Briggs & Stratton 01917-0 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Briggs & Stratton 01917-0, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Briggs & Stratton 01917-0 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Briggs & Stratton 01917-0. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Briggs & Stratton 01917-0 should contain:
- informations concerning technical data of Briggs & Stratton 01917-0
- name of the manufacturer and a year of construction of the Briggs & Stratton 01917-0 item
- rules of operation, control and maintenance of the Briggs & Stratton 01917-0 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Briggs & Stratton 01917-0 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Briggs & Stratton 01917-0, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Briggs & Stratton service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Briggs & Stratton 01917-0.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Briggs & Stratton 01917-0 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Installation & Owner’s Manual Guide d'Installation et d'Utilisation Manual de Instalación y del Propietario Questions? Help is just a moment a wa y! Preguntas? La a yuda es justa un momento lejos! V ous a vez des questions? V ous n'a vez pas besoin d'aller loin pour tr ouver de l'aide! Call: T ransfer Switch Helpline[...]

  • Page 2

    2 Briggs & Stratton Po wer Pr oducts Automatic T ransfer Switch Installation and Owner’ s Manual T ABLE OF CONTENTS T ABLE OF CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 SAFETY R ULES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 INTR ODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . .[...]

  • Page 3

    3 Briggs & Stratton Po wer Pr oducts Automatic T ransfer Switch Installation and Owner’ s Manual SAFETY R ULES This is the safety alert symbol. It is used to alert you to potential personal injur y hazards. Obey all saf ety messages that f ollow this symbol to a void possible injury or death. The safety alert symbol ( ) is used with a signal [...]

  • Page 4

    4 Briggs & Stratton Po wer Pr oducts Automatic T ransfer Switch Installation and Owner’ s Manual INTR ODUCTION Thank you f or your pur chase of this Briggs & Stratton P ower Pr oducts Automatic T ransfer Switch. This pr oduct is intended for use with Briggs & Stratton Home Standby Generator sets ONL Y . This is an optional home standb[...]

  • Page 5

    5 Briggs & Stratton Po wer Pr oducts Automatic T ransfer Switch Installation and Owner’ s Manual Installer Responsibilities • Read and obser v e the safety rules. • Read and follow the instructions giv en in this manual. • Check federal, state and local codes. • Ensure generator is not o verloaded with selected loads. Equipment Descri[...]

  • Page 6

    6 Briggs & Stratton Po wer Pr oducts Automatic T ransfer Switch Installation and Owner’ s Manual ESSENTIAL CIRCUIT ISOLA TION Essential electrical loads are loads that will be po wer ed by the Home Generator System. Essential loads are gr ouped together and wired into the transf er switch. T O THE INST ALLER: Consult with Home Generator Syste[...]

  • Page 7

    7 Briggs & Stratton Po wer Pr oducts Automatic T ransfer Switch Installation and Owner’ s Manual Mounting Guidelines The Model 01917 Automatic T ransfer Switch is enclosed in a NEMA T ype 1 enclosur e suitable for indoor use only . The Model 01918 Automatic T ransfer Switch is enclosed in a NEMA T ype 3R enclosur e suitable for indoor/outdoor[...]

  • Page 8

    8 Briggs & Stratton Po wer Pr oducts Automatic T ransfer Switch Installation and Owner’ s Manual Generator Neutral is White wire Utility 240V AC GND lug Wire Nut T wo P ole Break er Utility Connection Generator Connection Rear of Control Panel Neutral Bus Neutral Bus Ground Bus Main Distribution Panel Automatic Po wer T ransfer Switch Home St[...]

  • Page 9

    9 Briggs & Stratton Po wer Pr oducts Automatic T ransfer Switch Installation and Owner’ s Manual SY STEM OPERA TION T o select automatic transfer operation, do the following: 1. Set circuit br eak er that sends utility power to transf er switch to “ On ” position. 2. Set generator’ s main cir cuit break er to its “ On ” position. 3.[...]

  • Page 10

    10 Briggs & Stratton Po wer Pr oducts Automatic T ransfer Switch Installation and Owner’ s Manual NO TES[...]

  • Page 11

    11 Briggs & Stratton Po wer Pr oducts Automatic T ransfer Switch Installation and Owner’ s Manual TR OUBLESHOO TING Pr oblem Cause Corr ection Automatic transfer switch does not transfer to generator 1. Generator break er open. 2. Generator voltage not acceptable. 1. Reset generator circuit br eak er . 2. Refer to generator manual. Automatic [...]

  • Page 12

    12 Briggs & Stratton Po wer Pr oducts Automatic T ransfer Switch Installation and Owner’ s Manual TRANSFER SWITCH SCHEMA TIC[...]

  • Page 13

    13 Briggs & Stratton Po wer Pr oducts Automatic T ransfer Switch Installation and Owner’ s Manual TRANSFER SWITCH WIRING DIA GRAM[...]

  • Page 14

    14 Briggs & Stratton Po wer Pr oducts Automatic T ransfer Switch Installation and Owner’ s Manual TRANSFER SWITCH EXPLODED VIEW & P AR TS LIST Item P art # Description 1 NSP LO ADCENTER 2 192909GS BO ARD , Contr ol 3 192151GS HOLDER, Fuse 4 190984GS DEC AL, Fuse 5 192597GS DEC AL, Utility , 240 V A C 6 193626GS T APTITE, #6 - 32 x 5/8&quo[...]

  • Page 15

    15 Briggs & Stratton Po wer Pr oducts Automatic T ransfer Switch Installation and Owner’ s Manual TRANSFER SWITCH EXPLODED VIEW & P AR TS LIST Item P art # Description 1 NSP LO ADCENTER 2 192909GS BO ARD , Contr ol 3 192151GS HOLDER, Fuse 4 190984GS DEC AL, Fuse 5 192597GS DEC AL, Utility , 240V A C 6 193626GS T APTITE, #6 - 32 x 5/8"[...]

  • Page 16

    16 Briggs & Stratton Po wer Pr oducts Automatic T ransfer Switch Installation and Owner’ s Manual NO TES[...]

  • Page 17

    BRIGGS & STRA TT ON POWER PRODUCTS GR OUP , LLC EQUIPMENT OWNER WARRANTY POLICY LIMITED W ARRANTY Briggs & S tratton Power Products Group, LLC will repair or replace, free of charge, any p art(s) of the equipment that is defective in material or workmanship or both. T ransportation charges on part s submitted for repair or replacement under[...]

  • Page 18

    18 Commutateur de transfert automatique Briggs & Stratton Po wer Pr oducts Guide d'installation et d'utilisation T ABLE DES MA TIÈRES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 RÈGLES DE SÉCURITÉ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 INTR ODUCTION . . . . . . . . . . . . . . .[...]

  • Page 19

    19 Commutateur de transfert automatique Briggs & Stratton Po wer Pr oducts Guide d'installation et d'utilisation DIRECTIVES DE SÉCURITÉ IMPOR T ANTES Ceci est la sûreté le symbole vif. Il est utilisé pour vous alerter aux dangers de blessur e personnels potentiels. Obéir tous messages de sûreté qui suivent ce symbole éviter l[...]

  • Page 20

    20 Commutateur de transfert automatique Briggs & Stratton Po wer Pr oducts Guide d'installation et d'utilisation INTRODUCTION Nous vous r emercions d'a voir acheté ce commutateur de transfert automatique de Briggs & Stratton Pow er Products (BSPP). Ce commutateur de transfert convient UNIQUEMENT aux génératrices de secours[...]

  • Page 21

    21 Commutateur de transfert automatique Briggs & Stratton Po wer Pr oducts Guide d'installation et d'utilisation Responsabilités de l'Installateur • V ous dev ez lire et r especter les règles de sécurité décrites dans le manuel. • V ous dev ez lire et suivr e les instructions indiquées dans le présent le manuel. • V?[...]

  • Page 22

    22 Commutateur de transfert automatique Briggs & Stratton Po wer Pr oducts Guide d'installation et d'utilisation ISOLA TION DES CIRCUITS ESSENTIELS Les charges électriques essentielles sont les charges qui seront alimentées par le groupe électr ogène. Les charges essentielles sont regr oupées et branchées au boîtier du commutat[...]

  • Page 23

    23 Commutateur de transfert automatique Briggs & Stratton Po wer Pr oducts Guide d'installation et d'utilisation Instructions d'installation Le modèle 01917 du commutateur de transfert automatique est contenu dans un boîtier de type NEMA 1, conçu pour une utilisation à l'intérieur seulement. Le modèle 01918 du commutat[...]

  • Page 24

    24 Commutateur de transfert automatique Briggs & Stratton Po wer Pr oducts Guide d'installation et d'utilisation Le câble blanc est le neutre de la génératrice Branchements des signaux de commande Languette de mise à la masse Serr e- fils Coupe-circuit à deux bornes Branchement de l'électricité de ser vice Branchement de l[...]

  • Page 25

    25 Commutateur de transfert automatique Briggs & Stratton Po wer Pr oducts Guide d'installation et d'utilisation FONCTIONNEMENT Pour actionner le transf er t automatique, suivez la procédur e décrite ci-dessous: 1. Réglez le disjoncteur qui transmet l'alimentation de ser vice au commutateur de transfert sur " On ". 2[...]

  • Page 26

    26 Conectador automático de Briggs & Stratton Po wer Pr oducts Manual de Instalación y del Pr opietario REMARQUES[...]

  • Page 27

    27 Conectador automático de Briggs & Stratton Po wer Pr oducts Manual de Instalación y del Pr opietario DÉP ANNA GE PROBLÈMES Le commutateur de transfert automatique ne transfère pas à la génératrice Le commutateur de transfert automatique ne transfère pas à l'alimentation de ser vice La génératrice continue de fonctionner apr?[...]

  • Page 28

    28 Commutateur de transfert automatique Briggs & Stratton Po wer Pr oducts Guide d'installation et d'utilisation REMARQUES[...]

  • Page 29

    GARANTIE DU PROPRIÉT AIRE D'UN PR ODUIT BRIGGS & STRA TTON PO WER PRODUCTS GROUP , LLC GARANTIE LIMITÉE Briggs & S tratton Power Products Group, LLC réparera ou remplacera, sans frais, toutes pièces d'équipement défectueuses comport ant un vice de matériau ou un défaut de fabrication ou les deux. En vertu de la présente g[...]

  • Page 30

    30 Conectador automático de Briggs & Stratton Po wer Pr oducts Manual de Instalación y del Pr opietario T ABLA DE CONTENIDO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 REGLAS DE SEGURID AD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 INTR ODUCCIÓN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [...]

  • Page 31

    31 Conectador automático de Briggs & Stratton Po wer Pr oducts Manual de Instalación y del Pr opietario INSTR UCCIONES IMPOR T ANTES DE SEGURID AD Éste es el símbolo de alerta de seguridad. Sir ve para advertir al usuario de un posible riesgo para su integridad física. Siga todos los mensajes de seguridad que figuren después de este símb[...]

  • Page 32

    32 Conectador automático de Briggs & Stratton Po wer Pr oducts Manual de Instalación y del Pr opietario INTRODUCCIÓN Muchas gracias por comprar un conectador automático de Briggs & Stratton. Este producto está pensado para utilizarlo como un sistema de reserva doméstico opcional que propor ciona una fuente alternativa de energía elé[...]

  • Page 33

    33 Conectador automático de Briggs & Stratton Po wer Pr oducts Manual de Instalación y del Pr opietario Responsabilidades del Instalador • Lea y obser ve las r eglas de seguridad que se encuentran en el manual. • Lea y siga las instrucciones que se encuentran en este manual. • Consulte toda la normativa nacional y local. • Asegúrese [...]

  • Page 34

    34 Conectador automático de Briggs & Stratton Po wer Pr oducts Manual de Instalación y del Pr opietario AISLAMIENT O DE LOS CIRCUIT OS FUND AMENT ALES Las cargas eléctricas fundamentales son aquellas que serán alimentadas mediante el Sistema de Generador Doméstico . Las cargas fundamentales se agrupan y se conectan dentro del compartimient[...]

  • Page 35

    35 Conectador automático de Briggs & Stratton Po wer Pr oducts Manual de Instalación y del Pr opietario Instrucciones de Montaje El conectador automático modelo 01917 está encerrado en una caja tipo 1 NEMA, que es adecuada para uso en interiores y a la intemperie. El conectador automático está encerrado en una caja tipo 3R según NEMA, qu[...]

  • Page 36

    36 Conectador automático de Briggs & Stratton Po wer Pr oducts Manual de Instalación y del Pr opietario Le câble blanc est le neutre de la génératrice Conexiones de señales de control Orejetas de conexión a tierra (GND) T uer ca para cable Interruptor bipolar Conexión de la compañía pro veedora de electricidad Conexión al generador P[...]

  • Page 37

    37 Conectador automático de Briggs & Stratton Po wer Pr oducts Manual de Instalación y del Pr opietario FUNCIONAMIENT O Para seleccionar el funcionamiento automático del conectador , haga lo siguiente: 1. Sitúe el interruptor que envía la tensión de la r ed pública al conectador en la posición " On " (conectado). 2. Ponga el d[...]

  • Page 38

    38 Conectador automático de Briggs & Stratton Po wer Pr oducts Manual de Instalación y del Pr opietario NO T AS[...]

  • Page 39

    39 Conectador automático de Briggs & Stratton Po wer Pr oducts Manual de Instalación y del Pr opietario REP ARA CION DE A VERIAS Prob lemo El conectador automático no transfiere la cone xión al generador El conectador automático no transfiere la cone xión a la red pública El generador sigue funcionando después de que el conectador trans[...]

  • Page 40

    Esperamos que disfrute de nuestra garantía y le pedimos disculpas por las molestias causadas. Cualquier distribuidor de servicio autorizado puede llevar a cabo reparaciones en garantía. La mayoría de las reparaciones en garantía se gestionan normalmente, pero algunas veces la solicitud de servicio en garantía puede no ser procedente. Por ejemp[...]