Bryant TEMPSURE COMMERCIAL THERMOSTAT P/N TSTATBBP220-LA manual

1
2
3
4
5
6
7
8

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Bryant TEMPSURE COMMERCIAL THERMOSTAT P/N TSTATBBP220-LA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bryant TEMPSURE COMMERCIAL THERMOSTAT P/N TSTATBBP220-LA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Bryant TEMPSURE COMMERCIAL THERMOSTAT P/N TSTATBBP220-LA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Bryant TEMPSURE COMMERCIAL THERMOSTAT P/N TSTATBBP220-LA should contain:
- informations concerning technical data of Bryant TEMPSURE COMMERCIAL THERMOSTAT P/N TSTATBBP220-LA
- name of the manufacturer and a year of construction of the Bryant TEMPSURE COMMERCIAL THERMOSTAT P/N TSTATBBP220-LA item
- rules of operation, control and maintenance of the Bryant TEMPSURE COMMERCIAL THERMOSTAT P/N TSTATBBP220-LA item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bryant TEMPSURE COMMERCIAL THERMOSTAT P/N TSTATBBP220-LA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bryant TEMPSURE COMMERCIAL THERMOSTAT P/N TSTATBBP220-LA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bryant service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bryant TEMPSURE COMMERCIAL THERMOSTAT P/N TSTATBBP220-LA.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Bryant TEMPSURE COMMERCIAL THERMOSTAT P/N TSTATBBP220-LA item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    CONTENTS Page SAFETY CONSIDERA TIONS ...................... 1 GENERAL ..................................... 1 INST ALLA TION ................................ 1 - 6 I. Select Thermostat Location ................ 1 II. Install Thermostat ........................ 2 III. Set Clock ................................ 3 IV . Heat Pump Configuration .......[...]

  • Page 2

    II. INST ALL THERMOST A T W ARNING: Before installing thermostat, turn of f all power to the unit. There may be more than one power disconnect. Electrical shock can cause injury or death. 1. T urn of f all power to unit. 2. If an existing thermostat is being replaced: a. Remove existing thermostat from the wall. b. Disconnect wires from existing th[...]

  • Page 3

    T able 1 — Thermostat Wiring T erminations EXISTING WIRE DESIGNA TION FUNCTION TERMINAL CONNECTION Go rF Fan G Y1, Y , or C Cooling Y1 W1, W , or H Heating W1/O/B Rh, R, M, V r, or A Power (24 v) R C Common C* O/B Reversing V alve W1/O/B† Y2 Second Stage Cooling Y2* W2 Second Stage Heating W2* *T erminals C, W2, and Y2 may not be used in all ap[...]

  • Page 4

    B. Electric Heat Configuration (Step 5) Step 5 is used to configure the thermostat for electric heat. The variable can be configured ON or OFF . The default is OFF . NOTE: Step 5 will appear only if Step 3 is set to OFF . C. Deadband (Step 6) The deadband is the dif ference in temperature above the cooling set point or below the heating set poin[...]

  • Page 5

    T able 3 — Daily Schedule Planner DA Y OF THE WEEK SCHEDULE Occupied 1 Occupied 2 Occupied 3 Unoccupied Start / Stop / Heat / Cool Start / Stop / Heat / Cool Start / Stop / Heat / Cool Heat / Cool Monday /// /// /// / T uesday /// /// /// / Wednesday /// /// /// / Thursday /// /// /// / Friday /// /// /// / Saturday /// /// /// / Sunday /// /// /[...]

  • Page 6

    12. After all the times and set points for each day have been entered, press the Program button to exit pro- gramming mode. NOTE: The thermostat will continue to follow the schedule until a new one is entered. If only one occupied schedule is selected, the Occupied 2 and 3 schedules are skipped. If the start time is set later in the day than the st[...]

  • Page 7

    OPERA TION The Mode button selects the operating mode of the thermo- stat. If OFF is selected, the thermostat will not enter Heat- ing or Cooling mode. If HEA T is selected, the thermostat will only enter Heating mode (if the room temperature is below the heating set point). If COOL is selected, the thermostat will only enter Cooling mode (if the r[...]

  • Page 8

    TROUBLESHOOTING T able 4 — Thermostat T roubleshooting PROBLEM SOLUTION Display on thermostat not illuminated. Check for 24 vac at the R terminal connection. T erminal R must be connected for proper thermostat operation. ‘ ‘Service Filter ’ ’ is displayed on thermostat. After the configured number of blower operating hours, the Service F[...]