Go to page of
Similar user manuals
-
Furnace
Bryant 350MAV
16 pages 0.25 mb -
Furnace
Bryant 394B
6 pages 0.96 mb -
Furnace
Bryant 396D
4 pages 1.49 mb -
Furnace
Bryant PLUS 90X 353AAV
22 pages 3.38 mb -
Furnace
Bryant 345MAV
40 pages 0.49 mb -
Furnace
Bryant SERIES D 393U
2 pages 3.38 mb -
Furnace
Bryant 310
8 pages 0.84 mb -
Furnace
Bryant 364AAN
16 pages 0.73 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Bryant CK3B, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bryant CK3B one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Bryant CK3B. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Bryant CK3B should contain:
- informations concerning technical data of Bryant CK3B
- name of the manufacturer and a year of construction of the Bryant CK3B item
- rules of operation, control and maintenance of the Bryant CK3B item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bryant CK3B alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bryant CK3B, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bryant service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bryant CK3B.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Bryant CK3B item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Form No. PDS CK3B.24.2 Cased Horizontal Furnace Coil CK3B Sizes A024 thru A060 This horizontal N-Coil is designed to provide the highest standard of reliability and durability. The CK3B coil casing is unpainted embossed galvanized steel. The cabinet is fully insulated to minimize energy loss. The CK3B is designed for application with horizontal fur[...]
-
Page 2
—2— MODEL NUMBER NOMENCLATURE CK 3 C—Coil K—Cased, N-Coil 3—Horizontal 5—Upflow/Downflow CERTIFICATION APPLIES ONLY WHEN USED WITH PROPER COMPONENTS AS LISTED WITH ARI BXA 0 2 4 024—2 Ton 030—2-1/2 Ton 036—3 Ton 042—3-1/2 Ton 048—4 Ton 060—5 Ton A—Standard N—Narrow W—Wide X—Max. Cap. Position A—Painted B—Embossed[...]
-
Page 3
—3— A97521 DIMENSIONS (In.) UNIT ABCDE SHIPPING WEIGHT In. In. In. In. In. Lb CK3BXA024 17-9/16 19-1/16 10-1/16 5/8 16 36.0 CK3BXA030 17-9/16 19-1/16 10-1/16 3/4 16 39.5 CK3BXA036 17-9/16 22-1/16 10-1/4 3/4 16 45.5 CK3BXA042 21-1/16 22-1/16 10-1/4 7/8 19-1/2 47.0 CK3BXA048 21-1/16 22-1/16 10-1/4 7/8 19-1/2 51.0 CK3BXA060 24-9/16 28-1/8 13-3/6 7[...]
-
Page 4
—4— COOLING CAPACITIES (MBH) See notes on page 5. UNIT SIZE INDOOR COIL AIR SATURATED TEMPERATURE LEAVING EVAPORATOR ( ° F) 30 35 40 45 50 CFM EWB TC SHC BF TC SHC BF TC SHC BF TC SHC BF TC SHC BF A024 600 72 38.7 17.9 0.00 35.4 16.4 0.00 32.0 15.0 0.13 28.1 13.3 0.08 23.7 11.6 0.07 67 32.6 19.5 0.07 29.1 17.9 0.06 25.6 16.3 0.06 21.5 14.5 0.0[...]
-
Page 5
—5— CFM — Cubic Ft per Minute EWB — Entering Wet Bulb ( ° F) LWB — Leaving Wet Bulb ( ° F) TC — Total Cooling Capacity 1000 Btuh SHC — Total Sensible Capacity 1000 Btuh BF — Bypass Factor MBH — 1000 Btuh NO TES: 1. Contact manuf acturer for cooling capacities at conditions other than shown in tab le. 2. Formulas: Leaving db = en[...]
-
Page 6
—6— TYPICAL N-COIL HORIZONTAL INSTALLATIONS Horizontal Left FILLER PLATE N-COIL AIRFLOW FURNACE DRAIN CONNECTION A97203 FILLER PLATE N-COIL AIRFLOW FURNACE DRAIN CONNECTION Horizontal Right A97037[...]
-
Page 7
—7—[...]
-
Page 8
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS Cancels: PDS CK3B.24.1B © 1997 Bryant Heating & Cooling Systems, 7310 W. Morris St., Indpls., IN 46231 —8— PRINTED IN U.S.A. Catalog No. 12CK-3B0 9-97 SERVICE TRAINING Packaged Service Training programs are an excellent way t[...]