Bunn VPS manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Bunn VPS, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Bunn VPS one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Bunn VPS. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Bunn VPS should contain:
- informations concerning technical data of Bunn VPS
- name of the manufacturer and a year of construction of the Bunn VPS item
- rules of operation, control and maintenance of the Bunn VPS item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Bunn VPS alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Bunn VPS, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Bunn service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Bunn VPS.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Bunn VPS item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    BU N N ® OPERA TING & SER VICE MANU AL B UNN-O-MA TIC CORPORA TION OF CANAD A L TD . 280 INDUSTRIAL PKWY . S. AURORA, ONT ARIO L4G 3T9 PHONE: (905) 841-2866 F AX: (905) 841-2775 10053.7000J 11/01 ©1996 Bunn-O-Matic Corporation www.bunnomatic.com VPR VPS P O U R IN W A T E R O N L Y P O U R IN W A T E R O N L Y[...]

  • Page 2

    Page 2 INTRODUCTION This equipment will brew a half-gallon batch of coffee into an awaiting dispenser. It is only for indoor use on a sturdy counter or shelf. W ARRANTY Bunn-O-Matic Corp. (“Bunn”) warrants the equipment manufactured by it to be commercially free from defects in material and workmanship existing at the time of manufacture and ap[...]

  • Page 3

    Page 3 USER NOTICES Carefully read and follow all notices in this manual and on the equipment. All labels on the equipment should be kept in good condition. Replace any unreadable or damaged labels. #12364.7000 #00833.7001 #00658.7000 #00831.0002 10053 022300[...]

  • Page 4

    Page 4 ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up. The brewer has an attached cordset and requires 2-wire grounded service rated 120 volts ac, 15 amp, single phase, 60 Hz. Electrical Hook-Up (Model "A" Only) CAUTION – Improper electrical installation will dam[...]

  • Page 5

    Page 5 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department. • Inspection, testing, and repair of electrical equipment should be performed only by[...]

  • Page 6

    Page 6 TROUBLESHOOTING (cont.) PROBLEM Dripping from sprayhead Beverage overflows dispenser Weak beverage PROBABLE CAUSE REMEDY 1. Lime Build-up CAUTION - Tank and tank components should be delimed regularly depending on local water conditions. Excessive mineral build-up on stainless steel surfaces can initiate corro- sive reactions resulting in se[...]

  • Page 7

    Page 7 TROUBLESHOOTING (cont.) PROBLEM Dry coffee grounds remain in the funnel Brewer is making unusal noises Cool beverage serving tempera- ture PROBABLE CAUSE REMEDY 1. Funnel Loading 1. Tank Heater 1. ON/OFF Warmer Switch 2. Warmer Element(s) The BUNN ® paper filter must be centered in the funnel and the bed of grounds leveled by gently shak- i[...]

  • Page 8

    Page 8 P O U R IN W A T E R O N L Y P O U R IN W A T E R O N L Y SERVICE This section provides procedures for testing and replacing various major components used in this brewer should service become necessary. Refer to Troubleshooting for assistance in determining the cause of any problem. WARNING - Inspection, testing, and repair of electri- cal e[...]

  • Page 9

    Page 9 FIG. 3 CONTROL THERMOSTAT CONTROL THERMOSTAT Location: The control thermostat is located inside the hood on the left end of the mounting bracket. Test Procedures: 1. Disconnect the brewer from the power source. 2. Locate the black wire on the control thermostat. 3. Check the voltage across the black wire on the control thermostat and the whi[...]

  • Page 10

    Page 10 FIG. 6 LIMIT THERMOSTAT TERMINALS SERVICE (cont.) CONTROL THERMOSTAT (cont.) LIMIT THERMOSTAT - VPR, VPS Location: The limit thermostat is located inside the hood on the right side of the tank lid. P2414 FIG. 5 LIMIT THERMOSTAT P1800 BLK to Tank Heater BLU/BLK to Control Thermostat 10053 073001 2. Remove the thermostat capillary bulb by fir[...]

  • Page 11

    Page 11[...]

  • Page 12

    Page 12 TANK HEATER Location: The tank heater is located inside the tank and secured to the tank lid. Test Procedures: 1. Disconnect the brewer from the power supply. 2. Check the voltage across the black and white wires on 120 volt models or the black and red wires for 220 volt models with a voltmeter. Plug- in the brewer to the power source. The [...]

  • Page 13

    Page 13 SERVICE (cont.) TANK HEATER (Cont.) BLK to Limit Thermostat (120V Models) Thermal Cut-off to Blu/BLK Lead From Control Thermostat (220V T wo Wire Models) WHI to WHI Lead on Power Cord (120V Models) Thermal Cut-off to Red from Power Connector (220V T wo Wire Models) P1254 FIG. 10 TANK HEATER TERMINALS THERMAL CUT-OFF - VPRA, VPSA BUNN OFF HI[...]

  • Page 14

    Page 14 SERVICE (cont.) WHI to WHI Lead on Power Cord (120V Brewers) RED to Power Connector (220V Brewers) WHI /RED, VIO or BRN/BLK to ON/OFF Switch P1255 FIG. 14 WARMER ELEMENT TERMINALS WARMER ELEMENTS[...]

  • Page 15

    Page 15 L1 BLK TANK HEATER WHI LOWER WARMER 1150W BLK SCHEMATIC WIRING DIAGRAM VPR GREEN N WHI WHI BLK 10050.0000D 1/97 © 1988 BUNN-O-MATIC CORPORATION UPPER WARMER WHI WHI BLK 120 VOLTS A C 2 WIRE SINGLE PHASE 60 HZ WHI/RED WHI/RED VIO VIO 100W 100W LIMIT THERMOSTAT BLU/BLK SW. & THERMOSTAT ON/OFF SWITCH ON/OFF SWITCH IND IND 10053 073001 L1 [...]

  • Page 16

    Page 16 SW. & THERMOSTAT L1 LOWER WARMER 2000W 100W BLK SCHEMATIC WIRING DIAGRAM VPRA GRN/YEL BLU/BLK L2 BLK RED UPPER WARMER 100W BLK IND IND IND BLK 220 VOLTS A C 2 WIRE SINGLE PHASE TANK HEATER RED RED RED RED RED THERMAL CUT-OFF THERMAL CUT-OFF ON/OFF SWITCH ON/OFF SWITCH WHI/RED WHI/RED VIO VIO 10053 073001 LIMIT THERMOSTAT L1 BLK WHI LOWE[...]

  • Page 17

    Page 17 SW. & THERMOSTAT L1 LOWER LEFT WARMER 2000W 100W BLK SCHEMATIC WIRING DIAGRAM VPSA GRN/YEL BLU/BLK L2 BLK RED UPPER WARMER 100W BLK IND IND IND LOWER RIGHT WARMER 100W BLK IND BLK 220 VOLTS A C 2 WIRE SINGLE PHASE TANK HEATER RED RED RED RED RED RED RED THERMAL CUT-OFF THERMAL CUT-OFF ON/OFF SWITCH ON/OFF SWITCH ON/OFF SWITCH WHI/RED WH[...]