Go to page of
Similar user manuals
-
Air Conditioner
Carrier 48GS(N)018-060
8 pages 0.6 mb -
Air Conditioner
Carrier ASPAS1CCA015
52 pages 4.21 mb -
Air Conditioner
Carrier 42C
72 pages 14.36 mb -
Air Conditioner
Carrier 48PM16---28
11 pages 0.91 mb -
Air Conditioner
Carrier 38GF
12 pages 1.52 mb -
Air Conditioner
Carrier 38CMC
2 pages 0.02 mb -
Air Conditioner
Carrier 48EW
118 pages 6.36 mb -
Air Conditioner
Carrier 48/50P5030-100
16 pages 2.72 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Carrier 00EFN900003000A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Carrier 00EFN900003000A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Carrier 00EFN900003000A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Carrier 00EFN900003000A should contain:
- informations concerning technical data of Carrier 00EFN900003000A
- name of the manufacturer and a year of construction of the Carrier 00EFN900003000A item
- rules of operation, control and maintenance of the Carrier 00EFN900003000A item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Carrier 00EFN900003000A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Carrier 00EFN900003000A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Carrier service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Carrier 00EFN900003000A.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Carrier 00EFN900003000A item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Manufacturer reserves the right to disco ntinue, or change at any time, specifications or de signs without notice and without inc urring obligations. Catalog No . 04-53300012-0 1 Printed in U .S.A. Form 30XA-7SI Pg 1 1-07 Replaces: New Book 2 Ta b 5 c Installation Instr uctions P ar t Numbers 00EFN900 003000A, 00EFN900003100A CONTENTS SAFETY CONSID[...]
-
Page 2
2 Table 2 — Accessory Pac kage Content s Choose a space that can support the weight of the cooler and economizer with service clearances and area for refrigera nt piping. Field-supplied piping must be limited to less than 50 lineal ft (15.25 m) or 75 equivalent ft (22 m) in length. Suction and liquid line risers must be limited to less than 15 ft[...]
-
Page 3
3 ECONOMIZER S UCTION S ERVICE VA LV E 3 0X A REMOTE COOLER IND OO R L OC AT I O N ECONOMIZER S UCTION S ERVICE VA LV E REMOTE COOLER 3 0XA IND OO R L OC AT I O N 15 FT MAX ECONOMIZER S UCTION S E R VICE V A L VE REMOTE COOLER 3 0X A INDOOR LOCA TION 15 FT MAX Fig. 1 — 30XA Unit and Cooler Level, Piping Pa rallel (Single Circuit Shown) Fig. 2 —[...]
-
Page 4
4 INST ALLA TION 1. Inspect package contents for missing or damaged parts. File a claim with the shipping agency if parts are damaged and notify your loca l Carrier representative if any item is missing. 2. Determine the new location for the cooler . Ensure that the new location supports the cooler and economizers weights and that there is enough r[...]
-
Page 5
5 Table 4A — Refrigeration Line Sizes (English) Table 4B — Refrigeration Line Sizes (SI) Table 5 — Cooler and Economizer Weights 30XA UNIT SIZE SUCTION LINE DOUBLE SUCTION RISERS COOLER LIQUID LINE CONDENSER LIQUID LINE ECONOMIZER LINE Circuit A Circuit B Circuit A (in.) Circuit B (in.) Riser A (in.) Riser B (in.) Riser A (in.) Riser B (in.) [...]
-
Page 6
6 S IDE VIEW BOTT OM VIEW 1 3 /16 (20) 1/2 (1 3 ) 10-2 3 / 3 2 (272) 11 8 -1 3 /16 ( 3 017) 52-1/4 (1 3 27) 52-1/4 (1 3 27) 2 3 -1/ 3 2 (5 8 5) 15-5/16 ( 38 9) 64 (1625) 15-5/16 ( 38 9) 45-1/4 (1149) 15-5/16 ( 38 9) 19-21/ 3 2 (499) DET AIL A S CALE 2:1 TYP 6 PLACE S S EE DET AIL A Fig. 4A — 30XA080-120 Cooler Dimensions Fig. 4B — 30XA140, 160 [...]
-
Page 7
7 S IDE VIEW BOTT OM VIEW 1/2 (1 3 ) 1 3 /16 (20) 11- 3 /16 (2 8 4) 119-9/ 3 2 ( 3 0 3 0) 52-1/4 (1 3 27) 25-1/16 (6 3 6) 52-1/4 (1 3 27) 1 8 - 3 / 8 (466) 57 (144 8 ) 1 8 - 3 / 8 (466) 52-1/4 (1 3 27) 1 8 - 3 / 8 (466) 22-11/16 (576) DET AIL A S CALE 2:1 TYP 6 PLACE S S EE DET AIL A S IDE VIEW BOTT OM VIEW 1/2 (1 3 ) 1 3 /16 (20) 2 (50) 11-7/16 (2[...]
-
Page 8
8 S IDE VIEW END VIEW T OP VIEW 3 0- 3 / 8 (770) 22-7/ 8 (5 8 1) 2 3 -1/2 (59 8 ) 7-7/ 8 (200) 2 x Ø 7/16 (11) 29- 3 / 8 (746) 6-1/2 (166) 7/16 (12) 5/ 8 (17) 7/16 (11) 7/ 8 (21) 7/16 (11) 7/ 8 (21) 7-7/ 8 (256) 24-1/4 (611) 3 0- 3 /4 (7 8 1) 2 3 -1/ 3 2 (5 8 5) 4 x Ø 7/16 (11) 29- 3 / 8 (746) 8 - 3 /4 (222) 5/ 8 (17) 7/16 (12) 2-1/4 (56) S IDE V[...]
-
Page 9
9 Fig. 6 — Typical Cooler Piping-Cool er Side View ( 30XA140, 160 Shown) NO TES: 1. Circuit A uses steel suction piping. 2. Circuit B uses copper suction piping. 30 4518 a30-4518 CUT 4 ( S UCTION LINE) S UCTION PRE SS URE TRAN S DUCER (HIDDEN) S UCTION PRE SS URE TRAN S DUCER (HIDDEN) CUT 2 (COOLER LIQUID LINE) CUT 1 (LIQUID LINE) CUT 3 (ECONOMIZ[...]
-
Page 10
10 Remote Cooler and Economizers Installa- tion — Install the cooler an d economizers in a remote location by following this procedure: NOTE: Throughout the Remote Cooler and Economizers Installation steps, the two acces sory package part no. (00EFN900003000A, 00EFN900003100A) have been short- ened to 3000A and 3100A. When a specific part is refe[...]
-
Page 11
11 12. Using the accessory-supp lied M6 screws (3000A or 3100A: Item 6), install the accessory-supplied junction box (3000A or 3100A: Item 5) at the desired location where the entering and leaving water thermistor cables can be conveniently spliced. One or two knockouts can be used. Follow all local codes. Remove one knockout from the junction box [...]
-
Page 12
12 Table 6 — Materials Required for Ste el Piping Flange Connections LEGEND *Copper connection. UNIT SIZE COOLER PIPE FLANGE CONNECTION FL EX CONNECT OR FLANGE CONNECTION Circuit A Circuit B Circuit A Circuit B 140 Field supplied: ASME B16.9 Stub End 4 in. (102 mm) Accessory su pplied: Compressor Flange Gasket (3000A: Item 15), Loose Pipe Flange [...]
-
Page 13
13 Table 6 — Materials Required for Steel Pip ing Flange Connect ions (cont) LEGEND Table 7 — Additional Refr igerant Charges Requir ed UNIT SIZE COOLER PIPE FLANGE CONNECTION FLEX CONNECT OR FLANGE C ONNECTION Circuit A Circuit B Circuit A Circuit B 280 Field supplied: ASME B16.9 Stub End 4 in. (102 mm) Accessory supplied: Compressor Flange Ga[...]
-
Page 14
14 TO 30X A B RED . TEE 90 DEGREE STR ELLS FROM COOLER 45 DEGREE STR ELLS A 3 0XA PRE SS URE RELIEF VA LV E S (FIELD- S UPPLIED) ECONOMIZER LINE LIQUID LINE ( 3 0XA TO ECONOMIZER) MANUAL S HUTOFF V AL VE FLANGE CONNECTION S UCTION LINE MANUAL S HUTOFF VA LV E FLANGE CONNECTION COOLER LIQUID LINE (ECONOMIZER TO COOLER) COOLER ECONOMIZER NO TE: All s[...]
-
Page 15
15 A S ME B16.9 S TEEL S TUB END (FIELD- S UPPLIED) PIPE FLANGE (ACCE SS OR Y - S UPPLIED , S EE T ABLE 6) MOUNTING BRACKET EXI S TING FLANGE ON FLEX CONNECT OR A T 3 0XA BA S E UNIT 8 HOLE S 1 (25) EQU ALL Y S P ACED 1 EXTRA HOLE M16 7-7/ 8 (200) 22.5° 45.0° 8 -1/2 (215.9) Fig. 10 — Unbolt Portion Betwee n Flex Connector and Cooler (30XA140, 1[...]
-
Page 16
Manufacturer reserves the right to disco ntinue, or change at any time, specificatio ns or designs without notice and without inc urring obligations. Catalog No . 04-53300012-01 Printed in U .S.A. Form 30XA-7SI Pg 16 3-07A 1-07 Replaces: New Book 2 Ta b 5 c Copy right 2007 Carrier Cor poration MAIN BA S E BOARD EWT EWT LW T LW T EWT EWT LW T LW T J[...]