The rules should oblige the seller to give the purchaser an operating instrucion of Bosch Appliances GWH-635-ES, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bosch Appliances GWH-635-ES one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Bosch Appliances GWH-635-ES. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Bosch Appliances GWH-635-ES should contain:
- informations concerning technical data of Bosch Appliances GWH-635-ES
- name of the manufacturer and a year of construction of the Bosch Appliances GWH-635-ES item
- rules of operation, control and maintenance of the Bosch Appliances GWH-635-ES item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bosch Appliances GWH-635-ES alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bosch Appliances GWH-635-ES, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bosch Appliances service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bosch Appliances GWH-635-ES.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Bosch Appliances GWH-635-ES item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Water heat ers for u se with Natural an d L.P.G. GWH-635-ES T emperat ur e Modulat ed wit h Elec t ronic Ignit ion Suit able for heat ing pot able w ater only - Not a pproved fo r spac e heat ing purpose s (Intend ed for vari able fl ow applicatio ns with multiple t apping poi nts) GWH- 635-ES -N GWH- 635-ES -L 6 720 607 072 (04.03) JS Warn ing: I [...]

  • Page 2

    6 720 607 072 2 Index Index 1 Warning 2 2 Applianc e details 4 2.1 Features 4 2.2 GWH-635-ES Speci fications (Technical d ata) 4 2.3 Dimensions an d Minimum installation clearances 6 2.4 Genera l rules to follow for safe operation 7 2.5 Proper location for installing your heater 7 2.6 Cle arances 8 2.7 Mounting installation 8 2.8 Combustion air req[...]

  • Page 3

    6 720 607 072 Warning 3 What t o do if you s mell gas • Clos e gas v alve. O pen w indows. • Do not t ry to li ght any ap pliance. • Do n ot t ouch a ny e lectrical switch; do not use a ny phone in your buildi ng. • I m me di at el y c a ll yo ur ga s su pp li er f ro m a n ei g hb or ’s phone. F ollow the ga s sup plier’s in structio n[...]

  • Page 4

    6 720 607 072 4 Applia nce de tails 2 Applianc e details 2.1 Featur es Parts • Tou ch Pa d interfa ce contro l • High power pre-mix compact burner with low Nox emissions • Modulating Gas Valve with constant gas:a i r ratio contr ol • Modulating water valve for improved c omfort and tempe rature co ntrol. Safet y • Flame sensor (i onizatio[...]

  • Page 5

    6 720 607 072 App lia nce details 5 • Minim um recommended water pressure: 30 PSI (2.07 bar) • Connecti ons: – Bottom of heate r Comb ustion •N O x ≤ 55 ppm •C O ≤ 250 ppm •C O 2 level set from fact ory, see cha pter 9.1. Dimens ions • Dep th (i n): 8 ½ ” (2 20 mm ) • Width (in): 1 5 ¾” (400 mm) • Heigh t (in): 23 ½” [...]

  • Page 6

    6 720 607 072 6 Applia nce de tails 2.3 Dimension s and Minimum ins tallation clear ances Fig. 5 Dimension s 1 Cover 2 On/Off switch 3 Rese t butt on 4 LCD di splay 5 Program bu tton 6 Temperature buttons Fig. 6 M inimum clearances Model GWH-635- ES TOP (A) 12” FRONT (B) 4” BACK 0” SIDES 4” FLOOR (C ) 12” VENT DIAMETER 3” Table 1 M inim[...]

  • Page 7

    6 720 607 072 App lia nce details 7 2 . 4 G e n e r a l r u l e s t o f o l l o w f o r s a f e operatio n B 1. Y ou shoul d fol low thes e instruc tions when y ou instal l your h eater. In the Un ited S tates: T he i n s t a l l a t i o n m u s t c o n f o r m w i t h l o c a l co d e s o r , i n t h e absence of local codes, the National Fuel Gas[...]

  • Page 8

    6 720 607 072 8 Applia nce de tails 2.6 Cleara nces The GWH- 635-ES is design cert ified for installat i on o n a comb ustible wall (see 2. 7 Mo unting installatio n) provid ed the floor cover ing bel ow the heate r is noncom bustibl e. For installation s in an alcove or closet, mainta in the min imum cleara nces to comb ustible and non-c ombustibl[...]

  • Page 9

    6 720 607 072 App lia nce details 9 – b) In un confined s paces in buildi ngs of convent ional frame, ma sonry, or metal const ruction , in filtrati on air is normal ly adequat e t o provide air for combustion. • App liance s lo cated in confi ned spaces : The confined spa ce m ust be pro vided w ith tw o perm anent open ings, one commenc ing w[...]

  • Page 10

    6 720 607 072 10 Applia nce de tails The maximum flue gas exhaust t emperature on the GWH -635-ES is 437°F ( 225°C) Venting Optio ns Exhaust vent diameter and material * Exhaust ven t maximum length * Exhaust vent minimum length Comb ustio n air pipe diameter and ma terial Combustion air pipe maxi mum length Vent pipe clearances with in an unencl[...]

  • Page 11

    6 720 607 072 App lia nce details 11 The ap pliance should be located a s c lose to the point of termina tion as poss ible. The maximum ven t length is 26 feet ( 8 m) with one 90 degre e elbow. Subtra ct 2½ feet from the total ve nt len gth for each additional 90° elbow used (a maximum o f three 90 ° elb ows a re p e rm i tt ed in t h e to ta l [...]

  • Page 12

    6 720 607 072 12 Applia nce de tails Room sea led ins tallation (TWIN PIPE SYSTEM) Fig. 12 Combus tion air pipe: ≤ 26 ft (8 m) Exha ust vent pipe: ≤ 26 ft ( 8 m) A con densate t rap (drai n t ee) must be used in any side w a l l in s t al l a t io n i f t he t o t a l e x h a u s t v e nt l en g t h i s g r e at e r than or equ al to 5 feet ( 1[...]

  • Page 13

    6 720 607 072 App lia nce details 13 Recomm ended e xhaust vent te rminator position Fig. 16 * Subject to local c odes and anticipat ed snow level ** Other equip m ent that op erates with a mechanic al air inlet may require great er distances, reference m anufact urer's instructio ns Ref. Description Minimum distan ce A Directly below an openi[...]

  • Page 14

    6 720 607 072 14 Applia nce de tails Supportin g the exhaust vent sys tem and the use of an externa l conden sate t rap Extern al c ondens ate tr aps B A conden sate trap must be used in any sidewa l l exha ust vent instal lations w hen the tota l v ent l ength is ≥ 5 ft (1. 5 m) OR the vent p ipe pa sses t hrough an unheat ed space (below 6 0F).[...]

  • Page 15

    6 720 607 072 App lia nce details 15 Fig. 20 Vert ical venting installation - Masonry Chimney (combusti on air piping not being shown) A cond ensate tr ap (drain t ee) must b e us ed for a ny vertica l e xhaust vent installati on. T he condensa te t rap should be positioned as nea r to the t op of the heat er as possible. 2.10 Gas piping & conn[...]

  • Page 16

    6 720 607 072 16 Applia nce de tails FOR NA TU RAL GAS Maxi mum Capac ity o f pip e in Cubic Fee t of Ga s pe r Hour fo r Gas Press ure of 0 .5 Ps ig or less and a Pres sure drop of 0. 3 in Water Col umn (0 . 75mba r).(Based on a 0.60 Specifi c Grav ity G as) Btu n u mber s given in thou sands. Fig. 22 Follow bo xed numbers f or p iping jus t on e [...]

  • Page 17

    6 720 607 072 App lia nce details 17 2.11 Gas line sizing B It i s stro ngly recom mended that the Natur al Gas pipe be Bla ck Iron p ipe the entire distanc e from t he outside meter to th e inlet of the g as co nnection. ¾” B l a c k I r o n p i p e u p t o 2 0 f e e t ( 6 . 1 m ) a n d 1 ” B l a c k I r o n pipe up to 70 feet (21.34m) distan[...]

  • Page 18

    6 720 607 072 18 Applia nce de tails 2.13 Water con nections W h e n f a c i n g t h e h e a t e r , t h e ¾ ” c o l d w a t e r i n l e t i s o n t h e b o t t o m r i g h t a n d t h e h o t w a t e r o u t l e t i s o n t h e b o t t o m left . Install the hea ter centrall y in the build ing if possi ble and ma ke hot water pip ing runs as sh[...]

  • Page 19

    6 720 607 072 App lia nce details 19 2.14 Ele ctrical conne ctions The GW H-635 -ES requi res an elec trical po wer sup ply f r o m a 1 2 0 V A C 6 0 H z c i r c u i t a n d m u s t b e p r o p e r l y ground ed. A means f or switching off th e 120VAC power supply must be provided. The heater is wired as shown in the wiring diagr am (chapter 6, Fig[...]

  • Page 20

    6 720 607 072 20 Applia nce de tails When the hea ter is i n op eration you wi ll hear its power vent fan and burner opera ting. Upon turning off the hot water flow the p ower vent fan will cont inue to operat e f o r u p t o 6 0 s e c o n d s t o e x h a u s t a l l f l u e g a s e s . T h e power ve nts fan sp eed is varia ble depen ding on th e [...]

  • Page 21

    6 720 607 072 Operat ion inst ructions 21 3 Operation in structions Fig. 26 1 On/O ff switch 2 Reset button 3 Progr am Ke y 4 Increasing temperature se lector 5 Decreasing temper a ture se lector 6 LCD displ ay 3.1 Power On B T o st art the a pplia nce switch the bu tton to pos ition ( I ). LCD displa y the def ault tempe rature - temp erature fact[...]

  • Page 22

    6 720 607 072 22 Operat ion ins tructi ons Setting the w ater tempera ture The desire d temp erature o f the hot w ater can be adjuste d on t he front control p anel of t he heater. The GWH-635 -ES has a n e lectronica lly con trolled gas valve tha t modul ates the burner input in response to both varyin g hot wate r flow rates and/or changes in an[...]

  • Page 23

    6 720 607 072 Operat ion inst ructions 23 3.3 Use of remote co ntrol accessory Fig. 30 R emote control The wirel ess re mote control a ccessory and the tempera ture sel ector b uttons on th e front of the water heate r operat e ident ically. Cont act your distr ibutor or CEC to o rder if t he re mote control access ory is prefer red. Modifica tion [...]

  • Page 24

    6 720 607 072 24 Maint enance and se rvice 4 Maintenance and service The unit shoul d be checked once a year by a gas technic ian. If rep airs are need ed, the re pairs sho uld be done b y a ga s tech nician To r emov e fron t cov er B R e m o v e p l a s t i c d e c a l s o n f r o n t p a n e l ( P a g e 5 , F i g . 4). B Lo o se n t he tw o P hi[...]

  • Page 25

    6 720 607 072 Troubleshooting 25 Test by following 4th bullet under BURNERS DO NOT IGNITE WHEN HOT WATER IS TURNED ON. LOW WATER FLOW/PRESSURE • T o o m a n y h o t w a t e r a p p l i c a t i o n s a r e b e i n g us ed si m u lt an e ou s ly or to o mu c h fl o w i s be in g demande d The G WH-635 -ES will e ffectively su pport two 2.0 - 2.5 gp[...]

  • Page 26

    6 720 607 072 26 Troubleshooting Display Cause Solu tion E9 Temperature limiter opened circuit (over heat). Tri ps at 22 0F (104C) . Check connections.* Check heat exchanger con dition.* EA No ionization during safety time (safety t i me out). Check gas pr essure.* Check that gas is not diluted with air, as a result from recent gas pipel ine rework[...]

  • Page 27

    6 720 607 072 Electr ical diag ram 27 6 Electrica l diagram Fig. 36 Electrical scheme 1 Intlet water temp erature sensor 2 Ioniz ation sensor 3 Water flow sensor 4 Over heat protection 5 Temperature limiter 6 Gas val ve 7 Fan 8 Water valve 9 AC Plug 10 Ignit ion ele ctrode 11 Dis play PCB 12 ON/OFF switch 13 Fuse T 1,25 A 14 Fuse T 3,15 A 15 Ter mi[...]

  • Page 28

    6 720 607 072 28 GWH-6 35-ES Func tional s cheme 7 GWH -635-ES F unction al sch eme Fig. 37 Func tional scheme[...]

  • Page 29

    6 720 607 072 Inte rior c ompo nent s dia gram an d parts list 29 8 Interior components diagram and parts list 8.1 Interi or compo nents Fig. 38 C omponents 1 Cover 2 On/O ff switch 3 Reset button 4 LCD displ ay 5 Program b utton 6 Temperature sw itches 7 Flue gas c ollector 8 Mi xer 9 Heat e xchanger 10 Obs erva tio n win dow 11 Inle t ai r duct 1[...]

  • Page 30

    6 720 607 072 30 Inte rior c omponent s dia gram a nd pa rts lis t 8.2 Comp onents diag ram Fig. 40 Comp onents Diagram[...]

  • Page 31

    6 720 607 072 Inte rior c ompo nent s dia gram an d parts list 31 8.3 Parts list Item Descri ption Reference 1 Front cover 8 7 05 42 1 83 7 2 Shield 8 7 05 506 66 1 3 Heat exc hanger 8 7 05 406 285 4 Heat exc hanger top gask et 8 7 04 70 1 052 5 Clip 8 7 1 6 1 02 60 7 6 Heat exc hanger bottom gasket 8 7 04 70 1 054 7 O-ring 8 700 205 1 4 7 8 Temper[...]

  • Page 32

    6 720 607 072 32 Specia l adjust ment for measur ing and ad justin g CO2 level s 9 Special adjustment for measuring and adjusting CO 2 levels The CO 2 can only be adjuste d by a certif ied gas techni cian w ith a calibrat ed CO 2 ana lyzer . 9.1 Adjust ing the uni t Fact ory set tings of this applian ce are listed in table 7. Further adju stment is[...]

  • Page 33

    6 720 607 072 Specia l adjus tment for mea suring and adju sting CO2 lev els 33 Fig. 43 Adjusting Leave “Program” mod e B Turn ON/OFF switc h in position OFF and then ON again . i NOTE: turn ing screw clockw ise decreases CO 2 lev el, turning coun terclock wise inc reases it. Caution: Faulty igniti on or noisy operation ma y occ ur if CO 2 leve[...]

  • Page 34

    6 720 607 072 34 Protect ing the environ ment 10 Protecting t he environment Packin g Th e p ack ing box may b e fu lly rec yc led as c onf ir med by the rec ycling symb ol . Component s Many parts in the he ater can be fully rec ycled in the en d o f t h e p r o d u c t l i f e . C o n t a c t y o u r c i t y a u t h o r i t i e s f o r inform ati[...]

  • Page 35

    6 720 607 072 Fifteen Year Limit ed Warr anty 35 11 Fifteen Year Limited Warranty Gene ral BOSCH PRO w ater h eaters are wa rranted by t he Manufa cturer (BO SCH) through Co n tro lled Energy Corp. Contro lled Energy Corp. (CEC) will furnish a replac ement heat excha nger and w ill furni sh a repla cement of any oth er par t whi ch fails in nor mal[...]

  • Page 36

    Replacemen t Parts available from North Americ an Distributor CONT RO L LE D E N ERG Y CORP . 340 Mad Ri ver Park W aitsfie ld, V ermont 0 567 3 Phone 86 6-330- 27 30 Fax (802) 496-6924 www .protan kless.co m techsupport@protankle ss.com VU L CAN O T e rmodomésticos S.A . Estra da de Cacia 380 1 - 856 Aveir o - PO RTUGAL Recyc led paper © 2004 Co[...]