Go to page of
Similar user manuals
-
Home Security System
Bosch Appliances MIC400
3 pages 0.23 mb -
Home Security System
Bosch Appliances IVMD 1.0
44 pages 1.16 mb -
Home Security System
Bosch Appliances PLE-10M2-EU
34 pages 2.78 mb -
Home Security System
Bosch Appliances WZ16
20 pages 0.81 mb -
Home Security System
Bosch Appliances 3.5
498 pages 31.95 mb -
Home Security System
Bosch Appliances DVR4C
14 pages 2.18 mb -
Home Security System
Bosch Appliances D1265
92 pages 5.64 mb -
Home Security System
Bosch Appliances DS422I
4 pages 0.15 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Bosch Appliances D7212GV4, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bosch Appliances D7212GV4 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Bosch Appliances D7212GV4. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Bosch Appliances D7212GV4 should contain:
- informations concerning technical data of Bosch Appliances D7212GV4
- name of the manufacturer and a year of construction of the Bosch Appliances D7212GV4 item
- rules of operation, control and maintenance of the Bosch Appliances D7212GV4 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bosch Appliances D7212GV4 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bosch Appliances D7212GV4, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bosch Appliances service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bosch Appliances D7212GV4.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Bosch Appliances D7212GV4 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
en Owner's Manual Supplement Control Panels D9412GV4/D7412 GV4/D7212GV 4[...]
-
Page 2
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement 2 Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 System Requirements Minimum system requirements for Classification in accordance with ANSI/SIA CP-0 1-2007: • UL Listed and Classified control unit Model D9412GV4, D7412GV4, or D7212GV4 • UL Listed and Classified keypad Model D125[...]
-
Page 3
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 3 1.0 Introduc tion 4 2.0 General Commands 4 2.1 Two-M an Rule 4 2.2 Early Am bush 5 2.3 Easy Exit Control 5 2.4 Passcode Follows Scope 6 2.5 Passcode Cont rolled Menu 7 2.6 Walk Tests 8 2.7 Door Acti vat ed Custo m Funct ion 11 2.8 Pas[...]
-
Page 4
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement 4 Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 1.0 Introduction This document supplements the Security System Owner’s Manual (P/N: 71-06633-000) wi th the fe atures for the GV4 Series. The instructions for the commands li sted in this document replace those commands in the Secur[...]
-
Page 5
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 5 2.2 Early Ambush 2.2.1 Description Early Ambush adds an extra step to the disarming process by requiring the entry of an addition al passcode to confirm that the area is secure. The second passcod e can be same as the first or differe[...]
-
Page 6
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement 6 Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 2.3.2 Using Easy Exit Control Switching armed states fro m Master to Perimet er: 1. Ensure that the keypad shows id le master armed text. 2. Press the [COMMAND] key. The keypad shows SYSTEM COMMAND . 3. Press [3] to Perimeter Arm. 4. [...]
-
Page 7
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 7 2.4.2 Using Passcode Follows Scope Arming from a k eypad with Panel Wide scope and Passcode Follows Scope enabled: 1. Ensure that the keypad shows id le disarmed text. 2. Ensure that you have a valid passcode with the authority to Pas[...]
-
Page 8
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement 8 Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 2.5.2 Using Passcode Controlled Menus On a D1255 Keypad 1. Press the [ESC] key. The keypad shows ENTER PASSCODE . 2. Enter your passcode by pressing the passcode digits followed by the [ENT] key. The first menu item for which you have[...]
-
Page 9
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 9 Table 1: Walk Test Menu Access Test Type Command Sequence Menu Function Na me Point Types Tested Walk [COMMAND][4][4] WALK TEST ? Visible Perimeter and Interior Fire [COMMAND][5][8] FIRE TEST ? Fire and 24- hour Invisible Not a pplica[...]
-
Page 10
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement 10 Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 Table 2: Hardware States of Points Display Text Hardware State 1PT### NORMAL HW Normal 1PT### OPEN HW Opened 1PT### SHORT HW Shorted 1PT### MISSNG HW Missing 9. Activate the point’s sens or and observe the appropriate state change.[...]
-
Page 11
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 11 The point state can be NORMAL , OPEN , SHORT , or MISSING . 7. Activate the point’s sens or and observe the state change. 8. Repeat Steps 5 through 7 until all points are tested. 2.7 Door Activated Custom Function 2.7.1 Description[...]
-
Page 12
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement 12 Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 I have One of the following Passcode Functions configured: Arm / Disarm (default) - All areas within the scope of the user and keypad have their arm state changed. If the current area is armed, it will disarm. If the current area is [...]
-
Page 13
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 13 The Dual Authentication proce ss is also valid if the access credential is presented first. Access credentials are usually a token or a card and are provided by your dealer. The control panel requires the pa ssc ode and the credentia[...]
-
Page 14
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement 14 Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 On a D1260 Keypad 1. Activate the door’s custom functi ons. Refer to Secti on 2.7.2 Using Door Activated Custom Functions . 2. Ensure that the display shows id le disarmed text. 3. Press the Menu softkey to enter the fu nction list[...]
-
Page 15
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 15 You can use the function list in place of steps 2 and 3 to start this function. 1. Press the [MENU] key to enter t he function list. 2. Press [NEXT] repeatedly until you reach the DOOR CTRL? prompt. 3. Press [ENT]. 4. The first sub-f[...]
-
Page 16
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement 16 Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 Table 3: Key to Symbols Symbol Description --- Door is not active, not in scope, or user does not have access level authority C Door is timed door sequence U Strike and shunt are latched active (held open) X Strike and shunt are deac[...]
-
Page 17
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 17 The display shows UNLOCK DOOR 1 2 3 U 5 6 7 8 This indicates that all do ors are in a normal stat e, except for Door 4, which is unlocked. 4. Press [ESC] to leave this sub-fu nction, or enter another door number to unlock. 2.10.5 Sec[...]
-
Page 18
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement 18 Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 Each of these sub-functions acts as a toggle switch. To return a door to its normal state, follow the same procedure used to change its state. For example , if Door 3 is secured, to return it to its normal state, at the SECURE DOOR? [...]
-
Page 19
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 19 6. The display shows DELETE USER ##? . Press [ENT] to de lete user, and USER DELETED appears. If the user number is not in the system, NOT IN USE appears. If you made an error and do not wish to delete this user, press [ESC]. 2.12 Ad[...]
-
Page 20
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement 20 Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 7. ENTER NEW CODE appears. Enter the new passcode followed by [ENT]. ENTER AGAIN appears. 8. Enter the new passcode a second time for confirmatio n. Press [ENT]. The display shows PASSCODE ADDED (or PASSCODE CHANGED if the user numbe[...]
-
Page 21
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 21 You can also use the function list in place of steps 2 and 3 to start this function. 1. Press the Menu softkey to enter the function l ist. 2. Press the Next softkey until you reach the Add/Change User? prompt. 3. Press the correspon[...]
-
Page 22
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement 22 Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 Systems With Access Control If your system includes access control features, such as card readers at doors, the following prompts can appear during the ADD USER? procedure. On a D1255 Keypad ADD CARD? (CHANGE CARD?) 1. If the user ha[...]
-
Page 23
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 23 2. Press the [COMMAND] key. The display shows *System Command*. 3. Press [5] and [6]. Enter passcode if necessary. 4. At the USER KEYFOBS? prompt, press [ENT]. 5. ENTER RFID appears. Press [ENT]. 6. USER ###: KEYFOB appears scrolling[...]
-
Page 24
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement 24 Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 On a D1260 Keypad 1. From the Add/Change Menu press the Keyfob softkey. 2. Configure RF Keyfob for this user? appears. Press the Yes softkey. 3. Press the Add Keyfob softkey. Keyfob User (###) RFID: Not Assigned appears. 4. Press the[...]
-
Page 25
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 25 Replac e a User Key Fob On a D1255 Keypad 1. At the USER KEYFOBS? prompt, press [ENT]. 2. ENTER RFID appears. Press [NEXT] until REPLACE KEYFOB appears. Press [ENT]. 3. KEYFOB USER: ### appears scrolling with AUTO-LEARNED if the keyf[...]
-
Page 26
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement 26 Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 3. KEYFOB USER: ### appears scrolling with AUTO-LEARNED . Press [ENT] to remove a keyfob. 4. If successful, KEYFOB REMOVED appears. KEYFOB USER: ### appears scrolling with NOT ASSIGNED . Press [ESC] to exit. 5. If not successful, an [...]
-
Page 27
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 27 3.0 SIA CP-01 Compliance Information Warning: The default programming for the control panel includes a 30-secon d communication delay for a larms on non-fire zone types. It can be re moved (o r increase d to 45 sec) at the option of [...]
-
Page 28
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement 28 Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 3.3 User-Caused False Alarms, Arming the System 3.3.1 Exit Time Defaults The SIA standard calls for Exit Ti me to range from 45 sec t o at least two min (not to exceed 255 sec). The default is 60 sec. 3.3.2 Exit Tone The SIA standard[...]
-
Page 29
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 29 3. The user does not return to s top Entry Delay. The Entry Delay time expires. 4. The control panel starts the alarm transmission sequence, accompanied by an Ex it Error report. 3.3.5 Master Arm − No Exit Feature (Unva cated Premi[...]
-
Page 30
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement 30 Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 3.5 Arming and Disarming with Keyswitches Arming Beeps and Flashes The SIA standard requires that the control panel p rovide a means to annunciate a change in arming state made from a Keyswitch. The Alarm Bell output pulses on tw ice[...]
-
Page 31
D9412GV4/D7412GV4/D 7212GV4 | Owner's Manual Supplement Bosch Security Systems, Inc. | 9/11 | F01U24522 4-02 31 3.6.3 Alarms Acknowledged within the Ab ort Window If the end user acknowledges an alarm within the Abort Window: • The alarm output is silenced. • No alarm, restoral, or cancel reports are sent. • No alarm, restoral, or cancel[...]
-
Page 32
Bosch Security S ystems, Inc. 130 Perinton Parkway Fairport, NY 14450 USA www.boschsecurity. com © Bosch Security Systems, Inc., 2011[...]