Go to page of
Similar user manuals
-
Plumbing Product
Bradley Smoker 594
1 pages 0.1 mb -
Plumbing Product
Bradley Smoker E19-120A
4 pages 0.08 mb -
Plumbing Product
Bradley Smoker LD-3072/STD
5 pages 0.85 mb -
Plumbing Product
Bradley Smoker MG-2/BIR3
19 pages 0.69 mb -
Plumbing Product
Bradley Smoker SS-2/IR/STD
19 pages 0.26 mb -
Plumbing Product
Bradley Smoker CRS-3/IR
14 pages 0.59 mb -
Plumbing Product
Bradley Smoker MG-2/TT
20 pages 0.58 mb -
Plumbing Product
Bradley Smoker TDB3104
29 pages 0.8 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Bradley Smoker CRS-3/IR, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bradley Smoker CRS-3/IR one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Bradley Smoker CRS-3/IR. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Bradley Smoker CRS-3/IR should contain:
- informations concerning technical data of Bradley Smoker CRS-3/IR
- name of the manufacturer and a year of construction of the Bradley Smoker CRS-3/IR item
- rules of operation, control and maintenance of the Bradley Smoker CRS-3/IR item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bradley Smoker CRS-3/IR alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bradley Smoker CRS-3/IR, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bradley Smoker service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bradley Smoker CRS-3/IR.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Bradley Smoker CRS-3/IR item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
CRS-2/IR, CRS-3/IR Express® Crescent® Lavatory System CRS-Series Complies with T exas Accessibility St andards (T AS) for Juvenile Height applications. Inst allation Instructions P .O. Box 309, Menomonee Falls, WI 53052-0309 TEL. 1-800-BRADLEY F AX 262-251-5817 http://www .bradleycorp.com T able of Content s Dimensions . . . . . . . . . . . . . .[...]
-
Page 2
Express ® Crescent ® Lavatory System - CRS-Series CRS-2/IR, CRS-3/IR Installation Instructions 2 2/8/07 Bradley Corporation • 215-1330 Rev . K; EN 06-915 Express® Crescent® Lavatory System Dimensions 48" (1219) 26" (660) *34" (864) *20" (508) *37-3/8" (949) 8-1/2" (216) (mm) (mm ) (mm ) 3-3/8" (86) 17-3/8&qu[...]
-
Page 3
Express ® Crescent ® Lavatory System - CRS-Series Installation Instructions CRS-2/IR, CRS-3/IR 3 Bradley Corporation • 215-1330 Rev . K; EN 06-915 2/8/07 Inst allation Instructions Supplies required for inst allation: • (6) 3/8" wall anchors, bolts and washers to mount bowl to wall (min. pull-out force of 1,000 lbs.) • 1/2" NPT ho[...]
-
Page 4
Express ® Crescent ® Lavatory System - CRS-Series CRS-2/IR, CRS-3/IR Installation Instructions 4 2/8/07 Bradley Corporation • 215-1330 Rev . K; EN 06-915 * ADJUSTMENTS TO VERTICAL DIMENSIONS FOR V ARIOUS RIM HEIGHTS Rim Height Application Adjustment 34" Adult Height ADA, T AS Adult Height T AS Adult Height None, as shown 32" T AS Ages[...]
-
Page 5
Express ® Crescent ® Lavatory System - CRS-Series Installation Instructions CRS-2/IR, CRS-3/IR 5 Bradley Corporation • 215-1330 Rev . K; EN 06-915 2/8/07 Inst allation Instructions continued . . . Step 3: Inst all wall anchors 1. Measure and mark the centerline of the lavatory system on the wall. 3. Using cardboard template 186-131 1 provided, [...]
-
Page 6
Inst allation Instructions continued . . . Step 6: Inst all drain spud 1. Assemble the P-trap by (supplied by installer) connecting the 1-1/2" tubular pipe to the 1-1/4" tailpiece and to the 1-1/2" drain pipe stubbed out of the wall (see Figure 4). Step 7: Connecting Supply 1. Connect the 1/2" NPT female end of the stop/check va[...]
-
Page 7
Express ® Crescent ® Lavatory System - CRS-Series Installation Instructions CRS-2/IR, CRS-3/IR 7 Bradley Corporation • 215-1330 Rev . K; EN 06-915 2/8/07 Inst allation Instructions continued . . . Step 8: Electrical and supply connections NOTE: Refer to Figur e 6a below for CRS-2/IR or Figur e 6b on page 8 for CRS-3/IR. W ARNING: The Adaptive®[...]
-
Page 8
Inst allation Instructions continued . . . Step 8: Electrical and supply connections, cont’d. 6. Check the temperature when approximately 1.0 GPM water flow is reached and adjust if necessary (the range of the valve is 95°F–1 15°F (35°C–43°C). T o adjust the temperature, follow the procedure below: • Loosen temperature locking nut with [...]
-
Page 9
Express ® Crescent ® Lavatory System - CRS-Series Installation Instructions CRS-2/IR, CRS-3/IR 9 Bradley Corporation • 215-1330 Rev . K; EN 06-915 2/8/07 Inst allation Instructions continued . . . Step 9: Inst all the Optional Soap Dispenser For Expr ess® Cr escent® Lavatory System units with optional soap dispensers, see 215-1583. Step 10: I[...]
-
Page 10
Express ® Crescent ® Lavatory System - CRS-Series CRS-2/IR, CRS-3/IR Installation Instructions 10 2/8/07 Bradley Corporation • 215-1330 Rev . K; EN 06-915 Cleaning and Maintenance Instructions IMPORT ANT : Strong alkaline or acid-based chemicals and cleansers should not be used to clean the Crescent®. If these chemicals come in cont act with t[...]
-
Page 11
Express ® Crescent ® Lavatory System - CRS-Series Installation Instructions CRS-2/IR, CRS-3/IR 11 Bradley Corporation • 215-1330 Rev . K; EN 06-915 2/8/07 Solenoid V alve T roubleshooting CAUTION: T urn off water supplies to unit before troubleshooting. Problem: An individual operating station fails to shut off and drips. Cause: There is debris[...]
-
Page 12
Express ® Crescent ® Lavatory System - CRS-Series CRS-2/IR, CRS-3/IR Installation Instructions 12 2/8/07 Bradley Corporation • 215-1330 Rev . K; EN 06-915 1 2 3 4 5 6 7 8 9 8 DE S CRIPTION QTY . P ART NO . REF . 1 1 11 8 -307 V AL VE BOD Y , 1/4" CLO S ED 2 1 269-9 8 3 DIAPHRA GM 3 1 269-577 ARMA TURE 4 1 269-57 8 S PRING 5 1 269-1729 ARMA[...]
-
Page 13
Thermost atic Mixing V alve T roubleshooting NOTE: Befor e attempting to tr oubleshoot the valve or disassemble the components, check for the following conditions: • If stop/check valves ar e used, make sur e that they ar e fully open. • Make sur e that the hot and cold inlet pipes ar e connected pr operly , and that ther e ar e no cross- conne[...]
-
Page 14
Express ® Crescent ® Lavatory System - CRS-Series CRS-2/IR, CRS-3/IR Installation Instructions 14 2/8/07 Bradley Corporation • 215-1330 Rev . K; EN 06-915 V ernatherm™ Thermost atic Mixing V alve (S01-524) S trainer 173-028 T empered Line Adapter Assembly (S39-685) Option Thermostat 51 7 1 O-Ring 8 1 O-Ring Item Qty Description Repair Kit S65[...]