Go to page of
Similar user manuals
-
Water Heater
Bradford-White Corp 705-B
2 pages 0.26 mb -
Water Heater
Bradford-White Corp TG-180E-N(X)
72 pages 1.81 mb -
Water Heater
Bradford-White Corp D4504S*F(BN
40 pages 1.55 mb -
Water Heater
Bradford-White Corp EF-100T-199
4 pages 0.21 mb -
Water Heater
Bradford-White Corp LD-WH6U3-1
2 pages 0.27 mb -
Water Heater
Bradford-White Corp 547-B
2 pages 0.24 mb -
Water Heater
Bradford-White Corp Copper Brute II Hydronic Boiler
64 pages 3.41 mb -
Water Heater
Bradford-White Corp BWCV
44 pages 3.27 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Bradford-White Corp MI100T*(BN, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bradford-White Corp MI100T*(BN one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Bradford-White Corp MI100T*(BN. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Bradford-White Corp MI100T*(BN should contain:
- informations concerning technical data of Bradford-White Corp MI100T*(BN
- name of the manufacturer and a year of construction of the Bradford-White Corp MI100T*(BN item
- rules of operation, control and maintenance of the Bradford-White Corp MI100T*(BN item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bradford-White Corp MI100T*(BN alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bradford-White Corp MI100T*(BN, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bradford-White Corp service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bradford-White Corp MI100T*(BN.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Bradford-White Corp MI100T*(BN item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
SERVICE MANUAL Atmospheric Gas Water Heaters Troublesh ooti ng Guide and Inst ructions for Ser vice (To be pe rf o rmed O NL Y b y quali fie d service pr o viders) Sa ve th is ma nual for fu ture r efere nce Manu al 2 3 8-46 64 7-0 0A Mode l s C ove re d by This Manu al : GX225S*B N GX155S*B N 25X78 B*N 55X80 B*N M1X R65T * ( BN,CX) MI7 5S*( BN,CX)[...]
-
Page 2
T able of Contents Page Ser vi ce P rocedure Tr ou ble shoo t ing C har t 3 - - - Therm ocouple T es ting an d Repl acem e nt 4 A G- I Pilot Assembl y Ins pe ction Cle anin g a nd Re pla c ement 5 AG- II Co mbi nation T hermostat/ Ga s V alve Tes ting and Replac ement 6 A G-I II B urne r O pera tion Inspection , Ad jus tm e nt, Cle aning and R epla[...]
-
Page 3
Troubleshooting Char t SYM PT OM PR OB A BL E CA US E CORR E CT IV E ACTION Pil ot w ill n o t li g ht 1 . No i n com ing g as or too l o w g as pr essu re. 2 . Gas c o ntro l k no b s et t o wr ong po siti o n. 3 . Pilot lig ht button n ot b ei ng f u lly d epr es sed whe n attem p ting t o li ght p ilot . 4. Pilot orifice o r pi lot tub e is o bs[...]
-
Page 4
T HERMOCOU PLE REPL A CEMENT Step 1. T u rn off g as supply to wat er heater . Rota te kno b of combination ther mosta t/g as v al ve to “O F F” po sit ion. Step 2. R e move out er jacket door. Step 3. Slide open inner c omb ustion chambe r do or. Step 4 Disconne ct therm oc ouple from co m bination therm ostat/g as valve (3/8" w re n ch).[...]
-
Page 5
PILO T ASSEM BLY INSP ECTION, CLEANING AND RE PLACEMENT Step 1. T u rn off g as supply to w ater he ater. Ro tate kn ob of co mb ination thermostat/gas valve to “OFF ” position. Step 2. R e move out er jacket door. Ste p 3. Sl id e op en in n er c omb ustion chambe r door. Step 4 Dis conne ct the rmocouple ( 3/8" w ren ch), pi l ot tube ( [...]
-
Page 6
SERV IC E P ROCE DURE A G-III Combination Therm ostat/Gas Valve Tes ting an d Rep lacement T he c o mbi nation therm ostat/g as val ve i s a n on r epai rable dev ice . I f t rou ble s hootin g has det ermined a p roblem with the c om binat ion the rmostat /gas v alve, it mu st be r eplac ed. If the b urner a nd/or pi l ot d o n ot f un ction, serv[...]
-
Page 7
See SE RVI CE PR OCEDURE AG -I TH ERMOCOUPLE TESTING M AGNET ASSEMBLY T E STI NG (Whi t e Rod g ers Control) SERV IC E P ROCE DURE A G-III Combination Therm ostat/Gas Valve Tes ting and Replacement Pa ge 7 Step 1. Follo wing the l ig hting instruction label o n the he ater, proceed t o light t he pilot an d allow to o perate f or thr ee m inutes . [...]
-
Page 8
SERV IC E P ROCE DURE A G-III Combination Therm ostat/Gas Valve Tes ting an d Rep lacement COMBI NATION T HERMOSTAT/G AS VALVE RE PLA CEMENT Step 1 . R ot ate k no b of the c omb inat ion t her m ostat /gas val ve t o the “OFF” position. Step 2. T urn of f gas s upply to water heater. Step 3. Disconnect gas supply line from com binat io n therm[...]
-
Page 9
SERV IC E P ROCE DURE A G-III Combination Therm ostat/Gas Valve Tes ting an d Rep lacement Step 7. Removal of combination th er mostat/gas valve. a ) Disconn ect mai n b urne r f e edl ine ( ¾” wren ch), p i lot tube (7 /16 " w rench) and th e rmoc oup l e (3/8 " w rench) fro m comb ina tion thermos tat/gas v alve & rem ove b urner[...]
-
Page 10
Step 1 . W i th main burner in oper ati on sl ide the inner c omb ustion chambe r door open. Step 2 . To adjust for proper burning, loosen the air shutter nut, rotate the shutter to close the opening in the burner, then slowly rotate the shutter until the yellow tips are minimized. Tighten the air shutt er nu t. Too much air will cause the flame to[...]
-
Page 11
St e p 3 . F u lly ins pect combu stion c hamb er for debris or car bon bui ld up. St e p 4. B urn er shoul d operat e as ad j usted in s tep 2, if no t, re peat p ro ced ure c ompensatin g air s hut ter position for prop er b urn er o pe ration with i nn er door close d. St e p 5 . I t m ay be necessar y to clean mai n bur ner or ma in burne r ori[...]
-
Page 12
Step 5. Disconne ct (u nscrew) M ain bu r ner ( sta mped st ee l b urner) f rom main b urn er ori fice or o n ca st i r o n b urners, l oose n ai r s hutter & discon nect (unscrew) fee dlin e from burner. Step 6 . R e mo ve ma in burner ori fice fr om fee d line (½” wren ch o n steel b urn er, 3/8 " wrench o n cast iro n). I nspe ct and[...]
-
Page 13
SER VICE PROC EDURE A G-V D ip Tube and A no de Ins pe ction and Re placemen t Page 13 St e p 1. R otat e kno b of c omb ina t io n t her m os ta t /ga s va l v e to “ O FF” p o sit i o n. St e p 2 . T u r n of f cold w ater suppl y t o heater. C onnec t h ose to d rai n spigot o f w ater he ater and r ou te to a n o p en drain. Op en a nea rb [...]
-
Page 14
Step 1. T u rn of f water supply to wate r heater. R otat e kn ob o f c ombi nation therm o stat /gas val ve to “OF F” p osition. Step 2. T u rn of f cold water sup ply t o heater . C onnec t h ose to dr ain spigot o f water he ater a n d route to an o pen d rai n. Ope n a ne arby h ot w ate r f auc et t o v en t h e ate r f or dr ai ning. Open[...]
-
Page 15
NOTES 15[...]
-
Page 16
Application & Sizing/ 800-523-2931 Fax/ 215-641-1612 Email parts@bradfordwhite.com techserv@bradfordwhite.com www .bradfordwhite.com www .bradfordwhitecanada.com[...]