Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV should contain:
- informations concerning technical data of Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV
- name of the manufacturer and a year of construction of the Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV item
- rules of operation, control and maintenance of the Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bryant service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    352AAV 4-Way Multipoise Two-Stage Condensing Gas Furnace Sizes 060 thru 120 Product Data A05085 Utilizing the extensive resources available to Bryant, a new stan- dard of excellence has been achieved with the model 352AAV Plus 90t TM 4-Way Multipoise Furnace. The model 352AAV is a unique 4-way multipoise condensing fur- nace with features like no o[...]

  • Page 2

    —2— 352AAV A05070 NO TE S : 1. Minim u m ret u rn- a ir opening s a t f u rn a ce, bas ed on met a l d u ct. If fle x d u ct i s us ed, s ee flex d u ct m a n u f a ct u rerí s recommend a tion s f or e qu iv a lent di a meter s . 2. Minim u m ret u rn - a ir opening a t f u rn a ce: a . For 800 CFM–16-in. ro u nd or 14 1 / 2 x 12-in. rect a[...]

  • Page 3

    —3— 352AAV Non-Programmable Thermostat Selection * Model HP and 2S thermostat must be field converted to air conditioner operation. **Thermidistat Control is versatile and can be configured for multiple use and staging, it must be configured for each specific application. Programmable Thermostat Selection * Model HP and 2S thermostat must be fi[...]

  • Page 4

    —4— 352AAV SPECIFICATIONS See notes on page 5. UNIT SIZE 036060 036080 048080 048100 060100 060120 RATINGS AND PERFORMANCE Input Btuh† Low 39,000 52,000 52,000 65,000 65,000 7 8 ,000 High 60,000 8 0,000 8 0,000 100,000 100,000 120,000 Output Capacity BTUH* (ICS) Direct Vent (2-Pipe) Low Upflow 37,000 49,000 49,000 61,000 61,000 74,000 (Shaded[...]

  • Page 5

    —5— 352AAV SPECIFICATIONS Continued * Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 2% for each 1000 ft above sea level. In Canada, derate the unit 5% from 2000 to 4500 ft above sea level. † Capacity and AFUE in accordance with U.S. Government DOE test procedures effective November 10,[...]

  • Page 6

    —6— 352AAV COMBUSTION-AIR AND VENT PIPING FOR DIRECT VENT (2-PIPE) AND NON-DIRECT VENT (1-PIPE) APPLICATIONS MAXIMUM ALLOWABLE PIPE LENGTH (FT) ALTITUDE (FT) UNIT MAX INPUT RATE (BTUH) DIRECT VENT (2-PIPE) ONLY NON-DIRECT VENT (1-PIPE) ONLY NUMBER OF 90° ELBOWS TERMINATION TYPE PIPE DIA (IN.)* PIPE DIA (IN.)* 1 23456 0 to 2000 60,000 2 Pipe or[...]

  • Page 7

    —7— 352AAV MAXIMUM ALLOWABLE PIPE LENGTH (FT) (CONTINUED) ALTITUDE (FT) UNIT MAX INPUT RATE (BTUH) DIRECT VENT (2-PIPE) ONLY NON-DIRECT VENT (1-PIPE) ONLY NUMBER OF 90° ELBOWS TERMINATION TYPE PIPE DIA (IN.)* PIPE DIA (IN.)* 12 3 4 5 6 4001 to 5000‡ 60,000 2 Pipe or 2-in Concentric 1-1/2 1-1/2 15 10 5 NA NA NA 2 2 64 59 58 5 3 52 52 80,000 2[...]

  • Page 8

    — 8 — 352AAV COMBUSTION-AIR AND VENT PIPING FOR DIRECT VENT (2-PIPE) AND NON-DIRECT VENT (1-PIPE) APPLICATIONS continued MAXIMUM ALLOWABLE PIPE LENGTH (FT) (CONTINUED) ALTITUDE (FT) UNIT SIZE (BTUH) DIRECT VENT (2-PIPE) ONLY NON-DIRECT VENT (1-PIPE) ONLY NUMBER OF 90° ELBOWS TERMINATION TYPE PIPE DIA (IN.)* PIPE DIA (IN.)* 1 23456 7001 to 8000[...]

  • Page 9

    —9— 352AAV MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH (FT) WITH AND WITHOUT INSULATION IN WINTER DESIGN TEMPERATURE AMBIENT * * Pipe length (ft) specified f or maximum pipe lengths located in unconditioned spaces. Pipes located in unconditioned space cannot exceed total allowab le pipe length as specified in T able 6. † Insulation thickness[...]

  • Page 10

    —1 0— 352AAV CONDENSATE TRAP A93026 1 ⁄ 2 OD INDUCER HOUSING DRAIN CONNECTION 1 ⁄ 4 OD COLLECTOR BOX TO TRAP RELIEF PORT 5 ⁄ 8 OD COLLECTOR BOX DRAIN CONNECTION 1 ⁄ 2 -IN. PVC OR CPVC SCREW HOLE FOR UPFLOW OR DOWN- FLOW APPLICATIONS (OPTIONAL) 1 4 2 7 8 1 8 7 SLOT FOR SCREW HORIZONTAL APPLICATION (OPTIONAL) WIRE TIE GUIDES (WHEN USED) 1[...]

  • Page 11

    —1 1— 352AAV ACCESSORIES CONCENTRIC VENT FOR DIRECT VENT (2-PIPE) APPLICATION (ALL MODEL SIZES) A97110 DIMENSIONS (In.) * Dimension A will change accordingly as dimension D is lengthened or shortened. †Dimension D may be lengthened to 60 in. maximum. Dimension D may also be shortened by cutting the pipes provided in the kit to 12 in. minimum.[...]

  • Page 12

    —1 2— 352AAV AIR DELIVERY—CFM (With Filter) • Airflow shown is with factory supplied 1-in. washable filter. • A filter is required for each return air opening. • An airflow reduction of up to 7% may occur when using the factory-specified 4-5/16-inch wide, high efficiency media filter. • For best furnace efficiency when using the 4 5/1[...]

  • Page 13

    —1 3— 352AAV ELECTRONIC AIR CLEANER HUMIDIFIER A/C COIL VENT COMBU S TION AIR (DIRECT VENT/ 2 PIPE APPLICATION OUTDOOR UNIT AIRFLOW FRONT OF FURNACE A05065 COMBU S TION AIR INLET (NON-DIRECT VENT/ 1-PIPE APPLICATION COMBU S TION AIR PIPE (DIRECT VENT/2-PIPE APPLICATION) A/C COIL OUTDOOR UNIT VENT PIPE HUMIDIFIER GA S -FIRED WATER HEATER ELECTRO[...]

  • Page 14

    —1 4— 352AAV COMBU S TION–AIR PIPE ELECTRONIC AIR CLEANER FURNACE CONDEN S ATE DRAIN REFRIGERATION PIPING AIR CONDITIONING COIL AIRFLOW VENT PIPE FRONT OF FURNACE A05066 DIRECT VENT/2-PIPE APPLICATION) COMBU S TION-AIR INLET (NON-DIRECT VENT/1-PIPE APPLICATION) COMBU S TION– AIR PIPE (DIRECT VENT/2-PIPE APPLICATION) VENT PIPE ELECTRONIC AIR[...]

  • Page 15

    —1 5— 352AAV[...]

  • Page 16

    — 16 — ©Bryant Heating & Cooling systems 7310 W. Morris St. Indianapolis, IN 46231 Printed in U.S.A. edition date: 09/09 Catalog No. PDS 352A.60.2 352a.60.1 Rev.A S D P : s e c a l p e R s n o i t a g i l b o d n a e c i t o n t u o h t i w s n g i s e d r o s n o i t a c i f i c e p s , e m i t y n a t a , e g n a h c o t t h g i r e h t [...]