A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Bryant R-22 561G, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bryant R-22 561G one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Bryant R-22 561G. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Bryant R-22 561G should contain:
- informations concerning technical data of Bryant R-22 561G
- name of the manufacturer and a year of construction of the Bryant R-22 561G item
- rules of operation, control and maintenance of the Bryant R-22 561G item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bryant R-22 561G alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bryant R-22 561G, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bryant service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bryant R-22 561G.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Bryant R-22 561G item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    NOTE: Read the entire instruction manual before starting the installation. This symbol → indicates a change since the last issue. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause death, personal injury, or property dam[...]

  • Page 2

    II. INSTALL ON A SOLID, LEVEL MOUNTING PAD If conditions or local codes require the unit be attached to pad, tie-down bolts should be used and fastened through knockouts provided in unit base pan. Refer to unit-mounting pattern in Fig. 3 to determine base-pan size and knockout-hole location. Arrange supporting members to adequately support unit and[...]

  • Page 3

    CAUTION: UNIT DAMAGE HAZARD Failure to follow this caution may result in unit compo- nent damage. To avoid equipment damage and/or loss of performance remove indoor-coil piston if unit is to be installed on system with a TXV-metering device. Check outdoor unit piston. Remove retainer on liquid service valve and check piston size with matching numbe[...]

  • Page 4

    Use furnace transformer, fan-coil transformer, or accessory trans- former for control power, 24v/40va minimum. NOTE: Use of available 24v accessories may exceed the mini- mum 40va power requirement. Determine total transformer load- ing and increase the transformer capacity or split the load with an accessory transformer as required. IX. COMPRESSOR[...]

  • Page 5

    B. Cooling Only Procedure—Indoor unit equipped with TXV—Subcooling Method Factory charge and subcooling are shown on unit information plate. To check charge, follow the procedure below. NOTE: If subcooling charging conditions are not favorable, charge must be weighed in accordance with unit rating plate, ±0.6 oz/ft. of 3/8-in. liquid line abov[...]

  • Page 6

    © 2006 Bryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231 —6— Printed in U.S.A. Catalog No. II 561G-30-1[...]