The rules should oblige the seller to give the purchaser an operating instrucion of Breckwell P2000I, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Breckwell P2000I one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Breckwell P2000I. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Breckwell P2000I should contain:
- informations concerning technical data of Breckwell P2000I
- name of the manufacturer and a year of construction of the Breckwell P2000I item
- rules of operation, control and maintenance of the Breckwell P2000I item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Breckwell P2000I alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Breckwell P2000I, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Breckwell service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Breckwell P2000I.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Breckwell P2000I item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
PROFESSIONAL INSTALLATION IS HIGHLY RECOMMENDED Manufactured by Breckwell Hearth Products Eugene, Oregon Arlington , Texas www.breckwell.com • Warning: If your a ppliance is not properly installed a house fire ma y result. For your safety , follow the installatio n directions. Contact local building or fire officials about rest rictions and inst [...]
-
Page 2
Thank you for purchasing the Breckwell Pellet Bu rning Stove. You are now prepared to burn wood in the most efficient, conv enient way possible. To achieve the safest, most efficient and most enjoyable performance from y our stove, you must do three th ings: 1) Install it properly; 2) Operate it correctly; and 3) Maintain it regularly. The purpose [...]
-
Page 3
Do not operate your stove if you smell smoke coming from it. Turn it off, monitor it, and call your dealer. Never try to repair or replace an y part of the stove unless instructions are given in this manual. All other work should be done by a trained technician. Never use gasoline, gaso line-type lantern fuel, kerosene, charcoal lighter fl uid, or [...]
-
Page 4
INTRODUCTION -------------------------------------------------------------------------------- ------------- 2 SAFETY PRECAUTIONS -------------------------------------------------------------------------------- -- 3 SPECIFICATIONS -------------------------------------------------------------------------------- ----------- 5 INSTALLATION ------------[...]
-
Page 5
FREESTANDING Width: 29 1/8” Height: 30 1/8” Depth: 22 5/8” Weight: 300 lbs. Flue size: 3” or 4” Hopper Capacity: Up to 70 lbs. (This can vary widely depending on pellet size, length, and diameter) EPA status: exempt Burn rate: 1 lb. to 5.5 lbs. per hour BTU range: 8,200 to 50,000 Approved installations: mobile home, alcove, conventional F[...]
-
Page 6
COMBUSTION AIR SUPPLY For a mobile home installation the stove must be connected to an outside source of combustion air. A 2” inside diameter metallic pipe, either flexible or rigid, may be attached to the inlet at the stove’s rear (refer to figures 5 & 6). A rod ent guard (minimum ¼” wire mesh)/wind hood must be used at the terminus (re[...]
-
Page 7
Equivalent Vent Length (EVL) The longer the run of pipe in your installation (both with insert and freestanding), the more restriction there is in the system. Therefore, larger diameter pipe should be used. • Use 4” pipe if you have more than 15 feet of Equi valent Vent Length. • Horizontal runs shall not exceed 10 feet of EVL. • Recommende[...]
-
Page 8
B. VERTICALLY WITH NEW CHIMNEY SYSTEM (Refer to Figure 9) NOTE: See “ VENTING ” and follow L-Vent chimney manufacturer’s instructions. OPTION: To ac hieve a center vertical installation a 45º elbow and a clean-out tee can be used to offset the pipe from the exhaust outlet to the rear center of the stove. OPTION: Install L-Vent elbo w in plac[...]
-
Page 9
D. VERTICALLY INTO EXISTIN G MASONRY FIREPLACE NOTE: See “ VENTING ” and follow L-Vent chimney manufacturer’s instructions. 1. Have the masonry chimney inspected by a qualified chimney sweep or installer to determine its structural condition. 2. You will need a pipe length equal to the chimney height from the hearth. If outside combustion air[...]
-
Page 10
INSERT INSTALLATIONS Insert installations must be vented with 3” or 4” pipe. Pipe may be single wall stainless steel flexible pipe. Vent may terminate within chimney beyond a blanking plate or extend to the chimney top. See “ COMBUSTIO N A IR SUPPLY ” for outside air access information. The fireplace and chimney should be cleaned thoroughly[...]
-
Page 11
B. WHEN VENT PIPE EXTENDS TO CHIMNEY TOP (Refer to Figure 15) 1. You will need a pipe length equal to the chimney height (from hearth) plus 6 inches. If outside combustion air is to be used, you will need a pipe length (see “ COMBUSTION A IR SUPPLY” ) equal to the chimney height plus 12 inches. 2. Attach cerablanket wrap to that end of vent pip[...]
-
Page 12
D. AS A BUILT-IN FIREPLACE Figures 16 and 17 describe a P2000 installation vented into either a special chase built outside an outer wall or a false inside wall. This is especially suited for ne w construction or remodeling. The equipment compartment (sides and rear of th e stove in fireplace) must be enclosed per the applicable electrical standard[...]
-
Page 13
E. INSTALLATION IN TO A F ACTORY BUILT (METAL) FIREPL ACE (refer to figure 18) When installing into a factory built fireplace, the firebox must accept the insert without modification other than removing bolted or screwed togethe r pieces such as smoke shelf/deflectors, ash lips, screen or door tracks and damper assemblies. These items must be reins[...]
-
Page 14
PANEL CONTROLS (See Figure 19) The blowers and automatic fuel supply are controll ed from a panel o n the left-hand si de of the P2000. The control panel functions are as follows. a. ON/OFF SWITCH • When pushed the stove will automatically ignite. No other firestarter is necessary. The igniter will stay on for at least 10 and up to 15 minutes, de[...]
-
Page 15
PROPER FUEL THIS STOVE IS APPROVED FOR BURNIN G PELLETIZED WOOD FUEL ONLY ! Factory-approved pellets are those ¼” or 5/16” in diameter and not over 1” long. Longer or thicker pellets some times bridge the auger flights, which prevents proper pellet feed. Burning wood in forms other than pellets is not permi tted. It will violate the building[...]
-
Page 16
RE-STARTING A WARM STOVE If the stove has been shut off, and you want to re-start it while it is still warm, the “on/off” button must be held do wn for 2 seconds. IF STOVE RUNS OUT OF PELLETS The fire goes out and the auger motor and blo wers will run unt il the stove cools. This will take 30 to 45 minutes. After the stove components stop runni[...]
-
Page 17
OPTIONAL THERMOSTA T A thermostat may help you maintain a constant house temperatu re automatically. A millivolt thermostat is required. A fixed wall mount or Breckwell’s hand held model c an be used. The control panel can be set up two ways to operate your stove in thermo stat mode. THERMOSTAT INSTALLATION • A MILLIVOLT THERMOST AT IS REQUIRED[...]
-
Page 18
OPERATING SAFETY PREC AUTIONS PLEASE READ THIS! a. Hot while in operation. Keep children, clothing, and furniture away. Contact may cause skin burns. b. If you notice a smoldering fire (burnpot full but no visible flame ) AND a heavy smoke buildup in firebox, immediately TURN OFF the stove, but DO NOT un plug it. Do not open the door, change the da[...]
-
Page 19
FAILURE TO CLEAN AND MAINTAIN TH IS UNIT AS INDICATED CAN RESUL T IN POOR PERFORMANCE AND SAFETY HAZARDS. NEVE R CLEAN WHEN HOT. NOTE: Inspect burn pot periodically to see that hol es have not become plugged, if so, clean thoroughly. ASH REMOVAL Ashes should be placed in a meta l container with a tight-fitting lid. The closed container or ashes sho[...]
-
Page 20
VACUUM USE If a vacuum is used to clean your unit, we suggest using a vacuum designed for ashes. (We recommend LoveLess Ash Vac, 1-800-568-3949 Ext. #27) Some regular vacuums and shop vacs leak ash into the room. Your vacuum or shop vac may have a special filter or bag available to eliminate this leakage. CLEANING a. Heat Exchange Tubes – Your Br[...]
-
Page 21
CHIMNEY CLEANING a. Creosote Formation – When any wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the rela tively cool chimney flue or a newly started fire or from a s low- burning fire. As a result, creosote residue accumulates on the flue lin[...]
-
Page 22
MAINTENAN C E 22 FIGURE 28 P2000I[...]
-
Page 23
When your stove acts out of the ordinary, the first reaction is to call for help. This guide may save time and money b y enablin g you to solve simple problems yourself. Problems can be c aused by to only five factors: 1) poor fuel; 2) poor operat ion or maintenance; 3) po or installation; 4) component failure; 5) factory defect. You can us ually s[...]
-
Page 24
STOVE SHUTS OFF AND THE # 3 LIGHT FLASHES Possible Causes: Possible Remedies: (Unplug stove first when possible) 1. The hopper is out of pellets. Refill the hopper. 2. The air damper is too far open f or a low feed setting. If burning on the low setting, you may need to close the damper all the way (push the knob in so it touches the side of the st[...]
-
Page 25
STOVE FEEDS PELLETS, BUT W ILL NOT IGNITE Possible Causes: Possible Remedies: 1. Air damper open too far for ignition. Push the air damper in closer to the side of the stove for startup. In some situations it may be necessary to have the damper completely closed for ignition to take place. After there is a flame, the damper can then be adjusted for[...]
-
Page 26
STOVE WILL NOT FEED PELLETS, BUT FUEL FEED LIGHT COMES ON AS DESIGNED Possible Causes : Possible Remedies: 1. Fuse on control board blew Remove the control board. On the back there is one fuse. If it appears to be bad, replace it with a 5 Amp 250 Volt fuse. Plug the stove back in and try to run the unit. 2. High limit switch has tripped or is defec[...]
-
Page 27
• GL AS S “S O O T’ S ” U P AT A VE R Y F AS T R AT E • FLAME IS LAZY, DARK, AND HAS BL ACK TIPS • AFTER STOVE HA S BEEN ON FOR A WHILE, THE BURNPOT OVERFILLS Possible Causes: Possible Remedies: 1. Stove or vent pipe is dirty, which restricts airflow through the burnpot. Follow all cleaning procedure in the maintenance section of the ow[...]
-
Page 28
HIGH LIMIT SWITCH KEEPS TRIPPING Possible Causes: Possible Remedies: 1. The convection blower is ov erheating and tripping the internal temperature shutoff. Clean any dust off of the windings and fan blades. If cleaning the blower does not help, it may be bad. 2. The stove is being left on the highest setting for extended periods of time. The highe[...]
-
Page 29
ELE C TRI C AL DIA G RAM FIGURE 29 2 9[...]
-
Page 30
Contact an Authorized Breckwell Pe llet Stove Dealer to obtain any of these parts. Never use substitute materials. Use of non-approved parts can result in poor performance and safety hazards. ITEM PART # Air Switch C-E-201 Air Switch Hose C-M-340-T Auger Motor C-E-017 Breckwell Maintenance Tool A-TOOL-96 Brick Panel Set, Ceramic – Optional A-M-BR[...]
-
Page 31
LIFETIME LIMITED WARRANTY Breckwell Hearth Products warrants to the original consumer purchaser that the Breckwell stove in its original installation is free from defects in material and workmanship from the original date of purchase as follows: Steel fabricated components, excluding burnpot inserts, are covered for five years. Glass an d burnpot i[...]