Go to page of
Similar user manuals
-
Air Conditioner
Bryant 533A
24 pages 0.14 mb -
Air Conditioner
Bryant 577D
8 pages 0.95 mb -
Air Conditioner
Bryant 450D
10 pages 0.71 mb -
Air Conditioner
Bryant 704B
4 pages 0.23 mb -
Air Conditioner
Bryant 585E
16 pages 1.58 mb -
Air Conditioner
Bryant OM11-19
8 pages 0.31 mb -
Air Conditioner
Bryant ELECTRIC AIR CONDITIONER 561C
28 pages 2.27 mb -
Air Conditioner
Bryant 585B/YACR
15 pages 3.09 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Bryant 619MNQ, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bryant 619MNQ one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Bryant 619MNQ. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Bryant 619MNQ should contain:
- informations concerning technical data of Bryant 619MNQ
- name of the manufacturer and a year of construction of the Bryant 619MNQ item
- rules of operation, control and maintenance of the Bryant 619MNQ item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bryant 619MNQ alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bryant 619MNQ, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bryant service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bryant 619MNQ.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Bryant 619MNQ item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Owne r ’ s Manual 538MAC / 619MAC, 538MAQ / 619MAQ SIZES 009 - - 012 538MNC / 619MNC, 538MNQ / 619MNQ SIZES 012 - - 024 HIGH - - W ALL DUCT - - F REE SPLIT S YSTEM T ABLE OF CONTENTS P AGE SAFETY PRECAUTIONS 2 ..................................................................................... GENERAL 2 ..........................................[...]
-
Page 2
2 SAF ETY PRECAUTIONS PERSONAL INJURY , DEA TH, OR PROPERTY DAMAGE HAZARD Fai l ur e t o f ol low thi s war ning coul d r e sul t i n per s ona l inj ur y , dea th, or prope r ty dam a ge. Rea d and fol l ow a ll i ns tr uc t ions and war nings , inc l uding la be l s shi ppe d wit h or at t a c hed t o unit befor e ope r a ti ng your new a ir c on[...]
-
Page 3
3 P AR T NAMES Air outlet Air outlet Air inlet Air inlet 3 11 12 13 8 7 4 5 6 9 21 Front panel frame Front panel Air filter Horizontal air flow grille V ertical air flow louver Room temperature sensor Display panel Infrared signal receiver Remote control Interconnecting tubing Control and power wiring to indoor unit Service valves 1 3 4 5 6 7 8 9 1[...]
-
Page 4
4 UNIT DISPLA Y P ANELS NOTE: The dis pl ay panel on the indoor uni t wil l l ook like one of t he fol l owing. Some of the f unc t ions wi l l appear on the di s play panel , r emot e cont r ol or both. On the Unit: Infrared signal receptor OPERA TION TIMER PRE-DEF AUTO ECON A08486 9K TIMER OPERA TION PRE-DEF Infrared signal recepto r A07544 12K T[...]
-
Page 5
5 REMOTE CONTROL MOD E FAN S P E E D TEMP . AI R DIRE CTION SWI N G LED SLEEP TURB O CLOCK TI MER CAN CEL RE SE T F/C AUT O C OO L DR Y HE AT FA N SE T TE MP. CL OC K TIM ER ON TIM ER OF F SPE ED AUTO L OW MED HIGH ON OFF A08032 EQUIPMENT DAM AGE HAZARD Failu re to follo w t his cau tion m ay result in eq u ipm ent dam a ge. Han dle the con tro l w[...]
-
Page 6
6 Remote Control Operation - - Quick Start NOTE: Wh en tran smittin g a com man d fro m t he rem ote co ntro l to the uni t , be sur e t o point the c ont r ol towa rd the ri ght si de of t he un it. the u nit w ill co nfirm receip t o f a comm and b y s ounding a n audi bl e be e p. 1. Tur n the unit on by pus hi ng the ON/OFF butt on. 2. If t he [...]
-
Page 7
7 Sele c ting t he Fan Sp eed SET TEMP. C L O C K SPEED AU TO AUTO LOW MED HIGH A08036 Th e fan speed can b e selected b y p ressing th e F AN SPEED button. NOTE: Whe n t he uni t is on, the fa n wil l run c onti nuous l y in coo lin g or heatin g. Wh en in h eating , there migh t be situation s whe re the fa n wi ll sl ow down or shut of f t o pr [...]
-
Page 8
8 Tim er O N an d Tim er OFF SET TEMP. C L O C K SPEED AUTO AUTO TIMER OFF TIMER ON A08041 Us e bot h f unc ti ons to pr ogr a m t he uni t to t ur n on and shut of f at specified tim es. UNIT OFF - - Set TI MER ON as pr e vious l y des c ri be d. - - Set TI MER OFF as pr e vious l y des cr i be d. - - T he u nit w ill start auto matically at the s[...]
-
Page 9
9 CLEANING, MAI NTENANCE AND TROUBLESHOOTING ELECTRICAL SHOCK HAZARD Failu re to follow th is caution m ay result in p erson al injury or dea th. Alw a ys t ur n of f powe r t o t he sys te m befor e per f orm ing a ny cl e a ni ng or mai nte na nc e t o the s yste m. Tur n of f the outdoor dis c onne c t sw it c h loc at e d nea r out door unit . [...]
-
Page 10
10 T able 1— Pe ri odi c Mai nte nanc e INDOOR UNIT EVERY MON TH EVERY 6 MON THS EVERY YEAR Clean Air Fil ter* Ch ang e Remote C ontrol Ba tteries S S S OUTDOOR U NIT EVERY MON TH EVERY 6 MON THS EVERY YEAR Clean Ou tdoor C oil from Outsid e Clean Outd oor C oil from Inside † B l o wA i rO v e rE l e c t r i cP a r t s † Ch eck Electr ic Con [...]