Go to page of
Similar user manuals
-
Thermometer
Braun PRT 1000 High speed
1 pages 1.92 mb -
Thermometer
Braun IRT 3030 - ThermoScan 3
1 pages 18.31 mb -
Thermometer
Braun IRT4520USSM
42 pages 1.71 mb -
Thermometer
Braun IRT6020
59 pages -
Thermometer
Braun IRT2020 - 6015 Thermoscan
24 pages 0.97 mb -
Thermometer
Braun Pro3000
63 pages 1.33 mb -
Thermometer
Braun IRT 3020
48 pages 1.24 mb -
Thermometer
Braun IRT 4020 ThermoScan
55 pages
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Braun 6012, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Braun 6012 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Braun 6012. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Braun 6012 should contain:
- informations concerning technical data of Braun 6012
- name of the manufacturer and a year of construction of the Braun 6012 item
- rules of operation, control and maintenance of the Braun 6012 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Braun 6012 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Braun 6012, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Braun service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Braun 6012.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Braun 6012 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
IRT 3020 IRT 3520 Type 6012 Type 6013 ThermoScan ® Thermo Scan / mem 6012136_IRT_3000_NA 28.10.2005 8:20 Uhr Seite 1[...]
-
Page 2
Internet: www .braun.com Manufactured by: Braun GmbH Frankfurter Str . 145 61476 Kronber g / Germany 6-012-136/00/X-05 USA Printed in Germany 6012136_IRT_3000_NA 28.10.2005 8:20 Uhr Seite 2[...]
-
Page 3
IRT 3020 8 12 12 13 13 b a ThermoScan 11 12 12 13 b a ThermoScan Thermo Scan / mem Thermo Scan / mem 11 IRT 3520 2 3 4 5 6 7 8 9 10 1 13 Configuration A Configuration B Configuration B Configuration A 6012136_IRT_3000_NA 28.10.2005 8:20 Uhr Seite 3[...]
-
Page 4
English The Braun ThermoScan thermometer has been carefully developed for accurate, safe and fast human body temperature measur ements in the ear . The shape of the thermometer prevents it fr om being inserted too far into the ear canal to damage the eardrum. However , as with any thermometer , proper technique is critical to obtaining accurate tem[...]
-
Page 5
• Axillary temperatures r eflect skin temperature which may not indicate core body temperature. • Oral temperatures ar e influenced by drinking, eating and breathing through the mouth. • Rectal temperatures often lag behind changes in cor e body temperature and there is a risk of cross-contamination. Body temperature Normal body temperature i[...]
-
Page 6
Product description 1. Lens filter 2. Probe tip 3. Probe 4. Lens filter detector 5. Lens filter ejector 6. Display (LCD) 7. LCD light button (IRT 3520 only) 8. /mem button (On/memory function) 9. Battery door lock 10. Battery door 11. Activation button 12. Label 13. T ravel case/protective cover/storage pouch (depending on configuration) Package co[...]
-
Page 7
T o help ensur e an accurate temperature reading, use the following technique: If you ar e right handed, hold the thermometer in the right hand and take the temperature in the right ear . If you are left handed, hold it in the left hand and use the left ear . 3. Perform an ear tug to straighten the ear canal. This gives the thermometer a clear view[...]
-
Page 8
T emperature taking hints • The right ear reading may dif fer from the reading taken at the left ear . Therefor e, always take the temperature in the same ear . • The ear must be free fr om obstructions or excess earwax build- up to take an accurate reading. • External factors may influence ear temperatures, including when an individual has: [...]
-
Page 9
Memory mode The last temperature taken befor e the thermo- meter powers down is stored in memory . T o enter the memory mode, press the /mem button. Even in memory mode, a new temperature can be taken provided that the r eady symbol is shown. IRT 3020 The last stored temperatur e is displayed along with the MEM symbol. T o quit the memory mode, pre[...]
-
Page 10
Changing the temperature scale This thermometer is shipped with the Fahrenheit temperatur e scale activated. If you wish to switch to Celsius (°C), proceed as follows: • T urn on the thermometer . (If it is already turned on, make sure it is not in memory mode.) • Press the /mem button and keep it pressed. Then pr ess and release the activatio[...]
-
Page 11
carrying Braun ThermoScan thermometers or at Braun Service Centers. • If you have accidentally placed the thermometer in your ear with- out a lens filter in place, be sure and clean the pr obe (see «Care and cleaning» and then apply a clean lens filter . Care and cleaning The probe tip is the most delicate part of the thermometer . It has to be[...]
-
Page 12
T roubleshooting Error message Situation Solution No lens filter is attached. Attach new , clean lens filter No lens filter is attached Make sur e probe tip is clean; and activation button was refer to section «Car e and cleaning» pressed while pr obe was in if necessary . the ear . Attach new , clean lens filter to stop error beeps. Ambient temp[...]
-
Page 13
Special situations The Braun ThermoScan thermometer has been shown in clinical studies to obtain accurate temperatures on persons of all ages. However , there ar e certain situations when the ear thermometer should not be used. These include but may not be limited to the following situations. • If there is blood or drainage in the external ear ca[...]
-
Page 14
Some people, like the elderly , infants under 90 days of age, those with compromised immune systems, or persons who take ster oids, for example are often unable to build a r esponse to illness or environmental conditions. These individuals may not have a fever when they are ill, or their elevated temperatur e may be lower than expected for the seve[...]
-
Page 15
Product specifications Displayed temperature range 93.2 °F -108 °F (34 °C - 42.2 °C) Operating ambient temperature range 50 °F -104 °F (10 °C - 40 °C) Display resolution 0.1 °F or °C Accuracy for patient temperature range Maximum Laborator y Er r or 96.8 °F -102.2 °F (36 °C - 39 °C): ± 0.4 °F ± 0.2 °C outside this range: ± 0.5 °[...]
-
Page 16
Service The Braun ThermoScan thermometer has a limited three year warranty . Should service be required during or after the warranty period, you must call Braun ThermoScan’ s Customer Service Department at 1-800-327-7226 to obtain a return authorization number and shipping address. Repackage the thermometer carefully in its original packaging or [...]