Go to page of
Similar user manuals
-
Ventilation Hood
Broan QP342BL
24 pages 2.84 mb -
Ventilation Hood
Broan QP130SSC
20 pages 1.56 mb -
Ventilation Hood
Broan K3139
36 pages 0.4 mb -
Ventilation Hood
Broan QTR050F
8 pages 5.79 mb -
Ventilation Hood
Broan 356NDK
2 pages 0.09 mb -
Ventilation Hood
Broan QP342WW
24 pages 2.84 mb -
Ventilation Hood
Broan 678MX
4 pages 0.59 mb -
Ventilation Hood
Broan QL130BC Ql100 Series
12 pages 4.06 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Broan P408ICAT, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Broan P408ICAT one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Broan P408ICAT. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Broan P408ICAT should contain:
- informations concerning technical data of Broan P408ICAT
- name of the manufacturer and a year of construction of the Broan P408ICAT item
- rules of operation, control and maintenance of the Broan P408ICAT item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Broan P408ICAT alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Broan P408ICAT, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Broan service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Broan P408ICAT.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Broan P408ICAT item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
E64000 SERIES INTENDED FOR DOMESTIC COOKING ONL Y INST ALLER: LEA VE THIS MANU AL WITH HOMEO WNER. HOMEO WNER: USE AND CARE INFORMA TION ON P A GES 13 AND 14. Broan-NuT one LLC; Har tf ord, Wisconsin www .broan.com 800-558-1711 Broan-NuT one Canada; Mississauga, Ontario www .broan.ca 877-896-1119 REGISTER Y OUR PRODUCT ON LINE A T : www .broan.com/[...]
-
Page 2
W ARNING W ARNING - 2 - T O REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJUR Y TO PERSONS, OBSER VE THE FOLLO WING: 1. Use this unit only in the manner intended by the manuf acturer . If you hav e questions, contact the manuf acturer at the address or telephone number listed in the warranty . 2. Bef ore ser vicing or cleaning unit, switch po wer of[...]
-
Page 3
HL0097 - 3 - RMP SERIES BA CKSPLASH (S T AINLESS S TEEL W ALL CO VERING WITH W ARMING SHEL VES . O PTIONAL .) 8” R OUND A DJUST ABLE E LBOW M ODEL 412 T RANSITION (3¼” X 10” TO 7”) A DAPTER /D AMPER 3¼’ ’ X 10’ ’ ( SUPPLIED WITH SINGLE BLOWER HOOD ) A DAPTER 4½” X 18½” ( SUPPLIED WITH DOUBLE BLOWER HOOD ) S T AND ARD D UCT ([...]
-
Page 4
- 4 - HL009 8 RMP SERIES BA CKSPLASH (S T AINLESS S TEEL W ALL CO VERING WITH W ARMING SHEL VES . O PTIONAL ) E64000 SERIES HOOD - E64000 SERIES RANGE HOOD SYSTEM - IN-LINE AND EXTERIOR BLO WERS 332KR IN - LINE AND E XTERIOR B LOWER R OUGH - IN K IT ( SUPPLIED WITH HOOD ) M ODEL 418 10” R OUND A DJUST ABLE E LBOW M ODEL HLB3 (280 CFM ) I N - LINE[...]
-
Page 5
- 5 - 1. SELECT BLOWER OPTION AND INST ALLA TION TYPE 1.2 D UCTED I NST ALLA TION The Broan Elite E64000 Series range hood includes many configurations: hood with single or double internal blow ers (included with the hood), or hood using e xter nal blo wers. For hood using e xter nal blo wers, the Broan Elite E64000 Series must be installed with in[...]
-
Page 6
- 6 - 2. PREP ARE THE INST ALLA TION Make sure that the f ollowing items are included: - Range hood - Accessories: • Baffle filters • Baffle filters handles (located inside the hood) • 3¼” x 10” adapter/damper (located inside inter nal single blo wer hood) • 4½” x 18½” adapter (screwed inside internal double b lower hood) • In-[...]
-
Page 7
- 7 - 2. PREP ARE THE INST ALLA TION (CONT’D) Cut-out the openings f or duct ( A ) and power cab le ( B ), in cabinet or wall, according to the direction of discharge chosen. See figures below . NO TE: F or all inter nal blo wer hoods, the cut-out opening f or house wiring can be made in cabinet bottom OR wall, no matter the discharge chosen (ver[...]
-
Page 8
- 8 - 4. REMOVE FIL T ERS AND GREASE DRIP RAIL A. Remov e tape on filters. Remov e filters from hood and set aside. NO TE: It is recommended to star t with the center one(s). B. Remov e tape on grease drip rail ( 1 ). Lift out grease drip rail and set aside. HD0240 1 5. REMOVE THE ADAPTER (INTERNAL BLOWER HOODS ONL Y) Remov e both screws retaining [...]
-
Page 9
- 9 - 6. CHOOSE THE OPENING(S) (INTERNAL BLOWER HOODS ONL Y) Remov e the knock out for the chosen opening(s) (horizontal at the bac k of the hood or vertical on top). See illustrations below . V ERTICAL DISCHARGE H ORIZONT AL DISCHARGE NO TE: F or ducted installation only . 1 2 3 HR0021 1 2 3 Punch out the appropriate electr ical knoc kout hole on [...]
-
Page 10
- 10 - 7. HORIZONT AL DISCHARGE INST ALLA TION ( INTERNAL BLOWER(S) ONL Y) HD0271 Flip the blo wer and engage its flange in the back w all retaining brac ket. Using a 5/16” sock et and the screws pre viously remov ed, secure the blo wer to the hood. HD0272 8. INST ALL THE ADAPTER AND THE TRANSITION (IF NEED BE) (INTERNAL BLOWER HOOD ONL Y) Using [...]
-
Page 11
- 11 - 10. INST ALL THE HOOD (ALL BLOWERS) HD0265 A B A B B INTERNAL BLO WER: Run power cab le to installation location. Place the hood in its location. Mar k the position of the scre ws (smaller par t of the ke y holes [ A ]) with a pen. Remov e the hood and install the (4) 1/2” doub le thread screws at marked positions , leaving a 1/8” gap. R[...]
-
Page 12
- 12 - 13. INST ALL LIGHT BULBS This hood must use 120 V , 50 W , MR16 with GU10 base or P AR16 with GU10 base, shielded halogen lamps (not included). W ARNING In order to pre vent the risk of personal injury , do not install a lamp identified f or use only in enc losed fixtures. ! W ARNING In order to pre vent the risk of personal injury , the hal[...]
-
Page 13
- 13 - 15. USE AND CARE Baffle Filters The baffle filters should be cleaned frequently . Use a war m detergent solution. W ash more often if your cooking style generates greater grease—lik e fr ying foods or w ok cooking. Remov e baffle filters by pushing them to wards the back of hood and rotating filters do wnward. Baffle filters are dishwasher[...]
-
Page 14
- 14 - 16. OPERA TION (CONT’D) HC00 3 5 1) Halogen light knob 2) Blower operation indicator 3) ON/OFF blow er switch 4) Blower speed control knob 2 3 1 4 HC00 3 4 A) Halogen light knob B) Blower speed control knob A B COOKT OP LIGHTING (HALOGEN) A rotar y 3-position knob ( 1 ) controls the halogen lights (OFF - low intensity - high intensity). BL[...]
-
Page 15
- 15 - 18. WIRING DIAGRAMS Broan Elite E64000 Series Internal blower hoods Broan Elite E64000 Series Exterior or In-Line blower hoods LINE NEUTRAL GROUND 120 V AC WHT M BRN BLU RED BLK M BRN BLU RED BLK WHT S PEED CONTROL H S THERMO S TAT BLU BLK BLK BLU BLK YEL WHT WHT WHT WHT WHT BLK BLK YEL YEL BLK ORA NEON LAMP ORA LAMP S WITCH L 1- 3 2 FAN S W[...]
-
Page 16
- 16 - 19. SER VICE P ARTS HL0104 Broan Elite E64000 Series Internal blower hoods Broan Elite E64000 Series Exterior or In-Line blower hoods 6 7 14 17 * N OT SHO WN . K EY NO . P ART NO . D ESCRIPTION Q TY . ( H OOD WIDTH ) 30” 36” 42” 48” 2 SV06750 B ROAN E LITE L OGO 1 1 1 1 3 SV16569 L AMP S HELL , S OCKET & T RIM A SS ’ Y 2 2 3 3 [...]