Go to page of
Similar user manuals
-
Thermostat
Bryant PSPHA732
16 pages 0.68 mb -
Thermostat
Bryant A07049
84 pages 2.18 mb -
Thermostat
Bryant TSTAT
8 pages 0.06 mb -
Thermostat
Bryant T6-PHP01A
60 pages 1.87 mb -
Thermostat
Bryant TSTATBBPRF01-B
22 pages 0.7 mb -
Thermostat
Bryant T6-PHP
64 pages 1.83 mb -
Thermostat
Bryant P/N TSTATBBP220-LA
8 pages 0.08 mb -
Thermostat
Bryant T6 WEM
26 pages 2.97 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Bryant TSTATBBPB501, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bryant TSTATBBPB501 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Bryant TSTATBBPB501. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Bryant TSTATBBPB501 should contain:
- informations concerning technical data of Bryant TSTATBBPB501
- name of the manufacturer and a year of construction of the Bryant TSTATBBPB501 item
- rules of operation, control and maintenance of the Bryant TSTATBBPB501 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bryant TSTATBBPB501 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bryant TSTATBBPB501, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bryant service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bryant TSTATBBPB501.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Bryant TSTATBBPB501 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
72 74 70 C OOL H EAT AUTO Mo I2:00 Heat P ump & Heat Cool Meets California T itle 24 Residential Dual Setpoint 5+2 Day Programmable 4 T ime periods V ery Easy to Program Easy T o Read Display Thermoglow Backlight No Batteries Required Auto Changeover No Batteries Required Locking Keypad MODEL TST A TBBPB501 PROGRAMMABLE DIGIT AL THERMOST A T NO[...]
-
Page 2
Ta ble Of Content s FRONT P ANEL DISPLAY QUICK STA RT Set the clock and go BASIC OPERA TION PROGRAMMING 4 Time Periods ADV ANCED SETUP ABOUT ADV ANCED OPERA TION W ARRANTY P age 1 CAUTION Follow Installation Instructions before proceeding . SET THERMOST AT T O MODE “ OFF” PRIOR TO CHANGING SETTINGS IN SETUP OR REST ORING F ACTORY DEF AUL TS. TS[...]
-
Page 3
72 74 70 C OOL H EAT AUTO Mo I2:00 Front Panel P age 2 Liquid Cryst al Display with Thermoglow Up/Down Buttons Mode Button Fan Button Heat or Cool Indicator Heat = Red, Cool = Green 1 2 3 4 5 2 3 4 5 1[...]
-
Page 4
1 2 4 3 Mode Indicators Selects the operation mode of the equipment. HEA T - indicates the heat mode. COOL - indicates the air conditioning mode. AUTO - indicates the system will automatically changeover between heat and cool modes as the temperature varies. OFF - indicates the entire system is turned off. PROGRAM ON - indicates the stored program [...]
-
Page 5
5 6 7 8 Morning, Day , Evening & Night Indication Indicates the program time period. Page 8-1 1. Setup Indication Indicates the thermostat is in the programming mode. Page 12. Fan Operation Indication Fan On - indicates constant, continuous fan operation. When Fan On is not lit - indicates the fan will only operate when necessary to heat or to [...]
-
Page 6
During Setup & Programming: Pressing the Mode button selects different flashing items. (Represented in dark black ) Pressing the Up and Down buttons will modify the flashing selection. Press the Mode button. While holding the Mode, press the Fan button for 2 seconds to enter Setup screens. Press both Mode and Fan buttons as above to return to n[...]
-
Page 7
The HEA T setting indicates the temperature the r oom has to reach befor e the furnace will turn on to heat the room. The COOL setting indicates the temperature the r oom has to reach befor e the air conditioner will turn on to cool the room. OFF indicates both heating and air conditioning systems are turned off . AUTO will automatically select hea[...]
-
Page 8
buttons. In any mode, adjust the desired Set T emperature with Pressing the up/down buttons in Auto mode will adjust both the heat and cool set temperatures simultaneously . Pressing the up/down buttons in Heat or Cool modes will adjust only the heat or cool set temperature. Select Desired T emperature P age 7 Basic Operation 70 72 69 Pm C OOL H EA[...]
-
Page 9
Programming 4 T ime periods P age 8 Press Press Press Press Press the Mode button. While holding the Mode, press the Up button for 2 seconds to enter time period programming. Continued Select the Day of the Week. MoTuW eThFr or SaSu. (Weekday or Weekend schedule) Adjust the start time for Morning. Adjust the heating setpoint for Morning. Adjust the[...]
-
Page 10
MODE Programming 4 T ime Periods P age 9 Press Press Press Press Press Continued Adjust the start time for Day . Adjust the cooling setpoint for Day . (35 - 99) Adjust the start time for Evening. Adjust the cooling setpoint for Evening. (35 - 99) Adjust the heating setpoint for Day . (35 - 99) MODE MODE MODE MODE Day Am MoTuWeThFr I0:30 Day Am MoTu[...]
-
Page 11
Programming 4 T ime Periods P age 10 Press Press Press Press Continued Adjust the start time for Night. Adjust the cooling setpoint for Night. (35 - 99) Adjust the heating setpoint for Evening. (35 - 99) MODE MODE MODE MODE Adjust the heating setpoint for Night. (35 - 99) Evening Pm MoTuWeThFr C OOL H EAT 5:30 75 73 Night Pm MoTuWeThFr I I:30 Night[...]
-
Page 12
Programming 4 T ime Periods P age 11 Press MODE Press the Mode button. While holding the Mode, press the Up button for 2 seconds to exit time period programming. MODE T o Exit Programming Su Sa Select the Day of the Week. MoTuW eThFr or SaSu. (Weekday or Weekend schedule) Continue Time Period Programming Morning through Night as done in previous st[...]
-
Page 13
Advanced Setup P age 12 Press Press Press Continued Adjust the time of day clock. Select the day of the week. Press the Mode button. While holding the Mode, press the Fan button for 5 seconds to enter Setup screens. NOTE: Each step # is located at the top right corner of the display for easy reference. Tip: T o change hours quickly , press and hold[...]
-
Page 14
Advanced Setup P age 13 Press Press Press Press Continued Select the reversing valve polarity for Heat Pump, O or B. (Step 4 only appears if heat pump is on in step 3) Select Electric Heat On or Off. (S tep 5 only appears if heat pump is off in step 3) Adjust the minimum difference between cooling & heating setpoints. Adjust the deadband from 1[...]
-
Page 15
Advanced Setup P age 14 Select the display back- light always On , or Off after 8 seconds. On Off Select thermostat operation in degrees F ahrenheit or C entigrade. C F Press the Mode button. While holding the Mode, press the Fan button for 2 seconds to leave the Setup screens. If no buttons are pressed, the display will leave the setup screens aft[...]
-
Page 16
Advanced Setup P age 15 S tep # Description Range Factory Default 1 T ime of day clock set 24 hour 12:00 Am 2 Day of the week Sun - Sat Monday 3 Heat Pump Off / On Off 4 Reversing V alve polarity O / B O 5 Electric Heat Off / On Off 6 Deadband or T emperature swing 1 - 6 2 7 Forced minimum difference heat/cool 0 - 6 2 8 Cycles per hour d, d1, 2 - 6[...]
-
Page 17
About Advanced Features & Operation P age 16 2 ST AGE OPERA TION - The 2nd S tage of heat or cool is turned on when ( 1 ) the 1st S tage has been on for a minimum of two minutes, and ( 2 ) the temperature spread from the setpoint is equal to or greater than: the setpoint plus the deadband, plus 2 degrees. Heat Setpoint Cool Setpoint Dead Band D[...]
-
Page 18
About Advanced Features & Operation P age 17 ELECTRIC HEA T - Selecting Electric Heat on, page 13, step 5 , will cause the thermostat to turn on the fan any time there is a heat demand. Since all control the fan, this feature should be off is only electric. immediately gas furnaces unless the heater EMERGENCY HEA T - Is a feature available to H[...]
-
Page 19
About Advanced Features & Operation P age 18 KEYP AD LOCK - T o prevent unauthorized use of the thermostat, the front panel buttons may be disabled. T o disable, or ‘lock’ the keypad, press and hold in the Mode button. While holding the Mode button in, press the Up and Down buttons in together . The Locked icon will appear on the display . [...]
-
Page 20
About Advanced Features & Operation P age 19 DUAL SETPOINT BEHA VIOR - The adjustable setpoint range is: 35 - 99 degrees in Fahrenheit and 7 - 35 degrees in Centigrade. When in the modes Heat or Cool, this adjustable range is unhampered. When adjusting any Auto mode, including programming Occupied and Unoccupied periods, the 1050 will not allow[...]
-
Page 21
P age 20 About Advanced Features & Operation F ACTOR Y DEF AUL TS - If, for any reason it is desirable to return all stored settings back to the factory default settings, press the Mode button. While holding the Mode button in, press the Down button for 2 sec. All icons will appear . Press and hold in the Fan button until Fd appears. This reset[...]
-
Page 22
P age 21 P/N 88-347 Rev . 1 W arranty Five- Ye ar Warranty - This Product is warranted to be free from defects in material and workmanship. If defect appears within five years from the date of original installation , whether or not actual use begins on that date, then the product does meet this warranty . A new or remanufactured part , at the manuf[...]