Go to page of
Similar user manuals
-
Smoke Alarm
BRK Electronic BRK Electronics
1 pages 26.38 mb -
Smoke Alarm
BRK electronic FG225
1 pages 0.88 mb -
Smoke Alarm
BRK electronic SC6120B
32 pages 0.8 mb -
Smoke Alarm
BRK electronic 4120 series
1 pages 1.98 mb -
Smoke Alarm
BRK electronic FIRST ALERT SCO7
1 pages 0.41 mb -
Smoke Alarm
BRK electronic 4120
2 pages 1.12 mb -
Smoke Alarm
BRK electronic SCO2B
2 pages 0.19 mb -
Smoke Alarm
BRK electronic SCO5RV
1 pages 2.06 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of BRK electronic M06-2016-007, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of BRK electronic M06-2016-007 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of BRK electronic M06-2016-007. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of BRK electronic M06-2016-007 should contain:
- informations concerning technical data of BRK electronic M06-2016-007
- name of the manufacturer and a year of construction of the BRK electronic M06-2016-007 item
- rules of operation, control and maintenance of the BRK electronic M06-2016-007 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of BRK electronic M06-2016-007 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of BRK electronic M06-2016-007, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the BRK electronic service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of BRK electronic M06-2016-007.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the BRK electronic M06-2016-007 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
• AC Powered Ionization Smoke Alarm with Battery Back-Up and Silence Featur e Cat. 4120SB Input: 120V AC, 60Hz, 0.5A AC Powered Ionization Smoke Alarm with Battery Back-up Cat. 4120B Input: 120V AC, 60Hz, 0.5A Model 4120B 4120SB M06-2016-007 06/00 User’ s Manual Smoke Alarms Ionization smoke alarms are generally more ef fective at detecting fl[...]
-
Page 2
INSIDE THIS MANUAL Where T o Install Smoke Alarms . . . . . . . . . 1 Where Not T o Install Smoke Alarms . . . . . . 3 Important! Read Before Y ou Install This Smoke Alarm . . . . . . . . . . . . . . . . . . . 5 Understanding the Indicator Lights and Alarm Horn Patter ns . . . . . . . . . . . . . . . . 6 Optional Locking Features . . . . . . . . . [...]
-
Page 3
1 Where T o Install Smoke Alarms Installing Smoke Alarms in Single-Family And Multi-Family Residences The National Fire Pr otection Association (NFP A), recommends one smoke alarm on every fl oor , in every sleeping ar ea, and in every bedroom. In new construction, the smoke alarms must be AC power ed and interconnected. See “Agency Placement Re[...]
-
Page 4
2 More specifically , install smoke alarms: • On every level of your home, including finished attics and basements. • Inside every bedroom, especially if people sleep with the door partly or completely closed. • In the hall near every sleeping area. If your home has multiple sleeping areas, install a unit in each. If a hall is more than 40 [...]
-
Page 5
3 reliable early warning protection for those areas separated by a door from the areas protected by the r equired smoke alarms. For this reason, it is recommended that the householder consider the use of additional smoke alarms for those areas for increased protection. The additional areas include the basement, bedrooms, dining room, furnace room, [...]
-
Page 6
4 Avoiding Dead Air Spaces “Dead air” spaces may prevent smoke from reaching the smoke alarm. T o avoid dead air spaces, follow the installation recommendations below . On ceilings, install smoke alarms as close to the center of the ceiling as possible. If this is not possible, install the smoke alarm at least 4 inches (102 mm) from the wall or[...]
-
Page 7
5 Important! Read Before Y ou Install This Smoke Alarm Read “Where T o Install Smoke Alarms” and “Where Not T o Install Smoke Alarms” befor e beginning. This unit monitors the air , and when smoke r eaches its sensing chamber , it alarms. It can give you mor e time to escape before fir e spreads. This unit can ONL Y give an early warning o[...]
-
Page 8
6 CAUTION ! Connect this unit ONL Y to other compatible units. See “How T o Install and Inter connect This Smoke Alarm” for details. Do not connect it to any other type of alarm or auxiliary device. Connecting anything else to this unit may damage it or pr event it fr om operating properly . CAUTION ! Do not stand too close to the unit when the[...]
-
Page 9
7 Important Installation Parts The Mounting Bracket : T o remove the mounting bracket from the smoke alarm base, hold the smoke alarm base firmly and twist the mounting bracket off. The mounting bracket installs onto the junction box. It has a variety of screw slots to fit most boxes. The Power Connector: The power connector plugs into a power in[...]
-
Page 10
8 T o Lock The Battery Compartment IMPORT ANT! Do not lock the battery compartment until you have activated the battery and tested the battery back-up. 1. Activate the battery back-up by removing the “Pull to Activate Battery Back-Up” tab. 2. Push and hold test button until the alarm sounds: 3 beeps, pause, 3 beeps, pause. If the unit does not [...]
-
Page 11
9 4. T o relock the battery compartment, close the battery door and reinsert locking pin in lock. 5. Reconnect the power connector to the back of the smoke alarm, reattach the smoke alarm to the mounting bracket, and restor e the power . IMPORT ANT! When replacing the battery , always test the smoke alarm before relocking the battery compartment. T[...]
-
Page 12
10 How T o Install This Smoke Alarm This unit is designed to be mounted on any standard wiring junction box up to a 4-inch diagonal size, on either the ceiling or wall. Read “Where to Install” and “Where Not T o Install” smoke alarms before you begin installation. If a junction box is not already in place, install one using standard #12 or [...]
-
Page 13
11 Installing a Single (Stand-Alone) Smoke Alarm T ools you will need: Standar d/Flathead screwdriver DANGER ! ELECTRICAL SHOCK HAZARD. T ur n off power to the area where you will install this unit at the circuit breaker or fuse box before beginning installation. Failure to turn off the power before installation may result in serious electrical sho[...]
-
Page 14
12 Interconnecting Multiple Smoke Alarms Interconnected units can pr ovide earlier warning of fire than stand-alone units, especially if a fir e starts in a remote ar ea of the dwelling. If any unit in the series senses smoke, all units will alarm. T o determine which smoke alarm initiated an alarm, see table: All wiring must conform to all local[...]
-
Page 15
13 Interconnecting Multiple Smoke Alarms T o install and interconnect multiple alarms: 1. Remove mounting bracket from the base. Position screw slots on mounting bracket over screws in the junction box. Tighten screws. 2. Strip off about 1/2” (12 mm) of the plastic coating on the orange wire on the power connector . 3. Using wire nuts, connect th[...]
-
Page 16
14 IMPORT ANT! Cat. 4120SB Only: During installation, if you accidentally press the Silence button, the alarm will “chirp” once a minute for up to 15 minutes and the T est featur e will be temporarily disabled. This is normal. The “chirping” will stop once the alarm returns to normal operation. T esting and Maintenance W eekly T esting W AR[...]
-
Page 17
15 IMPORT ANT! Most carbon zinc batteries have an average service life of 1 year; most alkaline batteries have an average service life of 1-2 years; most Lithium batteries have an average service life of 6-10 years. Actual service life depends on the smoke alarm and the environment in which it is installed. All the batteries specified above are ac[...]
-
Page 18
16 Cat. 4120SB Only— Using The Silence Feature The silence feature on this unit can temporarily quiet an unwanted alarm for several minutes. CAUTION ! The silence feature does not disable the unit—it makes it temporarily less sensitive to smoke. For your safety , if smoke ar ound the unit is dense enough to suggest a potentially dangerous situa[...]
-
Page 19
17 Protecting Y our Family From Fire Putting up smoke alarms is just one step in protecting your family fr om fires. Y ou must also reduce the chance a fir e will start in your dwelling, and have a plan for escaping safely if one does. T o have a good fire safety pr ogram, you must: Develop a family escape plan and practice it with everyone in y[...]
-
Page 20
18 What T o Do In Case Of Fire • Don’t panic; stay calm. Follow your escape plan. Y our safe escape may depend on thinking clearly and remembering what you have prac- ticed. • Get out of the dwelling as quickly as possible. Don’t stop to get dr essed or collect anything. • Feel doors with the back of your hand before opening them to see i[...]
-
Page 21
19 T roubleshooting DANGER ! ELECTRICAL SHOCK HAZARD. Always TURN OFF POWER before checking connections or disconnecting any smoke alarm! If you still have questions after reading this manual, please call Consumer Af fairs, Monday-Friday , 7:30 am-5pm (Central Time): 1-800-323-9005. Problem... Y ou should... Smoke alarm sounds when no smoke is visi[...]
-
Page 22
20 Special Compliance Considerations W ARNING! W ARNING! W ARNING ! This unit alone is not a suitable substitute for complete fi re detection systems in places housing many people—like apartment buildings, condominiums, hotels, motels, dormitories, hospitals, long-term health care facilities, nursing homes, day care facilities, or group homes of[...]
-
Page 23
21 Limitations Of Smoke Alarms Smoke alarms have played a key role in r educing deaths resulting fr om home fires worldwide. However , like any warning device, smoke alarms can only work if they are pr operly located, installed, and maintained, and if smoke reaches them. They ar e not foolpr oof. Smoke alarms cannot work without power . Battery op[...]
-
Page 24
22 10-Y EAR LIMITED W ARRANTY Coverage: BRK Brands, Inc. warrants its enclosed smoke alarm to be free from defects in materials and workmanship under normal use for a period of ten years from the date of purchase. During the first year after the date of purchase, BRK Brands, Inc. will replace any defective smoke alarm without char ge. During the n[...]