A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Bunn Smart Wave Series, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bunn Smart Wave Series one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Bunn Smart Wave Series. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Bunn Smart Wave Series should contain:
- informations concerning technical data of Bunn Smart Wave Series
- name of the manufacturer and a year of construction of the Bunn Smart Wave Series item
- rules of operation, control and maintenance of the Bunn Smart Wave Series item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bunn Smart Wave Series alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bunn Smart Wave Series, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bunn service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bunn Smart Wave Series.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Bunn Smart Wave Series item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Smar t W ave Series Smar t W ave Silver Series Series ® INST ALLA TION & OPERA TING GUIDE BUNN-O-MA TIC CORPORA TION POST OFFICE BO X 3227 SPRINGFIELD , ILLINOIS 62708-3227 PHONE: (217) 529-6601 F AX: (217) 529-6644 T o ensure you have the latest revision of the Operating Manual, or to view the Illustrated Parts Catalog, Programming Manual, or[...]

  • Page 2

    Page 2 40410 041108 BUNN-O-MA TIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) All equipment other than as specified below: 2 years parts and 1 year labor . 2) Electronic circuit and/or control boards: parts and labor for 3 years. 3) Compressors on refrigeration equipment: 5 years[...]

  • Page 3

    Page 3 CONTENTS Warranty .............................................................................................................2 Introduction ........................................................................................................3 User Notices ..................................................................................[...]

  • Page 4

    Page 4 ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up. Refer to Data Plate on the Brewer , and local/national electrical codes to determine circuit requirements. Electrical Hook-Up CAUTION – Improper electrical installation will damage electronic components. 1. An electri[...]

  • Page 5

    Page 5 PLUMBING REQUIREMENTS These brewers must be connected to a cold water system with operating pressure between 20 and 90 psi (138 and 620 kPa) from a 1 ⁄ 2 " or larger supply line. A shut-off valve should be installed in the line before the brewer . Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce[...]

  • Page 6

    Page 6 INITIAL SET UP CAUTION - The brewer must be disconnected from the power source throughout the initial set-up, except when specified in the instructions. 1. Insert an empty funnel into the funnel rails. (FIG 4) 2. Place an empty server under the funnel. For taller servers, lift up on the front of the booster plate, and slide it back into the[...]

  • Page 7

    Page 7 COFFEE BREWING 1. Begin each brew cycle with a clean empty brew funnel. 2. Insert a BUNN filter into the funnel. (FIG 6) 3. Pour (or grind) fresh coffee into the filter and level the bed of grounds by gently shaking. 4. Slide the funnel into the funnel rails until it stops. 5. Place an empty server under the funnel. 6. Verify that the &quo[...]

  • Page 8

    Page 8 OPERA TING CONTROLS - SIL VER SERIES (A) ENABLE BREW ON/OFF SWITCH Pressing the "ENABLE BREW ON/OFF" switch (indicator on) enables the brew circuit, and energizes the tank refill circuit. Pressing the switch again (indicator off) stops tank refilling and brewing. Stopping a brew cycle after it has been started will not stop the ?[...]

  • Page 9

    Page 9 40410 092407 PROGRAMMING - SIL VER SERIES BREW VOLUME SET -UP: NOTE: Set small and large batches separately . Maximum water on time is 5 minutes. Use the following steps when the setting is unknown. 1. Place an empty funnel in the funnel rails and an empty server beneath the funnel. 2. Press the "ENABLE BREW ON/OFF" switch ("O[...]

  • Page 10

    Page 10 B C A (A) ENABLE BREW ON/OFF SWITCH Pressing the "ENABLE BREW ON/OFF" switch (indicator/display on) enables the brew circuit, and the tank refill circuit. Pressing the switch again (indicator/display off) stops tank refilling and brewing. Stopping a brew cycle after it has been started will not stop the flow of water into the s[...]

  • Page 11

    Page 11 40410 092407 PROGRAMMING - SMAR T WA VE WITH DISPLA Y BREW VOLUME SET -UP: NOTE: Maximum water on time is 5 minutes. 1. Press the "HIDDEN" switch until display reads A1. This represents the adjust mode "Brew Time" for the "A" brew switch. The display will then change to (minutes-seconds). Press "BREW A&quo[...]

  • Page 12

    Page 12 Remove sprayhead by turning counterclockwise DELIMING Bunn-O-Matic recommends deliming your coffee brewer periodically . The actual frequency of deliming de- pends on the mineral content of the water you use. NOTE: In hard water areas, this may need to be done daily . It will help prevent liming problems in the brewer and takes less than a [...]

  • Page 13

    Page 13 FIG 12 FIG 11 CLEANING The use of a damp cloth rinsed in any mild, non-abrasive, liquid detergent is recommended for cleaning all surfaces on Bunn-O-Matic equipment. CLEANING OPTIONAL LARGE SPRA YHEAD 1. Remove the brew funnel. 2. Remove the sprayhead by turning it counterclockwise with your fingertips. 3. Disassemble sprayhead by removing[...]

  • Page 14

    Page 14 CO VER REMO V AL Unplug the brewer and let it cool down before proceeding. Front Wrap: 1. Remove the brew funnel. 2. Remove upper and lower screws on either side of front cover . 3. Loosen middle screw on either side of front cover . 4. Pull front cover towards front of brewer . T op Cover: 1. Remove both screws. 2. Lift top cover to clear [...]

  • Page 15

    Page 15 DRAINING T ANK 1. Unplug the brewer and let it cool down before proceeding. 2. Remove the brew funnel. 3. Remove the front cover . 4. Pinch fill hose. 5. Loosen clamp from fill solenoid.. 6. Remove hose from solenoid and drain into sink as shown (or 2 gallon bucket). 7. After draining, reinstall hose and clamp. (Hand tighten only) . FIG 1[...]

  • Page 16

    Page 16 1 2 3 4 OFF ON FIG 16 SWITCH SETTINGS Program Switches: 1. Unplug the brewer and let it cool down before proceeding. 3. Remove the left rear cover . 4. Flip the dip switches as needed. NOTE: All switches are turned OFF from factory . FIG 15 KEY # FUNCTION - OFF FUNCTION - ON 4. High altitude Set temp 200°F (93°C) Set temp 190°F (87.8°C)[...]

  • Page 17

    Page 17 TR OUBLESHOO TING 40410 092407 RED LED FLASHES DISPLA Y DESCRIPTION ACTION 1. ER 1 TEMP SENSOR SHORTED CALL SERVICE 2. ER 2 TEMP SENSOR OPEN CALL SERVICE 3. ER 3 HEA TING TOO LONG CALL SERVICE 4. ER 4 REFILL TOO LONG CHECK WA TER SUPPL Y 5. ER 5 HIGH T ANK LEVEL-DURING BREW DELIME 6. ER 6 CHECK "ENABLE BREW ON/OFF" SWITCH CHECK SW[...]

  • Page 18

    Page 18 40410 092407 - SCHEMA TIC WIRING DIAGRAM W A VE 15 APS, 15 S APS 40405.0000B 09/07 ©2007 BUNN-O-MA TIC CORPORA TION T ANK HEA TER LIMIT THERMOST A T VENT V AL VE SOLENOID 12VDC L1 NT BLK BLK-14 120V AC 2 WIRE + GND SINGLE PHASE RED/BLK WHI WHI WHI BLK J2-1 J5-1 BRN - ON/0 OFF ORN +12 ORN GRN T AN WHI/ORN +12 WHI PNK RED/BLK - ON/0 OFF GRN [...]

  • Page 19

    Page 19 - SCHEMA TIC WIRING DIAGRAM W A VE 15 APS, 15 S APS 40405.0001A 02/08 ©2008 BUNN-O-MA TIC CORPORA TION T ANK HEA TER LIMIT THERMOST A T VENT V AL VE SOLENOID 12VDC L1 NT BLU/BLK BLK-14 230V AC 2 WIRE + GND SINGLE PHASE RED/BLK WHI WHI BLU BRN J2-1 J5-1 BRN - ON/0 OFF ORN +12 ORN GRN T AN WHI/ORN +12 WHI PNK RED/BLK - ON/0 OFF GRN YEL WHI/R[...]

  • Page 20

    Page 20 SCHEMA TIC WIRING DIAGRAM W A VE 120/240V APS SERIES 40405.0002A 02/08 ©2008 BUNN-O-MA TIC CORPORA TION 120/240V AC 3 WIRE + GND SINGLE PHASE Chassis Ground Earth Ground GRN/YEL - T ANK HEA TER LIMIT THERMOST A T VENT V AL VE SOLENOID 12VDC L1 NT BLK BLK-14 RED/BLK RED WHI WHI BLK J2-1 J5-1 BRN - ON/0 OFF ORN +12 ORN GRN T AN WHI/ORN +12 W[...]