Bunn T6A manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Bunn T6A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bunn T6A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Bunn T6A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Bunn T6A should contain:
- informations concerning technical data of Bunn T6A
- name of the manufacturer and a year of construction of the Bunn T6A item
- rules of operation, control and maintenance of the Bunn T6A item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bunn T6A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bunn T6A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bunn service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bunn T6A.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Bunn T6A item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    BUNN-O-MA TIC CORPORA TION T3,T3A T6,T6A POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 TELEPHONE: (217) 529-6601 FAX: (217) 529-6644 10145.0000G 7/00 © 1984 Bunn-O-Matic Corporation OPERA TING & SER VICE MANU AL BU N N ®[...]

  • Page 2

    Page 2 CONTENTS Introduction ............................................................................. 2 Warranty .................................................................................. 2 User Notices ............................................................................. 3 Electrical Requirements ..............................[...]

  • Page 3

    Page 3 #00831.0000 #00656.0000 #03408.0000 #03409.0000 USER NOTICES Carefully read and follow all notices on the equipment and in this manual. They were written for your protec- tion. All notices on the equipment should be kept in good condition. Replace any unreadable or damaged labels. 10145 021599[...]

  • Page 4

    Page 4 ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up. 120V model brewers require 2-wire, grounded service rated 120 volts ac, 15 amp, single phase, 60 Hz. "A" model brewers require 2-wire, grounded service rated 240 volts ac, 10 amp, single phase, 50 Hz. "B&q[...]

  • Page 5

    Page 5 INITIAL SET-UP (FILL & HEAT) CAUTION - The brewer must be disconnected from the power source throughout the Initial Set-Up , except when specified in the instructions. 1. Complete the electrical and plumbing instructions prior to starting this procedure. 2. Remove the top panel and check that the thermostat dial is rotated fully counterc[...]

  • Page 6

    Page 6 10. Install the ferrule and screen in the funnel. Load the funnel with a BUNN ® paper filter and approximately four ounces of loose tea leaves. Depress the start button to brew tea and observe the funnel drip out and the dilution streams near the end of the cycle. The dilution stream should stop approximately thirty seconds after the drip o[...]

  • Page 7

    Page 7 B. SELECTOR SWITCH (T6 ONLY) Placing the selector switch in the "ON" (left or right) position allows the start switch to activate a timed brew cycle for three gallons of tea. It also selects into which reservoir dilution water will be introduced. This switch should always be in the "OFF" (center) position after a brew cyc[...]

  • Page 8

    Page 8 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department. • Inspection, testing, and repair of electrical equipment should be performed only by[...]

  • Page 9

    Page 9 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY Brew cycle will not start (cont.) Water is not hot Dilution cycle will not start 5. Start Switch 6. Brew Timer 7. Brew Solenoid Valve 8. Internal Flow control (.195 GPM) 1. Limit Thermostat CAUTION - Do not eliminate or by- pass limit thermostat or thermal cut-off. Use only BOM replacemen[...]

  • Page 10

    Page 10 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY Dilution cycle will not start (cont.) Inconsistent beverage level in dis- penser Consistently high or low beverage level in the dispenser 4. Dilution Solenoid Valve 1. Internal Flow Control (.195 GPM) 2. Syphon System 3. Lime Build-up CAUTION - Tank and tank compo- nents should be delime[...]

  • Page 11

    Page 11 TROUBLESHOOTING (cont.) Spitting or excessive steaming Drip-out time too long Dripping from sprayhead Water flows into tank continuously (ON/OFF or Slector Switch "ON") Water flows into tank continuously (ON/OFF or Selector Switch "OFF") 1. Lime Build-up CAUTION - Tank and tank compo- nents should be delimed regularly de[...]

  • Page 12

    Page 12 TROUBLESHOOTING (cont.) Beverage overflows dispenser Weak beverage 1.Dispenser 2. Brew Timer 3. Brew Solenoid Valve 4. Dilution Timer 5. Dilution Solenoid Valve 1. Filter Type 2. Tea 3. Sprayhead 4. Funnel Loading 5. Water Temperature The dispenser must be completely empty before starting a brew cycle. Refer to Service - Brew Timer for test[...]

  • Page 13

    Page 13 The BUNN ® paper filter must be centered in the funnel and the bed of grounds leveled by gently shak- ing. The nut on the solenoid(s) must be tight or it will vibrate during opera- tion. Plumbing lines should not be rest- ing on the counter top. (A) The brewer must be connected to a cold water line. (B) Water pressure to the brewer must no[...]

  • Page 14

    Page 14 SERVICE This section provides procedures for testing and replacing various major components used in this brewer should service become necessary. Refer to Troubleshooting for assistance in determining the cause of any problem. WARNING - Inspection, testing, and repair of electri- cal equipment should be performed only by qualified service pe[...]

  • Page 15

    Page 15 SERVICE (cont.) BREW SOLENOID VALVE FIG. 2 BREW SOLENOID VALVE P1833.50 Location: Viewing the brewer from the rear the brew sole- noid valve is mounted on the left side of the mounting bracket. Test Procedures: 1. Disconnect the brewer from the power source. 2. Disconnect the white/violet and white/green wires from the solenoid valve. With [...]

  • Page 16

    Page 16 FIG.3 SOLENOID VALVE TERMINALS P1834 SERVICE (cont.) BREW SOLENOID BREW SOLENOID DILUTION SOLENOID RT RESERVOIR DILUTION SOLENOID LT RESERVOIR DILUTION SOLENOID WHI/BLU to Dilution Timer TL4 BRN/BLK to Selector Switch YEL to Selector Switch WHI/GRN to Brew Timer TL4 WHI/VIO to Brew Timer TL1 T6 WHI/BLU to Dilution Timer TL4 WHI/VIO to Brew [...]

  • Page 17

    Page 17 BREW TIMER FIG. 4 BREW TIMER P1833 Location: The brew timer is located in the hood. It consists of the left dial plate and circuit board. Test Procedure: 1. Disconnect the brewer from the power source. 2. Remove the wires from terminals TL3, TL4, & TL5 of the timer and rotate the dial fully counterclock- wise. 2. With a voltmeter, check[...]

  • Page 18

    Page 18 Location: The timer is located inside the hood, attached to the left side. Test Procedure. NOTE: Do not remove or install wires while timer board is installed. Pressure applied to one side may cause damage to the board. 1. Disconnect the brewer from the power source and remove the front access panel. 2. Remove the two #8-32 screws securing [...]

  • Page 19

    Page 19 TL1 - WHI/VIO to Dilution Timer and WHI/VIO to ON/OFF Switch TL2 - WHI to Power Cord (100V & 120V) or RED to Power Connector (240V) and WHI to Dilution Timer (100V & 120V) or RED to Dilution Timer (240V) TL3 - WHI/ORN to Start Switch TL4 - WHI/GRN to Brew Solenoid TL5 - WHI/YEL to Start Switch J2-2 - PNK to Selector Switch (Half Bat[...]

  • Page 20

    Page 20 240 volt two wire models when the control ther- mostat is turned fully clockwise. Connect the brewer to the power source. The indication must be: a) 120 volts ac for two wire 120 volt models. b) 240 volts ac for two wire 240 volt models. c) 100 volts ac for two wire 100 volt models. 8. Disconnect the brewer from the power source. If voltage[...]

  • Page 21

    Page 21 DILUTION SOLENOID VALVE(S) FIG. 10 DILUTION SOLENOID VALVE(S) P2207.40 Location: Viewing the brewer from the rear the dilution so- lenoid for the T3 is mounted on the center of the sole- noid mounting bracket, the T6 solenoids are mounted in the center and the right side of the mounting bracket. Test Procedure: 1. Disconnect the brewer from[...]

  • Page 22

    Page 22 If continuity is present as described, reconnect the wires to terminals TL3, TL4, & TL5 of the timer board and proceed to #5. If continuity is not present as described, refer to the Wiring Diagrams and check the wiring harness. 5. With a voltmeter, check the voltage across termi- nals TL1 and TL4 when the ON/OFF or selector switch is in[...]

  • Page 23

    Page 23 LIMIT THERMOSTAT FIG. 13 LIMIT THERMOSTAT P2207.40 Location: The limit thermostat is located inside the hood on the tank lid. Test Procedure: 1. Disconnect the brewer from the power source and remove the black wire from the limit thermostat. 2. With a voltmeter, check the voltage across the black wire removed from the limit thermostat and t[...]

  • Page 24

    Page 24 6. Check for continuity across the center and end terminals of the top row when the switch is in the “ ON ” (left) position. If continuity is present as described, replace the wires, the switch is operating properly. If continuity is not present as described, replace the switch. T3 Brewers W/Half Batch Option 1. Disconnect the brewer fr[...]

  • Page 25

    Page 25 SERVICE (cont.) T6 Brewers 1. Disconnect the brewer from the power source. 2. Remove the black wire from the top center switch terminal. 3. With a voltmeter, check the voltage across the black wire removed from the selector switch and the white wire or red wire on the tank heater. 4. Connect the brewer to the power source.The indi- cation m[...]

  • Page 26

    Page 26 If continuity is present as described, reconnect the wires, the switch is operating properly. If continuity is not present as described, replace the switch. Removal and Replacement: 1. Remove the wires from the switch terminals. 2. Compress the clips inside the hood and gently push the switch through the opening. 3. Push the new switch into[...]

  • Page 27

    Page 27 TANK HEATER FIG. 19 TANK HEATER Location: The tank heater is located inside the tank and se- cured to the tank lid. Test Procedures: 1. Disconnect the brewer from the power supply. 2. With a voltmeter, check the voltage across the black and white wires on 100 volt and 120 volt models or the black and red wires for 240 volt models. Connect t[...]