Go to page of
Similar user manuals
-
Water Heater
Bosch GWH 2700 ES LP
60 pages 6.5 mb -
Water Heater
Bosch AE125
12 pages 4.23 mb -
Water Heater
Bosch 125B LP
24 pages 6.73 mb -
Water Heater
Bosch 125HX LP
18 pages 8.21 mb -
Water Heater
Bosch W11P
8 pages 3.5 mb -
Water Heater
Bosch 125HX NG
20 pages 8.21 mb -
Water Heater
Bosch Model GWH 425
28 pages 3.5 mb -
Water Heater
Bosch GWH 425 EF
26 pages 13.7 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Bosch 125B LPS, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bosch 125B LPS one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Bosch 125B LPS. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Bosch 125B LPS should contain:
- informations concerning technical data of Bosch 125B LPS
- name of the manufacturer and a year of construction of the Bosch 125B LPS item
- rules of operation, control and maintenance of the Bosch 125B LPS item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bosch 125B LPS alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bosch 125B LPS, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bosch service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bosch 125B LPS.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Bosch 125B LPS item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
WARNING : Improper installation, adjustment , alterat ion, service or maint enance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or t he gas supplier . Upon completion of the installation, these instructions should be handed to the user of the applia[...]
-
Page 2
2 6 720 606 518 This well engineered, gas water heater has been specially designed to operate with incoming pre-heated water: It operates on the principle of heating water instantaneously “on demand”. When a hot water faucet is opened, cold water flows through the coils of the heat exchanger in the Aquast ar . This same flow opens the gas valve[...]
-
Page 3
3 6 720 606 518 D861_059 M I N I M U M I N S T ALLA TI ON C LE A R ANC ES F RO M C OM B U S TI B LE AN D N ON C OM B U S TI B LE MA TE R IAL S F O R AL COVE O R C L O S ET I NST ALLA TI O NS F RO NT VI EW S I DE VI EW AQU AST AR M ODE L 1 25B S MODEL 125BS TOP (A) 12 " FRONT (B) 4 " BACK 0 " SIDES 4 " FLOOR (C) 12 " VENT DI[...]
-
Page 4
4 6 720 606 518 PR OPER L OCA TION FOR I NST ALL I NG Y OU R HEA T ER C arefully select the location of your new heater. For your safety and for proper heater operation, you must provide an abundant supply of combustion air and a proper venting installation. The heater may still operate even when improperly vented. It will, however, be less efficie[...]
-
Page 5
5 6 720 606 518 WARNING: Flammable materials, gasoline, pressurized containers, or any other items or articles that are pot entially fire hazards must NOT be placed on or adjacent to the heater. The appliance area must be kept free of all combustible materials, gasoline and other flammable vapors and liquids. COMBUSTION AIR REQUIREMENTS The AquaSta[...]
-
Page 6
6 6 720 606 518 Fig. 1 - Mounting the Heater Fig. 2 - Incandescent Part icle T ray Illustrat ion The incandescent particle tray (shipped loose in the carton with the water heater) must be attached at the bottom of the water heater front cover at the time of installation. Use the screws provided. See figure 2 SUPPORT BOARD WALL STUDS 1” X 4 ” SP[...]
-
Page 7
7 6 720 606 518 VENTING V ent pipe connect ion. W AR NI NG : Do not reduce t he vent pipe size . S ee Fig. 3 for high alt itude inst allations The heater must be vented to the outside following all local ordinances and specifications for installing a gas appliance vent or chimney . The heater must be located as close as practicable to a vertically [...]
-
Page 8
8 6 720 606 518 MASO NRY CH I MN EY : Masonry chimneys shall be built and installed in accordance with N FP S 2 1 1 or local codes. A minimum 5” diameter gas vent pipe ( metal double wall T ype B ), or an approved clay flue liner or a listed c himney lining system must be used when venting into a naturally drafting, internal masonr y chimney . 6 [...]
-
Page 9
9 6 720 606 518 Fig. 3 – V ent Adaptor for High Altit ude Inst allations 5” X 6” ADAPT O R US ED ON HIGH A L TI TUD E T o check the draft : Close all doors and windows to the outside. T urn on all appliances that force air out of the building. These include all exhaust/ventilation fans, furnaces, clothes dryers, wood burning stoves, etc. Open[...]
-
Page 10
10 6 720 606 518 GAS CONNECTIONS and Gas Regulator NO TE: The Aquastar 1 25 B”S” is supplied wit h a gas pressure regulator that must be inst alled on t he heat er before attaching the gas supply line. See figure 5. Failure to install the gas regulator as shown in figure 5 will be a violation of CSA certificat ion of t he unit . T he regulator [...]
-
Page 11
11 6 720 606 518 The water heater must be isolated from the gas supply piping system by closing the manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or more than 0.5 psig. The water heater , including the pressure regulator provided with it, must not be operated at gas supply pressures in e[...]
-
Page 12
12 6 720 606 518 O PERA TIN G INST R U C T IONS Before proceeding with the operation of the heater make sure that the system is filled with water . Open the cold water inlet supply to the heater fully . Open a hot water faucet to permit the water to fill the heater and the piping and to eliminate the air trapped in the system Close the hot water fa[...]
-
Page 13
13 6 720 606 518 Fig. 8 - Characteristic Pilot Flame 3mm Correct gap between pilot burner tip and piezo electrode tip Piezo Electrode Air screen filter 1 0mm 3/8” Piezo Electrode Thermocouple T o clean t he pilot burner and/ or the pilot orifice : T urn off the gas at the unit . Remove the cover of the heater . T o do so, remove incandescent part[...]
-
Page 14
14 6 720 606 518 If some burners have yellow flames while others have good flames, it is likely that dust, lint or spider webs have partially clogged the burner venturis. Contact a gas service person to clean the remove and clean the burners. Mineral S c ale Build-up : The AquaStars heater , when operated at lower temperatures settings, do not accu[...]
-
Page 15
15 6 720 606 518 T o test the thermocouple , disconnect the thermocouple lead to the ECO. Insert a multi-meter probe into the thermocouple lead and attach or hold the other lead to the metal gas valve (DC common). Light the pilot flame and hold button, meter reading should be 24 mVDC or more. If the reading is 24 mVD C or more the thermocouple is g[...]
-
Page 16
16 6 720 606 518 See specifications on page 2. Unlike storage tank water heaters, the burners of a tankless water heater must be very powerful to heat water instantaneously since they do this only at the time hot water is actually being used. It is therefore imperative that the gas pressure requirement be met exactly . Insufficient gas pressure wil[...]
-
Page 17
17 6 720 606 518 1 . Heat exchanger 2 . Pilot assembly 3. Burner manifold gas pressure test nipple 4 . Main gas burner 5 . Pilot gas tubing 6 . Gas valve 7 . Piezo igniter 8 . Location of pressure tap screw 9. W ater valve 1 0. Gas inlet gas pressure test nipple 5 1 4 7 9 3 10 6 2 8 Fig. 1 0 - Diagram of AquaSt ar 1 25 BS[...]
-
Page 18
18 6 720 606 518 A Q 1 25 BS Fig. 1 1 - I NTER IO R COM P ONE NTS DIA G RAM AN D P ARTS LI S T[...]
-
Page 19
19 6 720 606 518 Fig. 1 1 INTERIOR COMPONENTS DIAGRAM AN D P ARTS LIST 1 25B S 1 Cov er 8 705 421 033 2 Cap cover 8 703 304 011 3 Water connection gasket 8 710 103 043 4 Draf t dive rtor 8 705 5 05 354 5 Heat exch anger 8 705 406 189 6 Hot w ater pipe 8 700 705 431 7 Cold water pipe 8 700 705 294 8 Heat exchang er w asher 8 710 103 045 9 Overheat s[...]
-
Page 20
20 6 720 606 518 Fig. 1 2 - Flow chart of Aquast ar 1 25 BS[...]
-
Page 21
21 6 720 606 518 LI M ITE D W AR R ANT Y Aquast ar General Aquastar water heaters are warranted by the Manufacturer ( BO SC H) through C ontrolled Energy Corp . C ontrolled Energy C orp. (C E C) will furnish a replacement heat exchanger and will furnish a replacement of any other part which fails in normal use and service within the applicable peri[...]
-
Page 22
VU L C ANO T ermod omést icos S.A. Estrada de Cacia 380 1 - 856 Aveiro - P ORTUGAL Recycled paper 3 1 e g a p e e s E L B A T E C N A N E T N I A M R A E Y Y R E V S E R A E Y 2 Y R E V S E R A E Y 5 - 3 Y R E V E E V L A V R E T A W E T A C I R B U L † E V L A V R E T A W D L I U B E R † N E E R C S R E T L I F R E T A W T C E P S N I † Y L[...]