven 070 071 072 073 074 075 076 077 078 079 080 081 082 083 071 073 0[...]
-
Page 25
25 Renumber Zone Group s Zone Group 1 Zone Group 2 Zone Group 3 Zone Group 4 Zone Group 5 Zone Group 6 Zone Group 7 Zone Group 8 Zone Group 9 Zone Group 10 Zone Group 1 1 Zone Group 12 Zone Group 13 Zone Group 14 Zone Group 15 Zone Group 16 Zone Group 17 Zone Group 18 Zone Group 19 Zone Group 20 Zone Group 21 Zone Group 22 Zone Group 23 Zone Group [...]
-
Page 26
26 Feature Feature Code T est Mode (factory use) T est Mode 990 Reset Reset Default 999 Setup T one T urn On T urn Off 000 Hang Up Notes to F eature Codes T o clear zones from zone gr oups, dial the feature code for that particular zone gr oup follow ed by the # sign. For example, to clear all zones from Zone Gr oup 1 , dial *0 1 # or to clear all [...]
-
Page 27
27 Specifications Input Impedance: 600 ohms (nominal) Input Lev el: - 1 0 dBm (nominal) V O X Sensitivity: -30 dBm Background Music Input Impedance: 20K ohms Music Input Lev el: - 1 0 dBm (nominal) Output Lev el: - 1 0 dBm (nominal) Output Impedance: 8 ohms Speak er Drive Ca pacity: 1 50 per output Timer Duration (both defeatable): Default: 1 0 sec[...]
-
Page 28
28 Block Dia gram, UTI3 1 2 * Ground points marked with an asterisk must not be connected to Earth Ground when GND ST terminal is connected to Earth Ground.[...]
-
Page 29
Block Dia gram, ZX3 29 * Ground points marked with an asterisk must not be connected to Earth Ground when GND ST terminal is connected to Earth Ground.[...]
-
Page 30
Limited W arranty 30 The UTI312 is warranted to be free from defects in material or workmanship for two (2) years from the date of sale to the original purchaser . Any part of the product covered by this warranty that, with normal installation and use, becomes defective will be repaired or replaced by Bogen, at our option, provided the product is s[...]
-
Page 31
31[...]
-
Page 32
50 S pring S treet, Ramsey , NJ 07446, U.S.A. T el. 201-934-8500, Fax: 201-934-9832, www .bogen.com[...]