Go to page of
Similar user manuals
-
Water Heater
Bunn FMD-1
40 pages 2.32 mb -
Water Heater
Bunn H5M
20 pages 0.59 mb -
Water Heater
Bunn H5E-DV PC
10 pages 0.51 mb -
Water Heater
Bunn H5X
22 pages 1.58 mb -
Water Heater
Bunn DV PC
9 pages 0.2 mb -
Water Heater
Bunn H5X
9 pages 0.2 mb -
Water Heater
Bunn H5E
22 pages 1.58 mb -
Water Heater
Bunn H5E
9 pages 0.2 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Bunn H5E, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bunn H5E one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Bunn H5E. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Bunn H5E should contain:
- informations concerning technical data of Bunn H5E
- name of the manufacturer and a year of construction of the Bunn H5E item
- rules of operation, control and maintenance of the Bunn H5E item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bunn H5E alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bunn H5E, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bunn service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bunn H5E.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Bunn H5E item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
BUNN-O-MA TIC CORPORA TION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 FAX: (217) 529-6644 www .bunnomatic.com H5E H5X 10420.0000K 06/05 © 1989 BUNN-O-MATIC CORPORATION OPERA TING & SER VICE MANU AL WARNING Very Hot Water Use With Care! ! DISCONNECT FROM POWER SOURCE BEFORE REMOVAL OF ANY PANEL OR REPLACEM[...]
-
Page 2
2 CONTENTS Introduction ................................................. 2 Warranty ...................................................... 2 User Notices ................................................ 3 Electrical Requirements ............................... 4 Plumbing Requirements .............................. 4 Initial Set-Up ................[...]
-
Page 3
3 12593.0000 00831.0000 10044.0000 USER NOTICES The notices on this dispenser should be kept in good condition. Replace unreadable or damaged labels. 00656.0000 10420 072500[...]
-
Page 4
4 ELECTRICAL REQUIREMENTS CAUTION - The dispenser must be disconnected from the power source until specified in Initial Set-Up. This dispenser requires 2-wire, grounded service rated 120, 208, or 240 volts ac, 20 amp, single phase. (Refer to the dispenser’s dataplate for exact voltage requirement.) Electrical Hook-Up CAUTION – Improper electric[...]
-
Page 5
5 INITIAL SET -UP CAUTION - The dispenser must be disconnected from the power source throughout the initial set-up, except when specified in the instructions. 1. Remove the upper rear panel and place the tank heater switch in the “OFF” position and replace the panel. 2. Connect the dispenser to the power sour ce and turn-on the water supply . 3[...]
-
Page 6
6 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic T ech- nical Service Department. • Inspection, testing, and repair of electrical equipment should be performed only by q[...]
-
Page 7
7 TROUBLESHOOTING (cont.) Problem Probable Cause Remedy Automatic refill will not operate after drawing hot water . Water flows into the tank con- tinuously (Dispenser discon- nected from power sour ce). Water flows into the tank con- tinuously (Dispenser connected to power source). Water is cold. 1. No water 2. W ater strainer/flow control 3. Safe[...]
-
Page 8
8 TROUBLESHOOTING (cont.) Problem Probable Cause Remedy Water boils continuously . Dispenser is making unusual noises. Ready indicator will not light. (when temperature is within 4 ° of its selected setting.) 1. T emperature control 2. Lime build-up 1. Solenoid valve 2. Plumbing lines 3. Water supply 1. T emperature control 2. Ready Indicator LED [...]
-
Page 9
9 SERVICE This section provides procedures for testing and replacing various major components used in this dis- penser should service become necessar y . Refer to T roubleshooting for assistance in determining the cause of any problem. Component Access WARNING – Disconnect the dispenser from the power source before the removal of any panel or the[...]
-
Page 10
10 SERVICE (cont.) Electronic Controls Location: The electronic control assembly is located inside the rear of the dispenser . Access will also be needed to the temperature sensor , over flow tube temperature sensor , and liquid level probe located on the tank lid and to the triac assembly located beneath the tank. General: This system controls the[...]
-
Page 11
11 SERVICE (cont.) Electronic Controls (cont.) Liquid Level Control Test Procedure 1. Disconnect the dispenser from the power sour ce. 2. Check the voltage across terminals 3 & 4 of the electronic control assembly with a voltmeter . Con- nect the dispenser to the power sour ce. The indi- cation must be: a.) 100 to 120 volts ac for 100 to 120 vo[...]
-
Page 12
12 SERVICE (cont.) Electronic Controls (cont.) 7. Reconnect the pink wire to terminal 5 of the elec- tronic control assembly . 8. Loosen the compression fitting, remove the probe from the tank lid, and inspect it for mineral depos- its. Replace it if necessary . Keep the exposed ends of the probe away from any metal surface of the dispenser . 9. Ch[...]
-
Page 13
13 SERVICE (cont.) Electronic Controls (cont.) If the indicator was on or blinking, the temperature sen- sor is operating properly , proceed to #7. If the indicator was off, check the sensor connection on the electronic control cir cuit board and/or replace the temperature sensor and the electronic control as- sembly . NOTE - Each temperature senso[...]
-
Page 14
14 SERVICE (cont.) Electronic Controls (cont.) Electronic Controls Removal and Replacement NOTE - Each electronic control assembly is calibrated to a temperature sensor probe. Both components MUST be replaced as a set. 1. Remove all wires from the electronic control as- sembly terminals. 2. Remove the two 8-32 screws holding the electronic control [...]
-
Page 15
15 10420 060305 SERVICE (cont.) Electronic Controls (cont.) Adjustments The H5X dispenser holds the water temperature at the threshhold of boiling. It is not adjustable by the user . The H5E dispenser is factory calibrated for the tem- perature specified on the data plate. If adjustment is required, use the following procedure: 1. Fill the dispense[...]
-
Page 16
16 SERVICE (cont.) Limit Thermostat Location: The limit thermostat is located on the tank lid. T o test the limit thermostat, access will also be needed to the terminal block located at the rear of the dispenser . If voltage was present as described, reconnect the black wire and proceed to #5. If voltage was not present as described, refer to the W[...]
-
Page 17
17 SERVICE (cont.) Safety Overflow Switch Location: The safety overflow switch is located inside the rear of the dispenser inside the copper overflow cup. For testing or removal of the safety overflow switch, access may also be needed by removing the two screws attaching the electronic control assembly to its mount- ing bracket. Test Procedure: 1. [...]
-
Page 18
18 SERVICE (cont.) Solenoid Valve Location: The solenoid valve is located inside the rear of the dis- penser on the right side near the bottom. T o test the solenoid valve, access will also be needed to the electronic control assembly . 7. Check the solenoid valve for coil action. Connect the dispenser to the power sour ce. Listen carefully in the [...]
-
Page 19
19 SERVICE (cont.) Tank Heater Location: The tank heater is located in the tank lid. Test Procedure: 1. Disconnect the dispenser from the power sour ce. 2. Check the voltage across the terminals of the tank heater with a voltmeter . Connect the dispenser to the power sour ce. The indication must be: a.) 100 to 120 volts ac for 100 to 120 volt model[...]
-
Page 20
20[...]
-
Page 21
21[...]
-
Page 22
22 TANK HEATER SW ELECTRONIC CONTROL ASSY 230 VOLTS A C 2 WIRE SINGLE PHASE LIMIT THERMOSTAT SCHEMATIC WIRING DIAGRAM H5XA, H5EA BLU BLU 10332.0001B 09/02 © 2002 BUNN-O-MATIC CORPORATION L1 N WHI/VIO SOL H5XA Only GRN/YEL (PROBE) PNK 20 6 7 3 2 1 5 4 TAN RED RED RED BLK GRN/YEL BLK WHI/BLU RED SAFETY SW RED RED WHI/BRN BLK t ° W H I W H I G R Y G[...]