Campbell Manufacturing RF415 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Campbell Manufacturing RF415, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Campbell Manufacturing RF415 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Campbell Manufacturing RF415. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Campbell Manufacturing RF415 should contain:
- informations concerning technical data of Campbell Manufacturing RF415
- name of the manufacturer and a year of construction of the Campbell Manufacturing RF415 item
- rules of operation, control and maintenance of the Campbell Manufacturing RF415 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Campbell Manufacturing RF415 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Campbell Manufacturing RF415, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Campbell Manufacturing service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Campbell Manufacturing RF415.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Campbell Manufacturing RF415 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    INSTRUCTION MANUAL RF400/RF410/RF415 Spread Spectrum Data Radio/Modem Revision: 3/05 Copyright (c) 2001-2005 Campbell Scientific, Inc.[...]

  • Page 2

    Warranty and Assistance The RF400 SERIES S PREAD SPECTRUM DATA RADIO/MODEM S are w arranted by CAMPBELL SCIENTIFIC, INC. to be free f rom def ects in materials and w orkman ship un der normal u se and service f or twelv e (12) months from da te of shi pment unless sp ecifi ed o therwise. B atte ries have no w arranty. C AMPBELL S CIENTIFIC, INC.&ap[...]

  • Page 3

    – CAUTION – Where an A C ada pter is used, CSI r ecomme nds Item # 15966. This A C adap ter is included as part of Item # 14220 RF40 0 Series Base Sta tion Cable/Pow er Kit. Any other AC adapter used must ha ve a DC outp ut not exceeding 1 6.5 Volts measure d w ithout a load to avoid damage to t he RF400 Series radi o! Over-voltage dam age is n[...]

  • Page 4

    This is a blank page.[...]

  • Page 5

    i RF400 Series Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab for links to specific sections. 1. Introducti on ................................................................. 1 2. RF400 Seri es Specifications ...................................... 2 3. Qu[...]

  • Page 6

    RF400 Table of Contents ii C. RF400 Series A ddress and Address Mask ........... C-1 D. Advanced Setup Standby Modes ......................... D-1 E. RF400 Series Po rt Pin Descriptions ..................... E-1 F. Datalogger RS-232 Por t to RF400 Series Radi o ... F-1 G. Short-Haul Modems ............................................... G-1 H. Dist[...]

  • Page 7

    RF400 Table of Contents iii K-1. 900 MHz Gain A ntenn a Test Distances..............................................K-6 L-1. A dvanced Setup Men u ........................................................................ L-1[...]

  • Page 8

    RF400 Table of Contents iv This is a blank page.[...]

  • Page 9

    1 RF400 Series Spread Spectrum Data Radio/Modems 1. Introduction This manu al covers th e RF400 series radios — the RF400, R F410, and RF415. These radios dif fer from one another prim arily in the radio f requenci es at which th ey communicate. In this manual the term “RF400” can refer to the “RF400 series” or to th at specific model. Fo[...]

  • Page 10

    RF400 Series Spread Sp ec trum Data Rad io/ Mod ems 2 FIGURE 1. RF400 The RF400 ha s a 9-pin serial CS I/O port and a 9-pi n serial DCE R S-232 port. The CS I/O port al lows th e RF400 to connect t o a datalogger. The R S-232 port allows direct PC connection for Setup Menu access and to create a direct connect RF400 “base st ation” for poin t-t[...]

  • Page 11

    RF400 Series Spread Sp ec trum Data Rad io/ Mod ems 3 Quiescent Curre nt in Standby Mo des* Avg. Quies cent Current (mA) Advanced S etup Standby M ode Standard Setup RF400/ RF410 R F415 24.0 33.0 0 (no duty cycling) 1 3.9 5.5 3 2 2.0 2.8 4 3 1.1 1.5 5 0.64 0.84 6 0.40 0.50 7 4 * Not receiving a signal nor transmitting PHYSICAL • Size 4.75 x 2.75 [...]

  • Page 12

    RF400 Series Spread Sp ec trum Data Rad io/ Mod ems 4 For this system you will need the followin g hardware or the equivalent: 1. Two RF 400s 2. Two RF400 an tennas 3. AC adapter (It em # 15966 or part of k it #14220) 4. Serial cable (6 ft.) for PC COM port to RF 400 RS-232 p ort (Item # 10873 or part of Item # 1422 0) 5. SC12 cable (i ncluded w it[...]

  • Page 13

    RF400 Series Spread Sp ec trum Data Rad io/ Mod ems 5 apx TECHNOLOGIES  INC. CLASS  2  TRANSFORMER MODEL  NO:  AP2105W INPUT: 120VAC  60Hz  20W LISTED 2H56 E144634 MADE  IN  CHINA OUTPUT: 12VDC  1.0A HICKSVILLE,  NEW  YORK U L R U L R RS232 DC Pwr CS I/O Pwr/TX RX MADE IN USA Serial # Program Anten[...]

  • Page 14

    RF400 Series Spread Sp ec trum Data Rad io/ Mod ems 6 Current dat aloggers an d wiring pan els (not mention ed in Table 1) prov ide 12 V on pin 8. For older products not listed, ch eck for 12 V betw een CS I/O connector pin 8 and pin 2 (GND) or contact Campbell Scientific. c. Use defaul t settings of R F400. Step 3 – LoggerNet/PC208W Set-up a. Th[...]

  • Page 15

    RF400 Series Spread Sp ec trum Data Rad io/ Mod ems 7 Auto Sense The RF400 has a default feature call ed “Auto Sense” th at automatically configures certain RF400 settings. When you connect an RF400 to a datalogg er (CS I/O port to C S I/O port) th e RF400 detects t he presence of the datalogger an d makes its CS I/O port the active port. When [...]

  • Page 16

    RF400 Series Spread Sp ec trum Data Rad io/ Mod ems 8 Green LED activity indicates that there is an RF signal being received wh ose hopping sequence correspon ds to the conf igured hopping sequence of the RF400. This does not necessarily mean that the network/radio address of the received packet corres ponds wi th that of the RF400 (w here a neighb[...]

  • Page 17

    RF400 Series Spread Sp ec trum Data Rad io/ Mod ems 9 The Standard Setup stan dby modes automatically configure: • Time of Inactivity to Sleep • Time of Inactivity to Long Header • Long Header Tim e The defaul t mode is the S tandard Setup m enu selection “2” for “ < 4 mA and ½ sec Cycle.” There are standby modes available in addi[...]

  • Page 18

    RF400 Series Spread Sp ec trum Data Rad io/ Mod ems 10 4.1.3.2 ATDT Command Mod e This mode i s not requi red for basic poin t-to-poin t communication. For point -to-mult ipoint operation the RF400 can temporarily be put into A T Command Mode by sending a string of three A SCII characters. The defaul t sequen ce to enter AT Command m ode is: 1. No [...]

  • Page 19

    RF400 Series Spread Sp ec trum Data Rad io/ Mod ems 11 Retries”, “Ti me-slots for Random Retry”, and “Bytes T ransmitted before Delay” settings. STAND ARD RET RY LEVEL S Menu Retry Leve l Maximum Retries Time-Slots for Rando m Retry Bytes Tr ansmitted Before De lay 1 None 0 0 65535 2 Low 3 2 1000 3 Medium 6 3 1000 4 High 10 5 1000 4.1.4.2[...]

  • Page 20

    RF400 Series Spread Sp ec trum Data Rad io/ Mod ems 12 For example, if you input a value of 50, then packets with hop s ync info will be sent out every 5 seconds im proving (sh ortening) the respon se time of a transmit/response sequence. Even though this shortens the time required to send x amount of dat a, the throughpu t is still det ermined by [...]

  • Page 21

    RF400 Series Spread Sp ec trum Data Rad io/ Mod ems 13 (CSI Item # 14291) wi th tinned leads to connect to pow er at the datalogg er 12 V outpu t terminals and barrel connector to pl ug in to the RF400’s “ DC Pwr” jack. If 120 VA C is availa ble at the site, t he 120 VAC adapter al one (CSI Item # 15966) i s an option . A 12 V s upply may con[...]

  • Page 22

    RF400 Series Spread Sp ec trum Data Rad io/ Mod ems 14 CSI AC adapter Item # 15966 voltag e regulation (ty pical) while pl ugged into an AC out let deliv ering 120.0 VAC: TABLE 3. 159 66’s Volt age Regulati on Current Drain (m A) Resistive Lo ad (Ohms) AC Adapter Output (Volts) 0 (no load) ∞ (open circui t) 12.22 122 100 Ω 12.20 807 15 Ω 12[...]

  • Page 23

    RF400 Series Spread Sp ec trum Data Rad io/ Mod ems 15 A rem ote RF400 can be conn ected to a CR23X’ s or CR5000’ s RS-232 port with a nu ll modem DB9M/DB9M cabl e (CSI Item # 14392). See Appen dix F for detai ls on pow er supply . 4.4 Antennas for the RF400 Se ries Several antennas are off ered to satisfy the needs f or various base station an[...]

  • Page 24

    RF400 Series Spread Sp ec trum Data Rad io/ Mod ems 16 WISP24015P TNF, boom length 17 in ches, diamet er 3 inches, W/ END MOUNT to fit 1 to 2 in. O.D. mast (requires eith er (1) COAX RPSMA-L for sh ort runs or (2) COAX NTN-L with Anten na Surge Protector Kit) COAX RPSM A-L LMR 195 A NTENNA CA BLE, REVERSE PO LARITY SMA TO TYPE N M AL E COAX NTN-L R[...]

  • Page 25

    RF400 Series Spread Sp ec trum Data Rad io/ Mod ems 17 ITEM # 14204 9 00 MHZ OM NI ½ WAVE WHIP 0 dBd ITEM # 14201 900 MHZ YAGI 9 dBd w /MOUNT S ITEM #14205 900 MHz YAGI 6 dBd w/MOUNTS ITEM # 14221 9 00 MHZ OMNI C OLLINEAR 3 dBd w /MOUNTS[...]

  • Page 26

    RF400 Series Spread Sp ec trum Data Rad io/ Mod ems 18 ITEM #15970 9 00 MHZ Indoor O MNI 1 dBd Win dow /Wall Mounted ITEM #16005 2. 4 GHz OMN I HALF WAV E WHIP 0 dBd ITEM #16755 2.4 GHz ENCLOSED YAGI, 13 dBd w/MOUNTS FIGURE 4. S ome FCC Approved Antennas[...]

  • Page 27

    RF400 Series Spread Sp ec trum Data Rad io/ Mod ems 19 FIGURE 5 . Examp le COAX RPSMA-L C able f or Yagi or Omn i Colinear FIGURE 6. Antenna Surge Protector 4.5 Antenna Cables and Surge Pr otecti on 4.5.1 Ant enna Cables The 14201, 14 203, 14205, 14221, and 16755 ant ennas requi re an antenna cable; either (1) the COAX RPSM A or (2) the COAX NTN wi[...]

  • Page 28

    RF400 Series Spread Sp ec trum Data Rad io/ Mod ems 20 • When use of CO AX RPSMA would resu lt in too much si gnal loss (see page H- 3) • When the R F400 series radio will be u sed in an envi ronment sus ceptible to lightning or electro-static buildup 4.5.3 Ant enna Surge Protecto r Kit The Surge Prot ector Kit for th e RF400 series radios incl[...]

  • Page 29

    RF400 Series Spread Sp ec trum Data Rad io/ Mod ems 21 5. Software Setup 5.1 Point-to-point Set-up param eters are conf igured the s ame for the two RF400s . The RF400 defaul ts to radio address “ 0” (zero) wh ich works for m any applications . See Section 4.2 for powe r supply options. 5.2 Poi nt-to-multipoi nt The radio address es for a base [...]

  • Page 30

    RF400 Series Spread Sp ec trum Data Rad io/ Mod ems 22 Main Menu SW Version 6.425 (for exam ple) (1) Standard Setu p (2) Adva nced Setup (3) Restore Def aults (4) Show All Current and Default Settin gs (5) Save All Parameters and Exit Setup (9) Exit Setup without Saving Parameters Enter Choice: 4. Press “1” for Stan dard Setup Display: Standard[...]

  • Page 31

    RF400 Series Spread Sp ec trum Data Rad io/ Mod ems 23 c. Select a R adio Address (0 – 1023). The radio addresses m ust be the same in point-to- point commun ications (for poi nt-to-m ultipoint communicat ions you could s et the base RF400 to 0 an d the rem otes to 1, 2, 3, etc.). It is a good idea to label each R F400 indicating the conf igured [...]

  • Page 32

    RF400 Series Spread Sp ec trum Data Rad io/ Mod ems 24 2. Point-to-multipoi nt a. Complete steps 1 to 4 above making the remote stations’ Networ k Address es and Hopping S equences the same as the base s tation’s. b. W hile in Standard Setup verify t hat the active interface is “A uto Sense” and g ive each remote RF400 a un ique Radio Addre[...]

  • Page 33

    RF400 Series Spread Sp ec trum Data Rad io/ Mod ems 25 power and intermittent repeater sites ma y not be a problem. Test such a site with a representative setup b efore committing to it (see Troubleshooting Sectio n 6). Keep in mind that commercial sites te nd to evo lve. Such a si te ma y wor k no w but could cha nge in t he f uture with the addit[...]

  • Page 34

    RF400 Series Spread Sp ec trum Data Rad io/ Mod ems 26 RF400 RF400 RF400 RF400 DA T ALOGGER DA T ALOGGER DA T ALOGGER FIGURE 8. P oint-to-M ultipoint System 5.3.4 PC2 08W Configuration a. Point-to-point (1) Device Map - COM1 CR10X 1 (2) Set st ation CR10X1 baud rate to 9600 baud i n network map (3) Datalogger extra res ponse time – 0 mS b. Point-[...]

  • Page 35

    RF400 Series Spread Sp ec trum Data Rad io/ Mod ems 27 (4) Datalogger Station Settings (a) Exa mple “D ia led U sing Ge ner ic Di al Str ing” : D1000 T"+++" R"OK"9200 T"A TDT3001^m "R"OK"1200 T"A TCN ^m"R "OK "120 0 (i) D1000 creates a 1 second delay (ii) T sends quoted strin g w/o wai[...]

  • Page 36

    RF400 Series Spread Sp ec trum Data Rad io/ Mod ems 28 6. Troubleshooting If you can’t conn ect, check out these pos sible causes: 1. Datalogg er or Wiring Panel lacks 12 V pow er on pin 8 of CS I/O port The RF400 shou ld go through its initialization with red and green LEDs lighting (s ee Section 4.1.1) when serial cable is conn ected if 12 V is[...]

  • Page 37

    RF400 Series Spread Sp ec trum Data Rad io/ Mod ems 29 7. RF400 receiver “ de-sensing” from nearb y transmitter This problem can be observ ed from LED beh avior when operating a hand- held radio near an RF400 that is receiving collected data from a remote station . If you key a hand-h eld 150 MHz or 450 MHz trans mitter, even though its frequen[...]

  • Page 38

    RF400 Series Spread Sp ec trum Data Rad io/ Mod ems 30 10. PC208W.dn d file corru pted The remote possibility e xists that this file has beco me corrupted in y our PC. Aft er you create the N etwork Map in PC208W, you can back up PC208W.dn d in case th is should h appen. If this appears likely , exit PC208W an d copy and pas te your backup fi le ov[...]

  • Page 39

    A-1 Appendix A. Part 15 FCC Compliance Warning Changes or modifi cations to the RF400 s eries radio sy stems n ot expressly approved by Campbell Scient ific, Inc. could void the user’s authority to operate thi s product. Note: This equip ment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of [...]

  • Page 40

    Thi s is a b lank pa ge.[...]

  • Page 41

    B-1 Appendix B. Setup Menu Here is th e structure of th e RF400 series’ built-in Setup Men u system which can be accessed by conf iguring a term inal e mulator prog ram such as Procomm TM or Hy perTe rm ina l TM to 9600 baud ( 8-N-1) an d pressing th e “Program” but ton on the RF400 w ith RF400’ s RS-232 port cabled to app ropriate CO M por[...]

  • Page 42

    Append ix B. S etup Menu B-2 ii) Radio Stan dby Modes (1) Standby Mode (0 => 24 m A Always O N 3 => 4 mA 1/2 sec Cycle) (4 => 2 m A 1 sec Cy cle 5 => 1 mA 2 se c Cycle) (6 => .6 m A 4 sec Cy cle 7 =>. 4 mA 8 se c Cycle) (2) Time of Inactivity to Sleep (uni ts of 100 ms ec; 1 – 32767) (3) Time of Inactivity to Long Header (uni ts[...]

  • Page 43

    Append ix B. S etup Menu B-3 4 => 38.3k (2) RS-232 Pari ty: 0 => None 1 => Odd 2 => Even (3) RS-232 Ch aracter Length: 0 => 8 bits 1 => 7 bits (4) RS-232 S top Bits: 0 => 1 1 => 2 3) Restore Default s 4) Show All Current and De fault Settings 5) Save All Parameters and Exit Setup 6) Exit Setup without Saving Para meters[...]

  • Page 44

    Append ix B. S etup Menu B-4 This is a blank page.[...]

  • Page 45

    C-1 Appendix C. RF400 Series Address and Address Mask Address An RF400’ s address is 16 bits : (0 - 1111,11 11,1111,11 11) binary (0 - ffffh ) hexadecimal 0 – 65535) decimal The two parts of the address are the “N et work Address ” and the “Radio Address .” The six most significant bits of the address are the “Network Address”, and [...]

  • Page 46

    Appendix C. RF400 Series A ddress an d Addres s Mas k C-2 four bi ts are not com pared, any remote RF400 w ith Radi o Address of 0 t o 1111 (decimal 0 to 15) will be received by the base statio n. This allo ws multiple remotes in a network to be received b y the base without changing th e base Radio Address (th e remotes cannot receive the base, ho[...]

  • Page 47

    Appendix C. RF400 Series A ddress an d Addres s Mas k C-3 NET ADDRESS (decimal) RADIO ADDRESS (decimal) COMBINED 16-BIT A DDRESS (hexadecimal) 0 29 001D 0 30 001E 0 31 001F 0 32 0020 0 1022 03FE 0 1023 03FF 1 0 0400 1 1 0401 2 0 0800 2 1 0801 3 0 0C00 3 1 0C01 4 0 1000 4 1 1001 5 0 1400 5 1 1401 6 0 1800 6 1 1801 7 0 1C00 7 1 1C01 8 0 2000 8 1 2001[...]

  • Page 48

    Appendix C. RF400 Series A ddress an d Addres s Mas k C-4 NET ADDRESS (decimal) RADIO ADDRESS (decimal) COMBINED 16-BIT A DDRESS (hexadecimal) 15 0 3C00 15 1 3C01 16 0 4000 16 1 4001[...]

  • Page 49

    D-1 Appendix D. Advanced Setup Standby Modes The Standard Setup menu selections should fill the majority of user needs. The following inform ation is given in case you need to prog ram a non- standard standby mode. The Standard Setu p menu select ions do not cor respond wit h Advanced Setup menu entries. For example: s electing a “3” in the Sta[...]

  • Page 50

    Appendix D. Advanc ed Setu p Stan dby Modes D-2 In general, t hese inactivity tim ers should be set so th at the RF400 stays on (receiving or transmitting, not in standby mode) longer than the quiet times during communi cation. You can experiment with this to see how it works. TIME OF INA C TIV ITY TO S L EEP The amount of receiver inactivity time [...]

  • Page 51

    E-1 Appendix E. RF400 Series Port Pin Descriptions RS-232 Po rt The “RS 232” port is a partial implem entation of RS- 232C. It is configured as Data Communications Equipment (DCE) for direct cable co nnection to Data Terminal Equipm ent (DTE ) such as an IBM-PC serial port. RS-232 CONNECTOR, 9-PIN D-SUB FEM ALE PIN I/O DESCRIPTION 1 2O T X 3I R[...]

  • Page 52

    Append ix E. RF40 0 Series Port Pin Desc riptio ns E-2 CS I/O CONNECT OR, 9-PIN D-SUB M ALE PIN FUNCTION I/O DESCRIPTION 1 5V I Sources 5 VDC t o po w er peripherals 2 GND GND for pin 1 and signals 3 Ring O Raised by modem to p ut datalogger into telecommunications mode 4 RX O Serial data receive line 5 Modem Enabl e I Raised w hen datalogger deter[...]

  • Page 53

    F-1 Appendix F. Datalogger RS-232 Port to RF400 Series Radio A conn ection from RF400 RS- 232 port to CR23X or CR5000 RS -232 port requires a 9-pin male to 9-pin male null-modem cable. This cable is ava ilable as CSI It em # 14392. A 12- Volt Field Pow er Cable (It em # 14291) or AC adapt er (Item # 1596 6) must be i nstalled to fu rnish 12 V to t [...]

  • Page 54

    Thi s is a b lank pa ge.[...]

  • Page 55

    G-1 Appendix G. Short-Haul Modems Set SRM-5A at PC end to “DCE” mode. Set SR M-5A at RF400 end to “ DTE” mode. The PC to SR M-5A cable is typically a 9- pin female t o 25-pin male (CS I Item # 7026). The SRM-5A to RF400 cable is 25-pin m ale to 9-pi n male availa ble as CSI It em # 14413. Logg erNet or PC208W Net work Map: COM1 CR10X 1 RCV [...]

  • Page 56

    Appendix G. Shor t-Haul Modems G-2 With short-h aul modems it is necessary to conf igure the base stati on RF400’ s “RS-232 Auto Pow er Down Enable” (in th e Advanced Setup In terface Parameters menu) to mode "0" w hich will m aintain the radio' s RS-232 port alw ays active. This results in an additional constant 2 mA c urren[...]

  • Page 57

    H- 1 Appendix H. Distance vs. Antenna Gain, Terrain, and Other Factors RF Path Examples Distance Achieved (miles) Antennas P ath Between Ra dios 2 14204 OMNI ½ Wave 0 d Bd* Whi p to 14204 OMNI ½ Wave 0 d Bd Whip Virtual line-of-sight on valley floor with wetland foliage. 10 14204 OMNI ½ Wave 0 d Bd Whip to 14204 OMNI ½ Wave 0 d Bd Whip Line -of[...]

  • Page 58

    Appendix H. Distanc e vs . Antenn a Gain, Ter rain, and Other F actor s H-2 How Far Can You Go? Distance E stimates for Spread Spectrum Radios Overview There is a great deal of interes t in estimating the distance you can expect to achieve with t he RF400 radios. A lso of interes t are the effects of cable length, antenna gain, and terrain . Some o[...]

  • Page 59

    Appendix H. Distanc e vs . Antenna G ain, Ter rain, an d Other F actors H-3 Pr => sign al po w er at the radio receiver in dBm The signal power at th e receiver (Pr) must exceed the receiv er sensitivity ( − 110 or –10 4 dBm ) by a minimum of 6 dB for an eff ective link. The am ount that Pr exceeds –110 d Bm or –104 dBm (2.4 GHz) is the [...]

  • Page 60

    Appendix H. Distanc e vs . Antenn a Gain, Ter rain, and Other F actor s H-4 Antenna Gain Antenna gain is specified either in dBi (d ecibels of gain relative to an isotropic radiator) or in dBd (decibels of gain relative to a dipole). The relationship is: dBi = dBd + 2.15 Some antenn as that are FCC approv ed for use with the RF400 series are: Mfg. [...]

  • Page 61

    Appendix H. Distanc e vs . Antenna G ain, Ter rain, an d Other F actors H-5 As mentioned before, free space conditio ns are the ideal, but seldom actually seen. The higher the antenna height relative to the terrain in the line of sight path, the closer to free space conditions. Antenna height is ever ything! Here are some additional propagation e f[...]

  • Page 62

    Appendix H. Distanc e vs . Antenn a Gain, Ter rain, and Other F actor s H-6 Here is a tabl e which gives calculated path loss (Lp) valu es at 900 MHz for the 2 nd , 3 rd , and 4 th pow ers of dis tance; the equations (for 915 MHz) are: Lp ( 2 nd power) = 95.8 + 2 0 × log ( d ) dB (d in miles) Lp ( 3 rd power) = 95.8 + 3 0 × log ( d ) dB (d in mil[...]

  • Page 63

    Appendix H. Distanc e vs . Antenna G ain, Ter rain, an d Other F actors H-7 Use –107 dBm for Pr, solv e for Lp: Lp = 135 dB Use the 3 rd to 4 th power tabl es: Range fro m ~9 (4 th po w er) to ~22 (3 rd power) mil es Exampl e #2 Base has MaxRad BMOY8905 Yag i, with 50’ of LMR195 cable on a 30’ tower, als o a lightening protection devi ce with[...]

  • Page 64

    Appendix H. Distanc e vs . Antenn a Gain, Ter rain, and Other F actor s H-8 Thi s is a b lank pa ge.[...]

  • Page 65

    I- 1 Appendix I. Phone to RF400 Series Where a phone to R F400 Base is desired, the following configurations will provide P oint-to-Point or Point-t o-Multipoint c ommunicati ons. To have a bas e datalogger i n this confi guration requires that another R F400 be added at the base. 1. HARDWARE REQUIREMENTS a. RF400s b. COM210 c. PS512M (or CH 512R a[...]

  • Page 66

    Appendix I. Ph one to RF4 00 Series I-2 c. Phone Modem 1) Baud Rat e – 9600 2) Modem Pi ck List – per PC ’s phon e modem 3) Extra R esponse Time – 2000 ms d. Datalogger – Dialed U sing Ph one # at Base si te RF400 C ONFIGURATION a. Base RF400 1) Active Interf ace: “COM2xx to RF400” 2) AT Co mmand (Attention) Character: “-“ 3) All [...]

  • Page 67

    Appendix I. Ph one to RF4 00 Series I-3 PC208W S ETUP a. Network Map COM1 Modem1 Generic1 CR10X _1 CR10X _2 b. COM port - default settin gs c. Phone Modem 1) Baud Rat e – 9600 2) Modem Pi ck List – per PC ’s phon e modem 3) Extra R esponse Time – 2000 ms d. Generic Modem 1) Dialed Using phone # at base s ite 2) √ Make D TR Act ive a nd ?[...]

  • Page 68

    Appendix I. Ph one to RF4 00 Series I-4 FIGURE I-1. LoggerN et Point- to-Mult ipoint S etup 4. HARDW ARE After conf iguring L oggerNet or PC208W an d the RF 400s you are ready to set up ha rd ware. The PS5 12M null -mod em co nnec tors ( it’s no t impo rta nt which conn ector goes to wh ich unit) conn ect via SC12 cables to the COM210 and t he ba[...]

  • Page 69

    J- 1 Appendix J. Monitor CSAT3 via RF400 Series Procedure for ins talling a pai r of RF400 se ries spread spectrum radios for monitoring a CSAT3 sys tem at a distan ce. This function h as tr aditionally been implemented b y running a short haul modem cabl e between CS AT3 and PC. HARDWARE REQUIREMENT S • Two RF400s (moun ting bracket option avail[...]

  • Page 70

    Appendix J. Moni tor CSAT 3 via RF 400 Ser ies J-2 (5) Select “1” for “Standard Setup” an d configure the following (a) Active Interf ace – leave at default “Auto Sense” (b) Netw ork Address – can be def ault “0” if n o neighboring RF400 networks are operatin g; otherw ise choose a different netw ork address (see R X LED Test be[...]

  • Page 71

    Appendix J. Moni tor CSAT 3 via RF 400 Ser ies J-3 (2) Remote station (a) Connect 12 V power su pply to RF400 (can be either 120V A C adapter or 12V F ield Pow er Cabl e) (b) Connect 9 pin mal e to 9 pin male nu ll-modem cabl e from CSAT3 RS- 232 connect or to RF400’s RS-232 connector. (c) You are ready to start taking measurements TROUBLESHOOT I[...]

  • Page 72

    Appendix J. Moni tor CSAT 3 via RF 400 Ser ies J-2 This is a blank page.[...]

  • Page 73

    K-1 Appendix K. RF400/RF410 Pass/Fail Tests This appen dix describes a meth od to function ally test RF 400/RF410 sy stem componen ts including: • PC CO M port • SC12 serial cable • RF400/ RF410 • RF400/ RF410 An tenna Hardware/Software Requ ired 9 PC w ith one availabl e COM port 9 Terminal Program (HyperTerminal TM or Procom m TM ) 9 Two [...]

  • Page 74

    Appendix K. RF40 0/RF410 Pass/Fai l Tests K-2 (d) Emulation: TT Y (e) ASCII (f) COM1 (or any available COM port) With so me ve rsio ns of H yper Te rminal TM a fter changing a sett ing it is necessary to do a “Call Disconn ect” (or “Disconnect”) followed by a “Call Connect” (or “Call”) for the new settin g to register. (2) Connect a[...]

  • Page 75

    Appendix K. RF40 0/RF410 Pass/Fai l Tests K-3 TESTING RF40 0/RF410s After verifying the functionality of the terminal program and the integrity of the serial cable and COM port, procee d as follows: (1) Connect 12V power to an RF400/RF410. This can be from an AC adapter (Item # 1422 0 or Field P ower Cabl e (Item # 14291) w ith 12V battery pack att[...]

  • Page 76

    Appendix K. RF40 0/RF410 Pass/Fai l Tests K-4 (9) Make sure t hat no antennas are att ached to the RF400/R F410s (10) Label t he other RF400/ RF410, “Rem ote” (11) Insert jumper into th e Remote RF400/ RF410’s RS-232 conn ector pins 2 and 3 (us ing a U-shaped portion of a paper clip) allow ing data received from base RF400/R F410 to be transm[...]

  • Page 77

    Appendix K. RF40 0/RF410 Pass/Fai l Tests K-5 (b) Choose an open area free of larg e 2 metal objects w ithin 10 feet of the RF400/R F410s (can be i ndoors or out doors). (c) Attach a 1/ 4 wave omni ant enna (Item # 14310) t o base RF400/R F410 (d) Set u p remote RF 400/RF410 w ith NO ante nna (e) Separate R F400/RF410s by 5 f eet (f) Type 8 g roups[...]

  • Page 78

    Appendix K. RF40 0/RF410 Pass/Fai l Tests K-6 FIGURE K-3. 3 d Bd 900 MHz Colline ar Omni Antenna (d) Set u p remote RF400/ RF410 w ith NO antenn a and with antenna connector 20 i nches above f loor. (e) Arrange antenn a distance apart according to following table. TABLE K-1. 9 00 MHz Gain Antenna Test Di stances Antenna Gain Over ¼ Wave Power Rati[...]

  • Page 79

    L-1 Appendix L. RF400/RF410 Average Current Drain Calculations For rem ote sites with tight power bu dgets due to s olar or battery power supplies, the following will help determine average current consumption. The RF400/R F410’s averag e current drain i s based on: • Standby mode of RF 400/RF410 • Data collection interval • Number of data [...]

  • Page 80

    Appendix L. RF400/RF41 0 Av erage Cur rent Dr ain Calc ul ati ons L-2 The base RF400/ RF410’s t otal average curren t (It) can be calculated over an interval (T) as follows: It = Is + Ih + Iq + Ir + Ii Is = {table value} REMOT E The average curren t drain of a remote RF400/RF410 bein g collected on schedul e has 4 contri butors: 1) The STANDBY AV[...]

  • Page 81

    Appendix L. RF400/RF41 0 Av erage Cur rent Dr ain Calc ul ati ons L-3 EXAMP LE #1 (Remote RF 400/RF410 in default stan dby mode) There is a Poin t-to-Poin t system with base RF400/RF 410 and remote RF400/R F410. The remote station senses weather conditions and sends lo w- resolution data to final sto rage. The base station collects 1 0 data points [...]

  • Page 82

    Appendix L. RF400/RF41 0 Av erage Cur rent Dr ain Calc ul ati ons L-4 EXAMP LE #2 (Base RF400/RF 410 in defa ult stan dby mode) The base RF400/RF410 in th e above exam ple does more receiving and les s transm itting than the rem ote RF400/RF410 s o you migh t expect less averag e current drain, however, the amount of data being transmitted per minu[...]

  • Page 83

    Appendix L. RF400/RF41 0 Av erage Cur rent Dr ain Calc ul ati ons L-5 EXAMP LE #3 (Base RF400/RF 410 in “< 0.4 mA, 8 sec Del ay” standby mode) The RF400/R F410s in th is example are confi gured for the l owest possibl e average standby mode current (Advanced Setup Men u selection 7). The same amount and f requency of data are collected as in[...]

  • Page 84

    Appendix L. RF400/RF41 0 Av erage Cur rent Dr ain Calc ul ati ons L-6 EXAMP LE #4 (Remote RF 400/RF410 in “<0.4 mA, 8 sec D elay” stan dby mode) The RF400/R F410s in th is example are confi gured for the l owest possibl e average standby mode current (Advanced Setup Men u selection 7). The same amount and f requency of data are collected as [...]

  • Page 85

    Appendix L. RF400/RF41 0 Av erage Cur rent Dr ain Calc ul ati ons L-7 EXAMP LE #5 (Base RF400/RF 410 in defau lt “<4 mA , 1 sec Delay” st andby mode) The RF400/RF 410s in th is example are configured f or the default average standby mode current. The sam e amount of data (10 data points ) are collected as in Example 1, h o wever the fr equen[...]

  • Page 86

    Appendix L. RF400/RF41 0 Av erage Cur rent Dr ain Calc ul ati ons L-8 EXAMP LE #6 (Base RF400/RF 410 in “< 0.4 mA, 8 sec Del ay” standby mode) The RF400/R F410s in th is example are confi gured for the l owest possibl e average standby mode current (Advanced Setup Men u selection 7). The same amount of data are collected as in Example 1, how[...]

  • Page 87

    Appendix L. RF400/RF41 0 Av erage Cur rent Dr ain Calc ul ati ons L-9 EXAMP LE #7 (Remote RF 400/RF410 in “<0.4 mA, 4 sec Cy cle” standby m ode ) The RF400/R F410s in th is example are confi gured for the l owest possibl e average standby mode current (Advanced Setup Men u selection 7). The same amount of data are collected as in Example 1, [...]

  • Page 88

    Appendix L. RF400/RF41 0 Av erage Cur rent Dr ain Calc ul ati ons L-10 Thi s is a b lank pa ge.[...]

  • Page 89

    Thi s is a b lank pa ge.[...]

  • Page 90

    Campbell Scie ntific Com panies Campbell Scientific, Inc. (CS I) 815 West 1 800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campb ellsci.com Campbell Scientif ic Africa Pty. Lt d. (CSAf) PO B ox 24 50 Somers et West 7129 SOUTH AFRICA www.csafrica.co.za sales@csafrica.co.za Campbell Scientific Au st ralia Pty . Ltd. (CSA) PO B ox [...]